    Pilot light won't stay on
    I bought a Kenmore power miser gas water heater in May of 2002 The
    First 3 years and 8 month's I had the waterheater I did not have 1 problem.
    In January of 2006 the light went out and tried to light it. It stayed
    Lid until I released the button and it went out. I called sears
    Because it is a Kenmore water heater and someone came and replaced the
    Thermocouple. About 6 month later that year it went out again. I lid it this
    Time and it worked fine for over a year. 2 weeks ago on the 12th it went out. It lid back up enough to warm the water then went out again. I called a differnet plumbing company and they said the old thermocouple was loose and just replaced it to be safe. So in
    The fist 4 years no problems and in the last 2 years I replaced the
    Thermocouple twice and it went out 3 times total. I have paid for 2 service
    visits and still feel there is a bigger problem? What do you think?
    hixton's Avatar
    hixton Posts: 146, Reputation: 5
    Junior Member
     
    #2

    Oct 26, 2007, 04:35 AM
    Did they tightened the bottom of the pilot tube it sometimes gets loose and leaks causing the cold junction on the thermocouple to open also cleaning the burner area with a vacuum helps but check the bottom of the pilot to make sure there's not a little flame no the nut just below if there is try tighting
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #3

    Oct 26, 2007, 05:32 AM
    It is really disappointing after a couple of professionals have worked on it, you are here looking for help. Make sure the thermocouple is in the flame of the pilot light. Be careful to replace any covers. They can help keep a draft from blowing the flame away from the thermocouple. Although replacing the thermocouple is often a cheap, easy fix, no way should you have needed a new one ever year.
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #4

    Oct 26, 2007, 07:39 AM
    Has anything changed in your home around the time the problem started? Maybe a new fireplace, bathroom fan, attic pull down stairs case? Labman is correct, they just don't fail this quickly so maybe there are other unidentified issues leading to the problem.
    dshimank's Avatar
    dshimank Posts: 2, Reputation: 1
    New Member
     
    #5

    Oct 26, 2007, 12:32 PM
    Nothing has changed at all. The last that came said that the old thermocouple was loose and maybe that is what it is causing this problem. He replaced it to a new one just in case.
    Every plumber I speak with keeps saying that it's the thermocouple.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #6

    Oct 26, 2007, 12:52 PM
    Look out next to the gas meter. Is there a tee looking down with a short piece of capped pipe coming out of the branch of the tee? If so then this is a drip loop. Its function is to collect moisture and condensate before it can get into your system and extinguish the pilot lite. This pipe can fill up from time to time and allow moisture to enter along with the gas. This could be the source of your problem. The4 solution would be to shut the gas off at the meter and drain the drip loop. Good luck, Tom
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #7

    Oct 26, 2007, 05:56 PM
    What would happen if you didn't have a drip loop either at the meter or at the water heater?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #8

    Oct 27, 2007, 04:58 AM
    Wouldn't that affect the burner too? What would happen if you didn't have a drip loop either at the meter or at the water heater?
    If moisture entered along with the gas it would get to the pilot lite first. If there4 were no drip loop then moisture in the gas line would not be trapped.
    Regards, tom
    davedp1's Avatar
    davedp1 Posts: 1, Reputation: 1
    New Member
     
    #9

    Sep 1, 2009, 08:58 PM
    I had the same problem with the pilot going out. I pulled my hair out trying to figure it out. I finally switched out the thermocouple with a new one from OSH. It was about $8. The difference was, the replacement did not have the TCO unit in line. The TCO looks like a little disc and it has a "160" stamped on it. This little thing is supposed to turn the gas off if the air temp in the sealed unit hits 160 degrees as a safety device. I think all of the replacement parts from Sears have the TCO also, and it goes bad fast. The new one from OSH (without the TCO) has been working now for about a week. Keeping the fingers crossed.
    afaroo's Avatar
    afaroo Posts: 4,006, Reputation: 251
    Ultra Member
     
    #10

    Sep 1, 2009, 09:13 PM

    Hello Dave,

    Welcome to this web site it is great to have you, and appreciates for sharing your experience with us, this is old post from 2007, I am sure his problem is fixed, Thanks.

    Regards,
    John
    thetruthonly's Avatar
    thetruthonly Posts: 1, Reputation: 1
    New Member
     
    #11

    May 8, 2012, 04:29 PM
    IT CAN be a breathing problem related to clogged filters, BUT ALSO
    Can be FIXED by reducing the gas pressure to the unit by slightly
    Turning the knife switch so the gas isn't so "full blast". The pilot light
    Actually goes out when the unit turns off and stops the heating and the
    Air flow then is very violent. Less violent flames, less air needed, stays lit
    With less gas pressure. Does not effect heating really.
    Yes, and clean filters too! THIS WORKS AND IS SOOOOO EASY!
    afaroo's Avatar
    afaroo Posts: 4,006, Reputation: 251
    Ultra Member
     
    #12

    May 8, 2012, 10:16 PM
    Hello Thetrueonly,

    Welcome to this web site it is great to have you, and appreciates for sharing your experience with us, this is old post from 2007, I am sure his problem is fixed, Thanks.

    Regards,
    John
    mextexdad's Avatar
    mextexdad Posts: 3, Reputation: 1
    New Member
     
    #13

    Dec 30, 2012, 11:48 AM
    Get rid of the cat!
    Seriously, the new gas water heaters only source of air to keep the pilot lit is through a screen under the bottom. This screen can become clogged with cat ((or dog) hair or even dust bunnies. Clean periodically with brush and or vacuum.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Water heater pilot light will not stay lit [ 43 Answers ]

The pilot light on my gas water heater will not stay lit. I can light the pilot light, but when I release the valve, it goes out.

My pilot light won't stay lit [ 6 Answers ]

Help,I have two problems.. My upstairs furnace pilot light will light,and after holding down the pilot button for about 3-4 minutes(it says one minute,but it won't stay lit after only one)it stays,but will go out again in a day or two... The furnace for the downstairs won't light at all.. I can't...

Does putting gas hot water heater dial on PILOT put pilot light out? [ 5 Answers ]

My gas hot water heater dial has OFF to the left, PILOT in the middle and ON to the right. If we are going away and want to not have the water heated can we just turn the dial to PILOT and the flame will stay lit but just won't heat the water or does the flame go out completely and then PILOT would...

Leaky water heater, now pilot light will not stay lit [ 1 Answers ]

We had a substantial leak in our water heater, to the point where the insulation was soaked around the tank. We had that fixed by a plumber but now the pilot light will not stay lit. it will light, and seconds after turning the heat back to on it will go out. It has now been over 24 hours since...


View more questions Search