Luke warm temp from gas hot water heater

Asked Jan 14, 2008, 09:26 AM — 13 Answers
About 6 days ago, we suddenly only had luke warm water from all our hot water faucets. I called the hot water heater help line and they sent me a new thermostat. I had a friend (who is a pro) install the thermostat, and still no hot water. I can see the pilot is lit. I can hear a constant "roar" from the heater, which is supposed to be indicative of a build up of minerals and sediment in the tank, however none was noted when the t-stat was installed, and the tank was flushed at that time. The "tube" leading to the old t-stat was filled with gunk, so we assumed that was the problem. But still no hot water.
My tank is an energy saver, and is about 3- or 4 years old.

13 Answers
ballengerb1's Avatar
ballengerb1 Posts: 25,641, Reputation: 11296
Home Repair & Remodeling Expert
 
#2

Jan 14, 2008, 10:00 AM


You may have lost your dip tube so the cold fresh water is entering the tank at the top right where the hot is drawn out. Dip tubes fail, did you get any white, hard specs of crud when you flushed the tank? That could be part of the dip tube.
Helpful
Nytzsi's Avatar
Nytzsi Posts: 7, Reputation: 1
New Member
 
#3

Jan 14, 2008, 10:13 AM
Someone flushed the tank for me, so I didn't see the contents exiting. Are dip tubes easily replaced?
Helpful
ballengerb1's Avatar
ballengerb1 Posts: 25,641, Reputation: 11296
Home Repair & Remodeling Expert
 
#4

Jan 14, 2008, 10:18 AM


Not too hard but a lot depends on how your cold supply is connected. You need to remove the incoming cold supply pipe to the heater. That pipe could be held by a sweat fitting, dielectric union, galvanized or whatever, it must be removed to install a new dip tube. When you draw hot water for a few minutes do you hear the nain burner fire up and the exhaust tube will get too hot to tough?
Helpful  (1)
Nytzsi's Avatar
Nytzsi Posts: 7, Reputation: 1
New Member
 
#5

Jan 14, 2008, 10:50 AM
My heater is roaring all the time, I don't notice any sound getting any louder when drawing hot water.
I did forget to mention that the exhaust passes through the wall in my bedroom on the second floor (over the water heater). Is it normal for that wall to be very hot? I noticed the wall was very hot about two weeks before the hot water went out. It is hot all the time, there is no cool down period noted.
No need to get too involved, there's no way I could do this myself. I'm sure I need to call a plumber, I just don't want to get ripped off because I am ignorant.
Helpful
ballengerb1's Avatar
ballengerb1 Posts: 25,641, Reputation: 11296
Home Repair & Remodeling Expert
 
#6

Jan 14, 2008, 12:03 PM


Nytzsi, if you hear roaring all the time and the exhaust is too hot to touch all the time I think you should shut down the gas supply. Something is very wrong if it never stops firing and this could become a safety issue. If you call a plumber try the yellow pages for your area and call a licensed plumber. Like any industry there may be a crook or two out there but most plumbers value their reputation and word of mouth referrals.
Helpful
Nytzsi's Avatar
Nytzsi Posts: 7, Reputation: 1
New Member
 
#7

Jan 14, 2008, 12:18 PM
Thank you for your help. I called the manufacturer and they had me turn off the cold water supply to see if the burner turns off once it heats the water that's already in the tank. I'm supposed to call back with the answer in about 30 minutes.
The whole thing freaks me out, my grandfather was actually killed by a hot water heater bursting.
Anyway... To clear up what sounded like me bashing your business... I live in las vegas - everyone is a crook in las vegas. I have a half-finished hard wood floor from a contractor I hired at a home show that never finished. I also have some very screwed up stamped concrete stairs in front of my house that were created by someone that was referred to me by a trusted friend that's a contractor.
By the way... Anyone know any good contractors of any type in Las Vegas?
Helpful
ballengerb1's Avatar
ballengerb1 Posts: 25,641, Reputation: 11296
Home Repair & Remodeling Expert
 
