    slartibartfarst's Avatar
    slartibartfarst Posts: 1, Reputation: 1
    New Member
     
    #1

    Apr 1, 2008, 07:57 PM
    Pressure tank on well pump
    I just had a power outage and when the power came back on there was no pressure in the system, I think the pressure tank needs to be reset?
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    Apr 2, 2008, 04:04 AM
    Check the breakers in the electric panel. Turn them off, then back on to insure that they are reset.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Apr 2, 2008, 04:16 AM
    Quote Originally Posted by slartibartfarst
    I just had a power outage and when the power came back on there was no pressure in the system, I think the pressure tank needs to be reset?
    Harold's thinking loss of power while I'm thinking loss of pressure. Who's correct? Either way the pressure tank's not involved. If you've lost pressure and prime when the power went down then you have a faulty check valve that's allowing the pump to lose prime. Solution? Replace the check/foot valve. Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Pressure/bladder tank losing pressure? [ 11 Answers ]

Well, I have asked some questions about my plumbing before. So I am calling on you guys once again. I have a 52 gallon pressure tank/bladder tank made by wellsaver. I turn the water on and have good pressure for a few minutes then it basically goes dead with no pressure. I recently posted questions...

Well pump pressure tank [ 3 Answers ]

I am having problems with my pump. Most of the time when I turn the water on (flush the toilet, etc.) I hear a sort of nocking on the pipes. I believe my pump is turning on and off at a constant. My husband has replaced the box that has the voltage regulator and the capacitor in it. The capacitor...

Tank Pressure vs Pump Cut Out Pressure for Well [ 1 Answers ]

I am trying to increase my water system pressure to the minimum required 40 PSI to feed my reverse osmosis drinking water filter. However, the 33 gallon pressure tank for my well pump system says it is pre-charged at 30 PSI and that the cut in pressure for my pump should be set equal to that 30...


View more questions Search