Old May 1, 2008, 07:39 PM
Phil23314
New Member
Phil23314 is offline
 
Join Date: May 2008
Posts: 2
Phil23314 See this member's comment history on his/her Profile page.
Outdoor underground ejector pump & pit venting

I recently purchased a 30 yr. old house that has a pit & ejector pump on the output side of the septic tank. It is buried approx. 1 ft. I recently dug it up for the first time to investigate what I thought was a bad/intermittent float valve causing the pump to be operating constantly. My suspicion was confirmed.

While looking at the setup it occurred to me that the pit has no direct vent to the outside. Therefore it has to get vented back through the house plumbing. I believe this is called wet venting. Then it occurred to me that this might be the cause of strange problem we've been having on occasion, which is a lavatory trap that gets siphoned dry (you can hear the "pop-pop" of the siphoning/sucking action). Additionally, when this happens, the water level in the toilet bowl gets lower.

My question is: Does even an outdoor, underground pit need to be directly vented to the outside?

Thanks,
Phil

Reply With Quote
 
     

Answers
 
 
Old May 6, 2008, 06:40 PM   #2  
Ultra Member
doug238 is offline
 
Join Date: Feb 2007
Location: atlanta metro area
Posts: 1,555
doug238 See this member's comment history on his/her Profile page.
being on the downhill side of the septic tank i am guessing you drainfield is on high ground or relocated to a different area. the house drain and venting should be plenty.
  Reply With Quote
 
     
 
 
Old May 7, 2008, 07:07 AM   #3  
Senior Plumbing Expert
speedball1 is online now
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,875
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
My question is: Does even an outdoor, underground pit need to be directly vented to the outside?
Yes! The pit's sealed and MUST have a dedicated vent whether it's inside or outside. The tank should have a sealed opening that was designed to run a vent out of. A ejector pit vent should NEVER be tied back into the house venting system.Good luck, Tom

Comments on this post
rick4747 agrees: right on the money 1
  Reply With Quote
 
     
 
 
Old May 8, 2008, 05:01 AM   #4  
Ultra Member
doug238 is offline
 
Join Date: Feb 2007
Location: atlanta metro area
Posts: 1,555
doug238 See this member's comment history on his/her Profile page.
do research on a lift station. your situation is more like a lift station than a sump situation.
  Reply With Quote
 
     
 
 
Old May 8, 2008, 05:07 AM   #5  
Senior Plumbing Expert
speedball1 is online now
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,875
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by doug238
do research on a lift station. your situation is more like a lift station than a sump situation.
Doug, A sump pump was never mentioned and a lift station describes a ejector pit, which is what he has. The question was about a vent which has already been answered. regards, tom
  Reply With Quote
 
     
 
 
Old May 8, 2008, 05:14 AM   #6  
Ultra Member
doug238 is offline
 
Join Date: Feb 2007
Location: atlanta metro area
Posts: 1,555
doug238 See this member's comment history on his/her Profile page.
tom, the situation is a 30 year old home, no vent on pump on downhill side of septic system. it never had a vent because it is a lift station for the septic system. being on the downhill side of the septic tank it can not possibly affect the lavatory trap on a house system that is vented. he is looking at this like a sump pump situation in a sealed area and that situation simply does not apply. a typical lift station does not require an individual vent.
  Reply With Quote
 
     
 
 
Old May 8, 2008, 05:25 AM   #7  
Senior Plumbing Expert
speedball1 is online now
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,875
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
a typical lift station does not require an individual vent.
If it's sealed it does. And a ejector pit's sealed, otherwise it's called a sump pump with a open pit.
  Reply With Quote
 
     
 
 
Old May 8, 2008, 01:31 PM   #8  
New Member
Phil23314 is offline
 
Join Date: May 2008
Posts: 2
Phil23314 See this member's comment history on his/her Profile page.
Thanks for the responses folks.

I can't really say if the pit ever had a vent in the past or not. When I dug it up, I could see that the pit lid had been replaced with one that was home-made out of 1/2" PVC board material. If it did have a vent before, that person did not put one back on.

The drain field dist. box is approx. 250 ft. from the tank/pit. Our lot is pretty flat so I'm just assuming they had to pump it due to not being able to provide a gravity feed.

For what it's worth, I went ahead & installed a vent pipe in the pit cover before shoveling the dirt back in. The pit is about 15 ft' away from the house & windows. I figured if it started smelling, I'd install a charcoal filter.

Another problem that this system had was the lack of an alarm, which I installed. Also, I determined that the old float switch (which was working intermittantly) was set too high. It's turn on level was up so high that the effluent was allowed to fill the tank (almost to the brim) before turning the pump on. Basically, the effluent would be half way up the pit's inlet opening before things got drained. Maybe this was also part of my lavatory trap problem. It's only been about a week, but so far I haven't seen/heard the trap go dry.

Thanks again.

Phil
  Reply With Quote
 
     
 
 
Old May 8, 2008, 03:01 PM   #9  
Senior Plumbing Expert
speedball1 is online now
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,875
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
If the pit had a wooden cover with dirt on top then it was "kinda sealed" . You did the right thimg in venting it.
Let me know if things are still working OK. Tom

Comments on this post
Phil23314 agrees: Tom's comments seemed to make sense. I appreciated his thoughts.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
sewage pump/ejector pump
(2 replies)
Ejector Pit Venting - Will this work?