#8

Jan 14, 2008, 12:24 PM
I am sure I am not smarter than the manufacturer but I would not shut off that supply line and allow the heater to continue to operate. That water will expand, if the heater is actually heating, and if you do not have an expansion tank it will eventually blow oopen the PRV on the side of the tank. Did that roar sound stop when you shut off the gas supply? It should have if the sounds was the main burner flame. I better understand your situation in LV, I'd be leary too after what you have ben exposed to.
Helpful  (1)
KISS's Avatar
KISS Posts: 12,602, Reputation: 4378
Uber Member
 
#9

Jan 14, 2008, 12:48 PM
I don't like the sounds of this. Draining a little water from the bottom of the tank would be enough to determine whether or not the water is hot.

When you turn off the cold water supply there is no place for the colder water to expand to so your depending on the temperature and pressure relief valve to function. In general when the supply is turned off, you should open a hot water faucet even though nothing will come out.

The broken dip tube seems very plausable and it has to have a cause. Some causes are:
1) Not draining sediment from the tank monthly.
2) Not using Dialectric unions if there is galvanized to copper fittings near the tank.
3) The water requires a water softener so that sediment is not likely to preform
4) The sacrificial anode rod has been sacrificed. They are replaceable too.
Helpful
Nytzsi's Avatar
Nytzsi Posts: 7, Reputation: 1
New Member
 
#10

Jan 14, 2008, 02:01 PM
The tank eventually stopped firing when water heated up with no new cold being introduced. When I turned the cold input back on then hot water worked in the house, we'll see if it lasts past 50 gallons. My guess is no.
The GE Hot Water Heater Hotline was a complete bust. When completing their test I called back and they guy had no idea what I was talking about. When I asked to be transferred to the gal that was previously helping me he got fairly rude. He put me on hold for a long time, and then told me I needed to test the temperature with some thermometer I'm supposed to have handy. Well, I don't have one handy and he thought that was pretty ridiculous. I just told him I'd call back after I go buy one. I won't be calling back. If the water runs cold after 50 gallons I'll call a real plumber. Thanks guys for all your help.
Helpful

Not your question? Ask your question View similar questions

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search

Add your answer here.

Remove Text Formatting

Undo
Redo
 
Decrease Size
Increase Size
Bold
Italic
Underline
Align Left
Align Center
Align Right
Ordered List
Unordered List
Decrease Indent
Increase Indent
Insert Email Link
Wrap [QUOTE] tags around selected text
Wrap [CODE] tags around selected text
Wrap [HTML] tags around selected text
Wrap [PHP] tags around selected text
Wrap [YOUTUBE] tags around selected text
Notification Type:



Check out some similar questions!

Radiators hot but hot water from taps luke warm [ 1 Answers ]

Hi, First of all I am novice..a real novice when it comes to plumbing, so please be easy on me :) I hope someone can shed some light on this weird problem. I have a conventional boiler with a hot water tank in the bathroom and 2 tanks in the loft. The radiators in the house are fine, they...

Luke warm water coming from 1 shower. [ 2 Answers ]

I'm having a problem with my hot water in my master bathroom shower. All Other showers and fausets have no problem. The master shower, seems to only give us luke warm water. The fauset is a single lever type which should mix the hot and cold to our liking. But what is happening when you try to...

Luke warm water from shower [ 3 Answers ]

Over the last few months I have noticed that my shower is not producing hot water the way that it used to. The sink tap gives out hot water, just not the shower anymore. I have noticed that when I flush the toilet there is an added burst of pressure from the shower. Do you have any idea what this...

Luke warm water from hot water tap [ 1 Answers ]

I purchased a condo (efficiency) that was converted from a motel. I 've had and have problems with hot water in taps. The unit is old and the feed pipes from the hot/cold water supplies are not accessible. Last year all I got was luke warm water from the shower and two taps in the unit. I had a...


View more Plumbing questions Search