How to prevent a banging noise from the sewage ejector pump

Asked May 14, 2010, 04:01 AM — 5 Answers
About every 15-30 minutes our ejector pump goes off and just after it flushes we hear a large banging noise. It's so annoying. What can we do to prevent this banging sound? The pump is located in our unfinished basement. There isn't a bathroom down there or anything. There is 1 check valve and I can hear the water trickling into the pump. Please help.

5 Answers
CHayn's Avatar
CHayn Posts: 177, Reputation: 45
Junior Member
 
#2

May 14, 2010, 04:10 AM
1. Where is the trickling water coming from? Leaking toilet? Dripping faucet? Find out and repair.
2. Make sure your pipe coming from the pump is not against any ductwork, other pipes, or floor joists. Put some insulation between these items if it is that way but make sure there is no contact with ductwork or the banging will be awful.
3. Install another check valve closer to the highest elevation of the discharge pipe so there is not as much water pressure slamming the check valve shut.
4. They do make quiet close check valves but they close slower allowing more waste water to backflow back into your pit.
Helpful
jcaultman's Avatar
jcaultman Posts: 2, Reputation: 10
New Member
 
#3

May 14, 2010, 06:25 AM
All of the bathrooms, shower, laundry, etc pipes flow down into the basement. There is nothing leaking or anything, just assumed that it's normal part of the waste being ejected out. I will check out the duct work because my husband did rough out the basement so we could finish it. Is there a limit to how high the 2nd check valve should be from the 1st check valve? There is also a knob on the check valve to turn off and on is this normal? Do you have suggestions on how to change a check valve and is there a particular kind to buy?
Helpful
CHayn's Avatar
CHayn Posts: 177, Reputation: 45
Junior Member
 
#4

May 15, 2010, 05:48 AM
I think you should really investigate where the water is coming from that is causing your ejector pump to run so often. The plumbing from the upper levels should not be going into the sewage ejector pit. Only basement level fixtures typically go into a pit. Basement bathrooms, floor drains, etc. Something is dumping water in there to make it run so often. Ground water should not go into a sewage ejector pit.
Okay, yes the knob over the check valve is normal. They also make check valves that are just the check with fernco type (rubber) couplers on either end. That is what I would suggest for this application of putting one higher. Leave the one in that is already there also. Make sure you purchase a 2" check. As far as elevation is concerned you could put it about 12 or 18" below its highest point.
This is only to soften the blow on the check valves. It will not completely take the noise away but it will make it more quiet. If you want it to be as quiet as possible get a quiet close valve. They are spring loaded so the flapper doesn't slam shut with the backpressure. However, they do allow more waste to flow back into your pit and your pump will cycle more often.
Be aware that when you cut the pipe above the check valve there is waste water in this pipe! I would open the lower check by taking it apart below the check and use a long screwdriver to push the flapper open from the bottom so you can direct this waste into your pit or a bucket.
By the way, the knob over the check. That is only there to service the check valve. Do Not close this knob with the pump plugged in.
Helpful
daveprice74's Avatar
daveprice74 Posts: 1, Reputation: 1
New Member
 
#5

May 3, 2012, 04:18 PM
Do Not close this knob with the pump plugged in.

Haha I almost did that.

"Maybe it's to close the check valve," I thought. "I'll just close it a little and see what happens."

The banging noise can be fixed with another check valve, placed vertically at the top of the vertical piping. That will keep the water from falling back dwn.
Helpful
speedball1's Avatar
speedball1 Posts: 25,069, Reputation: 8939
Senior Plumbing Expert
 
#6

May 4, 2012, 06:20 AM


Quote:
Originally Posted by daveprice74 View Post
Do Not close this knob with the pump plugged in.

Haha I almost did that.

"Maybe it's to close the check valve," I thought. "I'll just close it a little and see what happens."

The banging noise can be fixed with another check valve, placed vertically at the top of the vertical piping. That will keep the water from falling back dwn.
Hi Newest and Welcome to The Plumou one of your ownbing Page. at AskMeHelpDesk.com. You're responding to a 2 year old dead thread.. Look in then upper left hand corner of the first post form the date in the first post before you post, Thanks, Tom
Helpful

Not your question? Ask your question View similar questions

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search

Add your answer here.

Remove Text Formatting

Undo
Redo
 
Decrease Size
Increase Size
Bold
Italic
Underline
Align Left
Align Center
Align Right
Ordered List
Unordered List
Decrease Indent
Increase Indent
Insert Email Link
Wrap [QUOTE] tags around selected text
Wrap [CODE] tags around selected text
Wrap [HTML] tags around selected text
Wrap [PHP] tags around selected text
Wrap [YOUTUBE] tags around selected text
Notification Type:



Check out some similar questions!

Sewage ejector pump making a very loud banging noise after it shuts off. [ 2 Answers ]

In my basement I have a sewage pit for my bathroom/kichen. After the ejector pump shuts off it makes a very loud bang that can be heard throughout the whole house. The discharge pipe is 2" and is approximately 7' from the top of the pit to the ceiling where it makes a 90 degree to the main...

Is Meyers pentair sewage ejector pump model SR1830 a quality pump? [ 1 Answers ]

Just installed a sewage ejector pump and I'm somewhat concerned about the manufacture. Not seeing very much information about Meyer. I see Zoeller and Little Giant, so I'm wondering if I got a quality systems. Considering all that was required to get the system in I don't want to revisit this for...

Sewage ejector pump [ 2 Answers ]

My basement sewage pump just stopped working? I checked the ele.breaker it is fine. The pump was just installed about 3 mo. Ago, and was new? What could be the problem? Thanks

Sewage ejector system noise and joint separation [ 10 Answers ]

I have a problem with my basement sewage ejector system that has puzzled the first pluber and contractor I've brought in for help. The problem ultimately presents itself with a very violent water hammer sound when the pump shuts off, and along with that the pipe and rubber joint above the check...

Sewage ejector pump [ 2 Answers ]

I had a home built over 2 years ago. We have a full finished basement with a bathroom and a laundry room. The builders installed an ejector pump to get the waste up to the street sewage line, and we have had problem after problem with it. 3 times over the past 2 years, the pump has been...


View more Plumbing questions Search