    If my foot valve is bad would my pump hold pressure at all?
    Its winter and I'm having issues keeping water pressure in my system. Sometimes I can get it but as soon as the pump kicks on the pressure fluctuates dramatically and then goes to 0 and stays there. I then close the valve between the pump and pressure tank so I can prime the pump. When I check the lines they are full of water including the pump itself. So I have prime right? If the pump is running and isolated from the pressure tank it normally will built pressure fast then shut off, loose pressure and come back on doing this continues. I think this is normal because its not going to the pressure tank. When I open the valve to the tank rather than building pressure slowly it will fluctuate and 9 times out of 10 it will go to 0 after a while. However at this moment it built pressure.

    So my question is, If the foot valve is bad would it build pressure at all? Or would it sometimes build and sometimes not? Can a pump act this way? Any way to test the pump?

    It's a deep well with a jet pump. 2 lines going into the well. There is a lot of iron in our water and there is an orange film in the lines. I have a T in each line at the pump with a plug so I can prime easily. I did this because it happens a lot in the summer and filling at the top of the tank is a pain. When I pull the plugs out I can see the water is right to the top, same with the pump. Frustrating as hell.

    I'm going to experiment tonight. The system is pressurized at the moment. I will close the valve between the pump and pressure tank for the night and see if it looses pressure. I see no movement in the pressure gauge of a short time but perhaps over night it will drop. This should indicate if I have a leak or a bad foot valve right? I'm about 1 day away from buing a new pump just to rule it out.

    Help please. Mike
    AncientGames's Avatar
    AncientGames Posts: 2, Reputation: 1
    New Member
     
    #2

    Feb 19, 2011, 07:48 AM
    Checked the pump this morning and the PSI has drop 12. So, I either have a leak or a bad foot valve correct?
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #3

    Feb 19, 2011, 08:06 AM

    With the valve you referred to off, the pump should pump up QUICKLY to cut off pressure, then shut off and hold that pressure. What you are describing points to a leaking footvalve or a leaking pipe. Your pump should also hold prime month after month without needing repriming.

    BTW, jet pumps generally have a plug at the top of the impeller cage (might be a pressure gauge) which is used to prime the pump.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Water pump pressure builds too high and trips the pressure valve [ 1 Answers ]

First I had to replace the breaker for the water pump because the breaker must have went bad because I had no power to the pump. Fixed that and everything worked fine. I had to shutoff the water supply to repair a leak in a pipe. After I repaired the pipe I turned the water back on and got no water...

Pump is short cycling and blowing foot valve off. [ 1 Answers ]

I woke up Saturday to no water; checked the pump into house and it was running (did not notice the short cyle at the time) so shut it off and checked holding tank. There was plenty of water but the pvc pipe that has the foot valve screwed into it was off. So let the pump cool down and put pipe...

How do you know when a foot valve needs replacing on ruthberry well pump? [ 0 Answers ]

My hot water tank went out my son in law replaced itr and he hooked the hot water to the cold and cold to hot on top of the tank then he lit it and said I should have hot water in about an hour . In about an hour I had no water at all and my pump had lost it's Prime and we put about 10 gallons of...

Could my foot valve cause my well pump to lose it's prime [ 1 Answers ]

My water keeps cutting off. Could it be a faulty foot valve. I added air to my tank and also put a new switch on the pump.

I can't get my jet pump to prime and my foot valve is working correctly [ 1 Answers ]

5 days ago my hubby was drilling holes for a garage and hit our water line he repaired the break in the feed and return line, we tried to prime the pump and we cannot get the pressure to build like it should. We have checked to repairs to make sure they are not leaking... nothing 5 days later we...


View more questions Search