| | | low water pressure whole house Help!
I have a 20 year old home and have noticed problems with the pressure in the last two months or so. I thought that it was mostly a hot water problem, but noticed today that my upstairs toilet wouldn't flush completely or refill. It seems to be getting worse each day. Initially, we thought it might be that we're just using too much hot water and simply running out...but I suspect it's bigger than that.
I've read some of the similar postings and answers from labman and speedball1. I tried shutting off the cold water inlet to the hot water heater; opening the highest and furthest hot water tap; and opening the drain valve to see if that would free up any blockage. When I do this, do I completely run out the water heater or just do it for a short while?
Any help would be wonderful.  | | | | | | |
Answers
 | |  | | |
Oct 28, 2006, 06:15 PM
|
#2
| | Senior Member
Join Date: Oct 2006 Location: Alabama
Posts: 834
| You mention two different issues or did I misunderstand ? 1) You do not have enough hot water for normal household use 2) You have very little wate pressure, ie your toilet didnt flush - are you also experiencing very little water pressure in all outlets in your home ? |
| | | | | | |  | |  | | |
Oct 28, 2006, 06:34 PM
|
#3
| | New Member
Join Date: Oct 2006
Posts: 4
| THANKS FOR THE QUICK RESPONSE! You're right. There may be two issues going on. Initially it was just the hot water problem, ie. not enough for normal household use. Then today I noticed the toilet flushing problem. Could they be tied together? |
| | | | | | |  | |  | | |
Oct 28, 2006, 06:35 PM
|
#4
| | New Member
Join Date: Oct 2006
Posts: 4
| I forgot something...yes, it is in all the outlets in the home. |
| | | | | | |  | |  | | |
Oct 28, 2006, 07:07 PM
|
#5
| | Senior Member
Join Date: Oct 2006 Location: Alabama
Posts: 834
| I dont think the two problems are tied together. Here's what I would do, Monday moring call you the utility company, city that supplies your water, tell them about your experiences with lack of sufficient water pressure. They might respond by simply telling you that they are flusing the system in your area or that they are working on a water main. If you can, ask you neighbors if they are having the same lack of sufficent water prressure.
As to the lack of an adequate amount of hot water, look at either your make and model number of your water heater on the heater itself or on your owner's manual if you have one to determine if you have one or two heating elements - my guess is that you only have one and the one remaining working element is not heating your water fast enough to supply your needs - OR you have a defective thermostat that is not regulating the temp of your water properly. Thermostats usually are far less often defective than heating elements as they not are exposed constantly to hot and cold water and temperature extremes like heating elements.
I dont think you told us how old the unit was or if heating elements had ever been replaced. Most people dont think to check them, I dont, I just worry about them when I have a problem like you are having now, so my best guess is that they have never been replaced or looked at. They are not that hard to replace, cost only about $15.00 each, take maybe 2 hours to replace if you are a "novice plumber". A profess plumber can probably replace two elements in about 30 minutes.
Let us know if you have one or two elements, how old the heater is and if you know if the elements have ever been replaced. |
| | | | | | |  | |  | | |
Oct 29, 2006, 05:01 AM
|
#6
| | | Senior Plumbing Expert
Join Date: Jan 2003 Location: Sarasota, Fl.
Posts: 14,473
Pay to call speedball1 for advice ($.95/min) | Hi Casey,
Yes, you have two separate problems. Lets address them one at a time.
Your hot water problem sounds like the bottom element in the heater is faulty and needs to be replaced, ( sorry Richard but one element heaters went outa style in the 50's).
"I've read some of the similar postings and answers from labman and speedball1. I tried shutting off the cold water inlet to the hot water heater; opening the highest and furthest hot water tap; and opening the drain valve to see if that would free up any blockage. When I do this, do I completely run out the water heater or just do it for a short while?"
WRONG!! You don't shut the cold water off and you don't drain the tank.
