Question
 
 
#1  
Old Nov 5, 2005, 12:26 PM
bob2build
New Member
bob2build is offline
 
Join Date: Nov 2005
Posts: 2
bob2build See this member's comment history on his/her Profile page.
New basement plumbing

I am planning on putting a bathroom in the basement. My ejector pit currently services a floor drain into which runs condensate from the central air as well as water from the central humidifier. I would like to install a toilet, sink, and shower. Do these each need separate connections to the pit, or can I run one 3 or 4 inch drain for the toilet directly to the pit, and tie in the proposed 2 inch lines from the sink and shower into the larger toilet line?

Also, regarding venting, can all these tie into the existing vent from the pit?

Your help is greatly appreciated.
Bob

Reply With Quote
 
     

Answers
 
 
Old Nov 5, 2005, 03:28 PM   #2  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 14,477
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Hey Bob,

You ask,"can I run one 3 or 4 inch drain for the toilet directly to the pit, and tie in the proposed 2 inch lines from the sink and shower into the larger toilet line?"
yes you may. It will go like this. 4" ,or 3 if code allows from the toilet to the pit. The lavatory will tie into that and be vented by a separate vent,( this could be a "cheater vent") and the shower drain will tie into the lavatory drain and be wet vented by it. Note: You may not tie the lavatory vent back into the pit vent. It must have its own vent. Good luck, Tom
  Reply With Quote
 
     
 
 
Old Nov 6, 2005, 08:19 PM   #3  
New Member
bob2build is offline
 
Join Date: Nov 2005
Posts: 2
bob2build See this member's comment history on his/her Profile page.
Hey, thanks for the help. What exactly is a "cheater vent"?

My ejector pump is about 8 years old and working fine. But since I will be installing all this new input into the pit, would you replace the working pump with a new one? What is the life expectancy on an ejector pump? I'd hate to do all this work and have to replace the current one within a year.

Again, thank you.
Bob
  Reply With Quote
 
     
 
 
Old Nov 7, 2005, 05:42 AM   #4  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 14,477
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Good morning Bob,

"since I will be installing all this new input into the pit, would you replace the working pump with a new one?"
I'm a great believer in, "If it ain't broke don't fix it". I don't know what the life of a grinder pump is since I've never had to replace one.
A "cheater vent" is a spring loaded mechancal vent that is used when it's not feasible to run a outside vent. You can check them out at, http://www.studor.com/homeowners.htm Good luck, Tom
  Reply With Quote
 
     
 
 
Old Nov 9, 2005, 01:26 PM   #5  
New Member
handylady is offline
 
Join Date: Nov 2005
Posts: 1
handylady See this member's comment history on his/her Profile page.
From reading some other threads, I thought you couldn't use a studor vent on a system with an ejector pump. I'm asking because I'm about to finish my basement. The bathroom fixtures are vented to the roof as is the ejector pump (roughed in anyway), but I am not sure that my wetbar stub is vented. It may be tied to the vanity vent to the roof, but not sure?
  Reply With Quote
 
     
 
 
Old Nov 9, 2005, 02:52 PM   #6  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 14,477
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by handylady
From reading some other threads, I thought you couldn't use a studor vent on a system with an ejector pump. I'm asking because I'm about to finish my basement. The bathroom fixtures are vented to the roof as is the ejector pump (roughed in anyway), but I am not sure that my wetbar stub is vented. It may be tied to the vanity vent to the roof, but not sure?
Hi Lady,

You are correct. You can't use a "cheater vent" on a ejector pit. However if you will go back and read my reply, ( The lavatory will tie into that and be vented by a separate vent, this could be a "cheater vent" ) you will see I suggested using a "cheater vent" on the lavatory which is part of the bathroom group and not the vent that services the pit. As for your wet bar, if the ejector pit is vented to the out side you may vent the wet bar with a Cheater vent if you wish. Regards, Tom
  Reply With Quote
 
     


Thread Tools
Display Modes

 
Similar Sponsors

Similar Threads
Question Asker Forum Answers Last Post
Basement plumbing zgibson Plumbing 2 May 8, 2006 01:21 PM
basement plumbing throttlematch1 Plumbing 1 Feb 28, 2006 04:00 AM
basement plumbing Dirk Plumbing 1 Feb 2, 2006 11:30 AM
basement plumbing jih Plumbing 10 Feb 7, 2005 12:24 PM
Basement Plumbing fixit Plumbing 1 Jan 16, 2005 05:50 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 12:25 PM.