Ask Experts Questions for FREE Help !
Ask

oil burner with low hot water pressure

Asked Nov 30, 2011, 11:10 AM — 3 Answers
I have an oil hot water system, the hot water running through the house has low pressure. where do i find the heater coil to see if it needs to be cleaned or replaced

3 Answers
massplumber2008's Avatar
massplumber2008 Posts: 10,550, Reputation: 5092
Plumbing Expert
 
#2

Dec 1, 2011, 05:14 AM


Hi Jo_EL

The tankless coil is immersed inside the boiler itself...only way to check it is to isolate it and then run a weak acid solution through it to try to breakdown the mineral deposits that may have built up and is clogging things up. This is usually best left to a plumber/oil burner technician...

With that being said, the first thing to check in cases like this is going to be the shutoffs at the cold water INLET and at the hot water OUTLET (if there are any shutoffs on the outlet at all) of the tankless coil. Here, if there is a boiler drain at the tankless coil you can open that full open and see what the pressure/volume looks like. If you have significant pressure then, most likely, the issue is after the coil (at another shutoff), or it could be that the coil is clogged on the outlet side only...that kind of stuff.

Anyway, the only way to find out what is going on is to break this down into manageable steps. Check the easy stuff, and then check the harder stuff like cutting shutoffs out and replacing with new shutoffs, and then finally, when all avenues have been exhausted, you try an acid wash on the coil (tricky, like I said) and see if that fixes all.

If all else fails you either get a replacement tankless coil or you opt. in for a water heater or a strorage tank and be done with this!

Back to you...

Mark
Helpful  (1)
Jo_EL's Avatar
Jo_EL Posts: 2, Reputation: 10
Junior Member
 
#3

Dec 1, 2011, 06:05 AM
i was surprised when the tech. came out to clean the oil burner, i watched him vacuum it and replace the nozzle and the oil filter, i asked him about lousy hot water pressure, he blamed it on build up in the pipes and turned my water temp up to 180 degrees...never mentioned the coil. i remembered after he left that i did have an acid wash done about 3 yrs. ago. can it be done again? or is that too much acid on the coil.
Helpful
massplumber2008's Avatar
massplumber2008 Posts: 10,550, Reputation: 5092
Plumbing Expert
 
#4

Dec 1, 2011, 10:25 AM


You could see if someone will acid wash the coil again...really have nothing to lose because if an acid wash does the coil in, the coil was shot anyway...

In terms of the 180 degree temp. increase, I don't like that UNLESS you have a mixing valve (see image) at the outlet of the tankless coil? Let me know on that, OK?

Mark
Attached Images
 
Helpful  (1)

Not your question? Ask your question View similar questions

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search

Add your answer here.

Remove Text Formatting

Undo
Redo
 
Decrease Size
Increase Size
Bold
Italic
Underline
Align Left
Align Center
Align Right
Ordered List
Unordered List
Decrease Indent
Increase Indent
Insert Email Link
Wrap [QUOTE] tags around selected text
Wrap [CODE] tags around selected text
Wrap [HTML] tags around selected text
Wrap [PHP] tags around selected text
Wrap [YOUTUBE] tags around selected text
Notification Type:



Check out some similar questions!

Low hot water pressure in a oil burner [ 5 Answers ]

Over the last several months we have lost our hot water pressure in all of our showers and sinks. My neighbor said that he changed his coil in his boiler about 4 years ago because of the same problem. I know we have a hard water problem which I just bought a water softener which I am going to...

Low hot water pressure on a kitchen sink, good cold water pressure [ 4 Answers ]

I have a single faucet sink where the cold water pressure is fine and all other sinks have good hot and cold water pressure. I replaced the kitchen faucet two years ago along with new lines. As of late I'm getting very little hot water pressure along with having to run the water for about 10...

Oil Burner/Hot water Baseboard system. [ 0 Answers ]

Water pressure has a "red line" at 50lbs on the 2" OB pressure gauge. Lately pressure is down to almost zero after several days. There is a regulating value at the water supply line with a manual override to fill/increase the pressure. What is the normal pressure for this type of system? Is the...

Oil-burner doesn't continue heating hot water for water heater during warm weather [ 1 Answers ]

I have an oil-fired burner connected to a baseboard hot water heating system and the hot water heater. There are five zones for heating and one zone for the hot water heater. In the winter, having enough hot water is never a problem. However, when the weather gets warmer and the heating zone...

Low water pressure oil hot water heating system [ 1 Answers ]

How does one go about increasing water pressure in a baseboard heating system?


View more Plumbing questions Search