Ask Experts Questions for FREE Help!
Ask    ||    Answer
 
Advanced  
 

Ask QuestionsprogressAnswer QuestionsprogressBuild ReputationprogressBecome an Expert
 
Free Answers in 3 Easy Steps

Register Now
3 Steps

At Ask Me Help Desk you can ask questions in any topic and have them answered for free by our experts. To ask questions or participate in answering them you must register for a free account. By registering you will be able to:
  • Get free answers from experts in any of our 300+ topics.
  • Accept money for answers that you provide.
  • Communicate privately with other members (PM).
  • See fewer ads.

Home > Home & Garden > Plumbing   »   move toilet 2"closer to the wall

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Aug 1, 2009, 07:00 PM
litender
New Member
litender is offline
 
Join Date: Aug 2009
Posts: 6
litender See this member's comment history on his/her Profile page.
move toilet 2"closer to the wall

The previous owner of our house moved the wall behind the toilet back over 4" & put in a round toilet. I wanted to get an elongated bowl but it would stick out too far into the door way in such a small bathroom. So we bought a KOHLER Cimarron White Round Complete Toilet Model: 11465-0 to replace the old WC. After doing some research online I find out that as good as this WC flushes it leaves 'stuff' on the back of the bowl. My wife already informed me that I should have looked into this a bit more before buying it.
OH WELL, Stuff happens!

Since we have not even opened the box it will not be a problem to return it. I would really like to get an elongated ADA toilet. Can I use an offset flange & move the new bowl back 2"? (More if possible) Moving it back would allow an elongated bowl & not such a huge space behind the tank The current bowl waste line is 4 "PVC T straight down
about 9" into cast iron pipe. Off of the T is a PVC extension & the a rubber coupling to the original cast iron vent pipe.

Hopefully this description makes sense to someone besides me.

I know Toto makes an extension for their toilets, but a Toto is not in out current price range.

Thanks in advance for any & all input.
Lou

Reply With Quote
 
     

Answers
 
 
Old Aug 1, 2009, 07:40 PM   #2  
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 5,446
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
Hi Lou...

I need to know the measurement from the finished wall to the center of the toilet bolts (or the center of the closet flange).

If 12" to 14" (or more) then you can move the toilet back anywhere between 1.5" to 2" depending on which PVC offset flange you can get your hands on...see image.

If 14" from finished wall to the center of the toilet bolts then you are in ideal position to move the toilet back easily and end up purchasing any common 12" rough in toilet that you want (regular prices prevail).

If 12" from finished wall to center of toilet bolts then you could offset back no problem but then you would need a 10" rough in toilet and that is usually special order and costs extra money, for sure..

If 10" or less then you are stuck with what you have as they only make one or two 8" rough in toilets and they are just priced ridiculously!!...

Let us know if you have more questions on this...

MARK
Attached Images
 
  Reply With Quote
 
     
 
 
Old Aug 2, 2009, 08:16 AM   #3  
New Member
litender is offline
 
Join Date: Aug 2009
Posts: 6
litender See this member's comment history on his/her Profile page.
Mark,

WOW, thanks for the super quick reply.

The space from the wall to the center bolts is 15.5".
I thought I read someplace that there is a problem with leaking using offset flanges. But then again I've read so much info in the last few days that I feel like I was a kid again cramming for a test.

Lou
  Reply With Quote
 
     
 
 
Old Aug 2, 2009, 08:54 AM   #4  
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 5,446
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
Hi Lou:

The biggest problem with offset flanges is associated with the older cast iron type of offset flange where installing the OAKUM can be difficult due to the angle of the inside joint...

With PVC offset flanges there is absolutely no issues with leaking!

If you can find a 2" PVC offset flange that would put you at 13.5" off the finished wall which would be just perfect for a 14" rough in toilet...

MARK
  Reply With Quote
 
     
 
 
Old Aug 2, 2009, 01:48 PM   #5  
New Member
litender is offline
 
Join Date: Aug 2009
Posts: 6
litender See this member's comment history on his/her Profile page.
I tried to rate your answers but the system would not allow it.
  Reply With Quote
 
     
 
 
Old Aug 2, 2009, 02:04 PM   #6  
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 5,446
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
Not real important... But thanks for trying! Pop back anytime.

MARK
  Reply With Quote
 
     
 
 
Old Aug 2, 2009, 03:10 PM   #7  
New Member
litender is offline
 
Join Date: Aug 2009
Posts: 6
litender See this member's comment history on his/her Profile page.
Mark,
May I ask your opinion of the KOHLER Cimarron class5 ? I understand it flushes pretty good, but I'm concerned about the "fact" that I can't use a plunger if it does clog up.

Hope you have a magical week ahead.
lou
  Reply With Quote
 
     
 
 
Old Aug 2, 2009, 04:06 PM   #8  
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 5,446
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
Hi Lou:

I'm a big fan of toto toilets...then kohler toilets and then american standard toilets. I've only installed 2 cimarron toilets...didn't have any issues or complaints.

I did a quick review of the cimarron online and found as many complaints as I found approvals....so hard to offer much here.

All in all, I figure if you find a toilet that looks good and you like it then you will find a way to make it work for you. Hope that makes sense.

MARK
  Reply With Quote
 
     
 
 
Old Aug 4, 2009, 09:05 AM   #9  
New Member
litender is offline
 
Join Date: Aug 2009
Posts: 6
litender See this member's comment history on his/her Profile page.
Mark,
I'm going to ask you a (semi) dumb question. Is it feasible to move my toilet back to the wall using 2 degree bends not together as a 90 but kinda one turned opposite & then also use any offset flange. I have a 15.5" rough in & only a 12" toilet. Or am I thinking too much along the Rube Goldberg lines?

Again thanks in advance, I really appreciate your info,
Lou
  Reply With Quote
 
     
 
 
Old Aug 4, 2009, 11:20 AM   #10  
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 5,446
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
Not even close to semi. dumb...

You said you had about 9" from the flange to the rubber clamp below. Even if you use STREET 45s or street 22.5 degree fittings and an offset flange I don't think 9" will work....I don't even think it's close!

Maybe you can reduce the 4" to 3"...that would improve things. How much more room between the rubber clamp and the cast iron hub below it?? If you cut this lower and reduce to 3" you may be able to accomplish the 12". Let me know...

MARK

Comments on this post
litender agrees: Fast, smart & accurate responses
Attached Images
 
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
Outlet 11" from wall. Can I use a 12" rough-in toilet?
(2 replies)
Need to replace toilet, rough-in 20" from the wall, toilet has four mounting holes
(3 replies)
How can I move her closer?
(2 replies)
Can I move toilet to other side of wall and add a tub?
(0 replies)
Moving an existing toilet closer to the wall
(1 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 01:57 PM.