    timmy0310's Avatar
    timmy0310 Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 13, 2008, 03:11 PM
    Luke warm shower
    New house all faucets and tubs are hot. Shower will only go to 1 temperature. Luke warm
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    Oct 13, 2008, 03:45 PM

    Brand new house or new to you? The shower mixing valve may have debris or solder caught in the hot intake. If the home is brand new the builder should cover the repair or we can walk you through it.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #3

    Oct 13, 2008, 05:07 PM
    Hey Timmy...

    If newer home then may or may not be that code has recently required that shower and tub/shower valves be reduced to 112 degrees F as maximum temperature and the rest of the fixtures maintained at about 120 degrees F max...

    What is the name on your valve?

    There will probably be a temperature LIMITING adjustment that can be adjusted to a greater temperature... AS LONG AS THERE ARE NO CHILDREN IN THE HOME... :)

    If children present then I highly recommend that you keep that shower and all tub/shower valves limited to 112-115 degrees F maximum as required by all plumbing codes that I know of... for the safety of all!

    If no kids then let us know the name on shower valve and we will see if we can direct you to the limiting screw... jump that temp. up to 125 or so... ;)

    MARK
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #4

    Oct 13, 2008, 05:39 PM
    [QUOTE=timmy0310;1319451]New house all faucets and tubs are hot. Shower will only go to 1 temperature. Luke warm[/QUOTe



    Are you saying that you can not get even cold water at the shower. Only luke warm no matter where you turn your faucet? If so, I would say you have a bad cartridge. If you can get cold water only, but the hottest water you can get is luke warm, then you should be able to adjust the anti-scald setting in your faucet.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Luke warm air [ 3 Answers ]

I also have a GMP100-3 furnace and the air has always been just luke warm. Maybe that is why my gas bills are 300 to 400 a month. The gas pressure you are talking about is the incoming or out of the gas valve? What is the easest way to check it myself?

Luke warm radiators [ 1 Answers ]

About three years ago we had a new Buderus boiler installed. I don't think we are getting the best heat from it through our cast iron radiators we have a two story home with 10 radiators of varying size between both floors. It takes about 45-50 minutes for the temp in the house to raise 2 degrees....

Luke warm water coming from 1 shower. [ 2 Answers ]

I'm having a problem with my hot water in my master bathroom shower. All Other showers and fausets have no problem. The master shower, seems to only give us luke warm water. The fauset is a single lever type which should mix the hot and cold to our liking. But what is happening when you try to...

Luke warm water from shower [ 3 Answers ]

Over the last few months I have noticed that my shower is not producing hot water the way that it used to. The sink tap gives out hot water, just not the shower anymore. I have noticed that when I flush the toilet there is an added burst of pressure from the shower. Do you have any idea what this...


View more questions Search