    Installing new shower in basement, no drain
    We are going to put a corner shower stall in our basement bathroom which currently only has a sink and a toilet. There is no drain where we want to put the shower. Do we have to break up the concrete and put a drain in the floor and then run pipes over to the toilet or sink drain, or is there any way we can build up the shower 6 or 8 inches and then run the pipes along the floor to the drain? Thanks.
    darrel1953's Avatar
    darrel1953 Posts: 86, Reputation: 12
    Junior Member
     
    #2

    May 31, 2005, 08:18 PM
    Yes you can, but
    Yes you can, but it probably won't be legal. You can see how the drain comes out of the wall to hold the trap and go up to the drain of the sink. The horizontal pipe is called the dirty arm. You can run that 5 feet and the horizontal vent will still do it's job, however if you add another dirty arm that is considered wet venting and in most places it is prohibited unless the vent part of the pipe is oversized. Wet venting can create problems like siphoning that will leave traps dry and allow sewer gases into the house. The other problem with that is that the drain for a shower is to be 2 inches not 1-1/2 like a sink line can be. So it really matters what size the pipe is in the ground and to the roof. Ask your local authority if they would allow you to do what you want coming off the vertical line venting the toilet. They may have an answer for you but you will need to know the sizing of all of your pipes in question including where you want them to go and where they terminate.
    Darrel
    Flickit's Avatar
    Flickit Posts: 278, Reputation: 2
    Full Member
     
    #3

    Jun 1, 2005, 06:12 AM
    You claim the drain...
    Quote Originally Posted by darrel1953
    Yes you can, but it probably won't be legal. You can see how the drain comes out of the wall to hold the trap and go up to the drain of the sink. The horizontal pipe is called the dirty arm. You can run that 5 feet and the horizontal vent will still do it's job, however if you add another dirty arm that is considered wet venting and in most places it is prohibited unless the vent part of the pipe is oversized. Wet venting can create problems like siphoning that will leave traps dry and allow sewer gases into the house. The other problem with that is that the drain for a shower is to be 2 inches not 1-1/2 like a sink line can be. So it really matters what size the pipe is in the ground and to the roof. Ask your local authority if they would allow you to do what you want coming off of the vertical line venting the toilet. They may have an answer for you but you will need to know the sizing of all of your pipes in question including where you want them to go and where they terminate.
    Darrel
    ... from a shower/tub should be 2 inches but why are they nearly always supplied with a 1 1/2" drain? Makes it a pain to find an adapter.
    pinantan33's Avatar
    pinantan33 Posts: 2, Reputation: 1
    New Member
     
    #4

    Jun 1, 2005, 10:41 AM
    Thank you very much for your reply. I have been searching all over the net for instructions on how to do this and I couldn't find anything. I really appreciate the information.
    joseph719's Avatar
    joseph719 Posts: 1, Reputation: 1
    New Member
     
    #5

    Feb 14, 2011, 11:42 AM
    Quote Originally Posted by pinantan33 View Post
    We are going to put a corner shower stall in our basement bathroom which currently only has a sink and a toilet. There is no drain where we want to put the shower. Do we have to break up the concrete and put a drain in the floor and then run pipes over to the toilet or sink drain, or is there any way we can build up the shower 6 or 8 inches and then run the pipes along the floor to the drain? Thanks.

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Installing drain for shower in basement [ 1 Answers ]

My questions has three parts. The purpose of this is that I want to install a shower in the basement. Background: I recently bought a 90 year old home. The basement has recently been redone (new concrete floor and completely dry--thank god). It already has a toilet installed, resting directly on...

Installing a shower trap in the basement [ 2 Answers ]

Hello, This is my first post. When I purchase my house a full bath was roughed into the basement. I am in the process of installing a shower base in my basement. The builder roughed in the shower as follows - 6 inch PVC pipe straight into the concete

Installing shower in unfinished basement [ 1 Answers ]

I'm beginning a project to add a basement bathroom in our house. The house is only two years old and the basement is unfinished with concrete slab. The builder roughed in a drain for the toilet, sink and also the shower. My question is about the shower drain. Currently it is a 2" pvc pipe...

Installing a shower base in the basement [ 17 Answers ]

We bought a home that already had a sewage pump installed in the basement with three drains already installed in the concrete floor that leads to this pump's tank. One was for a toilet (which is covered), another is for a sink (which at present is in use) and the third is a drain pipe (rubber...

Installing a basement shower(?) [ 2 Answers ]

We bought a home that already had a sewage pump installed in the basement with three drains already installed in the concrete floor that leads to this pump's tank. One was for a toilet (which is covered), another is for a sink (which at present is in use) and the third is a drain pipe (rubber...


View more questions Search