Question
 
 
#1  
Old Aug 23, 2008, 10:58 AM
Baseman219
New Member
Baseman219 is offline
 
Join Date: Aug 2008
Posts: 2
Baseman219 See this member's comment history on his/her Profile page.
Loss of water pressure w/new pressure tank

Hello everyone,
I have a question involving my plumbing. I was having terrible water pressure and I checked the pressure at the pump itself and it was great. Went to the pressure tank and it was trickling. shut down power to pump and drained system - checked air pressure and it was not registering. Tried to refill tank and it would not hold pressure. Decided to replace tank (old one was 20 gal) and since i am using an awful lot of water (dishwasher/washing machine/family of 5 - so 2 to 3 showers a day, etc.,etc.) i wanted to go with a larger tank (86 gal). Installed with no problem (moderate experience.) and left the factory pre-charge at 30 psi. Opened all faucets, turn on water pump, waited for all air to be released and closed faucets. waited 1 hr. to let tank fill. and now i can not get any more than 15 to 17 psi (according to gauge near tank). and when i shut power down and try to drain system, i am only getting about 2 to 5 gal from the system only. please help

baseman219

Reply With Quote
 
     

Answers
 
 
Old Aug 23, 2008, 01:01 PM   #2  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 14,473
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Something doesn't sound right here.
Quote:
Opened all faucets, turn on water pump, waited for all air to be released and closed faucets. waited 1 hr. to let tank fill. and now i can not get any more than 15 to 17 psi (according to gauge near tank). and when i shut power down and try to drain system, i am only getting about 2 to 5 gal from the system only.
You waited for a bladder tank to fill? You have just mixed a bladder tank with a pressure tank and that's not how it goes. Bladder tanks don't "fill". They expand internally with pressure.
I need to knoew the cut in pressure of your control box. Your bladder tank has to be charged according to the cut in point on the control box. Let me know what the control box reads on the case and I'll walk you through charging your bladder tank. Regards, Tom
  Reply With Quote
 
     
 
 
Old Aug 23, 2008, 08:12 PM   #3  
Senior Member
jlisenbe is offline
 
Join Date: Dec 2005
Posts: 538
jlisenbe See this member's comment history on his/her Profile page.
I'm a little confused as to how you had pressure at the pump (must be above ground?) and no pressure at the tank. How did you measure the pressure at the pump? Does it have a gauge above the pump housing? Some do, but I'm just interested in how you did this.

I suspect your pump is the problem. There is no way I know of you can have pressure at the pump and no pressure in the tank unless you have some peculiar blockage between the pump and the pressure tank, or perhaps a blocked/defective check valve between the tank and pump. Even if you do not have the pressure at the top of the tank set correctly, that would not prevent the tank from filling sufficiently to get up to cutoff pressure, certainly not after an hour.

Just to be clear, and I am certain SB simply phrased this hurriedly, the bladder tank itself does not expand. The bladder in the tank does so.

Comments on this post
albinfla agrees: Good advice...a blockage is what I suspect too
  Reply With Quote
 
     
 
 
Old Aug 24, 2008, 09:45 AM   #4  
Full Member
albinfla is offline
 
Join Date: Jul 2008
Location: Tampa, FL
Posts: 311
albinfla See this member's comment history on his/her Profile page.
If you'll please give us the make/model # of your pump, we can offer more exact advice. I think that you may have pressure internally on the pump, which is why your gauge is registering. I'm just guessing without knowing the type of pump. But, that is probably just the internal back-pressure of water supplying the jet of the pump.

jlisenbe had good advice to check for a blockage. Either a gate valve has a gate stuck closed. If the handle just spins, and never stops when you're opening it, it is a sure sign of a "dropped gate". Also, you could have a check valve jammed closed.
Al
  Reply With Quote
 
     
 
 
Old Aug 30, 2008, 04:42 PM   #5  
New Member
Baseman219 is offline
 
Join Date: Aug 2008
Posts: 2
Baseman219 See this member's comment history on his/her Profile page.
sorry about not getting back with you all. I had my neighbor come over and we found out that in the pump was submersible, and that the top of the pump - where the pipe is threaded in - was broken off. pump was fine but the pressure was not being pushed up pipe (found out that it was 100 ft. down). we replaced the pump and made sure that all connections were heat shrink wrapped to ensure no water causing damage - also installed a torque suppressor to eliminate this from happening again in the near future. Again thank you for your suggestions - sorry I didn't get back with you until now.
  Reply With Quote
 
     
 
 
Old Aug 31, 2008, 06:22 AM   #6  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 14,473
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Great Baseman,
Thanks for filling us in. Good luck and if we can ever be of service in the future just click on back. Good luck, Tom
  Reply With Quote
 
     


Thread Tools
Display Modes

 
Similar Sponsors

Similar Threads
Question Asker Forum Answers Last Post
Water pressure against tank height and tank water capacity shoaibdr Physics 3 Apr 12, 2008 10:30 PM
No water in pressure tank Marci777 Plumbing 10 Mar 24, 2008 04:04 PM
new hot water tank installed, loss of water pressure LeaSmith31 Plumbing 1 Jun 11, 2007 01:30 PM
water well pressure tank fay11961 Plumbing 2 Mar 23, 2007 05:31 AM
water pressure tank brianeedshelp Plumbing 1 Jan 16, 2007 03:06 PM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 01:32 AM.