For long life and fewer troubles you should keep your heater clear of mineral build-up by flushing on a regular schedule. let me show you how. Attach a hose to the boiler drain at the bottom of the tank. With the pressure on, open the boiler drain and let it run untill the water runs clear. You will see a spurt of red,(rust) followed by white grains,(lime or calcium carbonate). This shouldn't take more then a few minutes. Do this monthly to keep it clear. Now flush out your hot water lines on ALL fixtures. Now pull each aerator and clean the screens. Be sure you put them back togather the same way you took them out. Don't forget to flush it out every month. Your heater will thank you for it.
Now, on to your pressure concerns. Is the entire house affected or just the toilet? How old is your house and what material are the pipes? Copper? Galvanized? Please explain with more details. Regards, Tom |
| | | | | | |  | |  | | |
Oct 29, 2006, 05:55 AM
|
#7
| | Senior Member
Join Date: Oct 2006 Location: Alabama
Posts: 834
| Please forgive me, go with Speedball's answer, he's the pro, not me, thanks Speedball for correcting me, sure thought they still made and sold one element heaters.
Here's where you corrected me on the one/two element issue:
Yes, you have two separate problems. Lets address them one at a time.
Your hot water problem sounds like the bottom element in the heater is faulty and needs to be replaced, ( sorry Richard but one element heaters went outa style in the 50's). |
| | | | | | |  | |  | | |
Oct 29, 2006, 07:24 AM
|
#8
| | New Member
Join Date: Oct 2006
Posts: 4
| Thanks Tom.
Please let me clarify a couple of things. Every morning things are fine with the water pressure in the whole home, with the "normal" exception that the water pressure drops for someone in the shower when someone else flushes a toilet elsewhere in the house. Then at night, after the days activities of loads of laundry, running the dishwasher and giving the kids a bath, the hot water pressure is low. When I run the kids bath, it is a little more than a trickle. So I don't have a problem with the amount of hot water, just the amount of hot water pressure. The cold water pressure is fine. This is true in the whole house, not just one or two fixtures.
In answer to your questions: House was built in 1987 and has copper pipes throughout. It's a 40 gallon gas hot water heater.
About the toilet. This was a newer issue and only happened once about two days ago. The upstairs toilet would not refill after flushing. I think that might have been due to the downstairs toilet running longer than usual because the flapper didn't seat properly. Once I discovered that, it seemed to take care of the upstairs toilet problem.
So any help on the whole house hot water pressure problem would be very much appreciated.
Casey |
| | | | | | |  | |  | | |
Oct 31, 2006, 03:34 PM
|
#9
| | New Member
Join Date: Oct 2006
Posts: 6
| replace it |
| | | | | | |  | |  | | |
Oct 31, 2006, 04:23 PM
|
#10
| | | Senior Plumbing Expert
Join Date: Jan 2003 Location: Sarasota, Fl.
Posts: 14,473
Pay to call speedball1 for advice ($.95/min) | Do you flush out the mineral build up in your heater on a regular maintenance schedule? Mineral buildup can get into your pipes and clog the system. Let me repeat my advice.
I've read some of the similar postings and answers from labman and speedball1. I tried shutting off the cold water inlet to the hot water heater; opening the highest and furthest hot water tap; and opening the drain valve to see if that would free up any blockage. When I do this, do I completely run out the water heater or just do it for a short while?"
WRONG!! You don't shut the cold water off and you don't drain the tank.
For long life and fewer troubles you should keep your heater clear of mineral build-up by flushing on a regular schedule. let me show you how. Attach a hose to the boiler drain at the bottom of the tank. With the pressure on, open the boiler drain and let it run untill the water runs clear. You will see a spurt of red,(rust) followed by white grains,(lime or calcium carbonate). This shouldn't take more then a few minutes. Do this monthly to keep it clear. Now flush out your hot water lines on ALL fixtures. Now pull each aerator and clean the screens. Be sure you put them back togather the same way you took them out. Don't forget to flush it out every month. Your heater will thank you for it. Let me know if it helped. We may have to flush out your hotwater pipes if flushing the heater didn't work. Regards, Tom |