Ask Experts Questions for FREE Help !
Ask
    SandyPTaylor's Avatar
    SandyPTaylor Posts: 1, Reputation: 1
    New Member
     
    #1

    Dec 13, 2009, 11:01 AM
    Pressurizing a jet pump pressure tank
    How much pressure should you pump into a bladder type pressure tank. Currently running on a 25/45 pressure switch. Describe method required to do same.
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #2

    Dec 13, 2009, 11:53 AM

    Simple. Turn off the breaker and drain the system pressure down to zero through the lowest level faucet you have. Set the pressure in the tank to 23# through the valve on top of the tank. Turn the breaker back on. Done.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Dec 13, 2009, 02:30 PM

    Let me explain the function of a bladder tank. Pressure and bladder tanks provide a air cushion that produces water pressure in your system so your pump doesn't kick on every time you draw a glass of water. A bladder tank has a neoprene membrane in the center. As the pump puts water into the bottom half of the bladder tank the membrane compresses the air in the top half. When the pressure reaches the cut off point in the control box the pump shuts down. However you still have between 40 to 50 pounds of pressure pushing the water out to your system. As the pressure drops in the tank when you make a draw the pump kicks on and everything starts over again.
    To check, take something metal and start rapping at the bottom of the tank and work upwards. You will hear a "clunk" in the bottom half full of water. On the upper half you should hear a "clink" because the upper half should have nothing but air in it. IF the sound doesn't change or changes close to to tank top then the bladder tank must be replaced. Your air setting on the tank should be 2 pounds UNDER the cut in point in the pressure control box. If your pressure control has a 20 PSI cut in and 40 PSI cut out the tank pressure should read 18 PSI. The bladder tank setting MUST be made with the pump off and the system bled down by opening a cold water faucet after you shut the system down at the breaker box. Hope this helps and thank you for rating my reply. Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Do I need to install a jet pump, a pressure tank and a holding tank? [ 6 Answers ]

I have a new home with nothing but the 1inch well pipe stemed through the cellar wall. My house is not on town supply line. Do I need to install a jet pump that goes to the pressure tank which then sends water ot a holding tank? Or is the pressure tank by itself all that I would need? Or a...

Pump without pressure tank! [ 20 Answers ]

Hey, I just saw a response to a question that is EXACTLY what I want to do but not sure how to size the pump etc. This was the response to the guys question of "Jet pump without pressure tank"... : Whoa You have a 1550 gal. holding tank. (This is a holding tank and not a pressure tank,...

Jet pump without a pressure tank [ 6 Answers ]

I have a 1550 gallon holding tank 4 feet from my jet pump by craftsman. The pump is 3 feet from the house. It is used as a cabin in which we use about 300 gallons one weekend out of the month. I was wondering if I have to use a pressure tank. I don't mind the pump kicking on each time we use...

Pressure tank on well pump [ 2 Answers ]

I just had a power outage and when the power came back on there was no pressure in the system, I think the pressure tank needs to be reset?

Well pump pressure tank [ 3 Answers ]

I am having problems with my pump. Most of the time when I turn the water on (flush the toilet, etc.) I hear a sort of nocking on the pipes. I believe my pump is turning on and off at a constant. My husband has replaced the box that has the voltage regulator and the capacitor in it. The capacitor...


View more questions Search