Ask Experts Questions for FREE Help!
Ask    ||    Answer
 
Advanced  
 

Ask QuestionsprogressAnswer QuestionsprogressBuild ReputationprogressBecome an Expert
 
Free Answers in 3 Easy Steps

Register Now
3 Steps

At Ask Me Help Desk you can ask questions in any topic and have them answered for free by our experts. To ask questions or participate in answering them you must register for a free account. By registering you will be able to:
  • Get free answers from experts in any of our 300+ topics.
  • Accept money for answers that you provide.
  • Communicate privately with other members (PM).
  • See fewer ads.

Home > Home & Garden > Plumbing   »   How to find gas leak

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Jul 21, 2009, 10:59 AM
antipode12
Full Member
antipode12 is offline
 
Join Date: Jul 2007
Location: Long Island, NY
Posts: 237
antipode12 See this member's comment history on his/her Profile page.
How to find gas leak

My fiancee smelled a slight gas smell the other day so we called the gas co. Their test found nothing, but I asked to have the line shut down anyway.

Called in a plumber yesterday who pressurized the system and found it dropped from 4 psi to about 3 in 15 minutes.

Went through all of the exposed piping with the soapy mix, and found a few very small leaks in the threading. He removed, resealed, and retightened each one.

Still had a pressure drop.

He had to leave, but we still have 2 joints left to test (they are enclosed in the wall -- I will expose them this afternoon).

Assuming that those two joints do not solve the problem, what should the next step be? How do I find a leak elsewhere? Or could the "repaired" joints still be unrepaired?

Thanks.

Reply With Quote
 
     

Answers
 
 
Old Jul 21, 2009, 11:56 AM   #2  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,977
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Here's how you can check it yourself. there's a device you can make yourself. You failed to mention the pipe size so I'm going to assume it's 3/4". You take a 3/4"(or your pipe size) coupling and bush it down to accept a snifter valve. A snifter valve looks like the air valve on your tire except it has threads at the base. Snifter valves can be picked up at some hardware stores and most auto parts stores. Since most air compressures the plug into a cars cigarette lighter have a gauge I would pump up the gas line with that or a bicycle pump with a gage.
OK! Ya got 10 pounds of air in the gas line what now? We check for leaks by taking a mixture of water and dish detergent and painting each joint with it. If you see bubbles then you have a leak. No bubbles and you're home free. good luck, Tom
  Reply With Quote
 
     
 
 
Old Jul 21, 2009, 01:38 PM   #3  
Engineering & Electronics Expert
KeepItSimpleStupid is offline
 
KeepItSimpleStupid's Avatar
 
Join Date: Aug 2007
Posts: 9,315
KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.
Hey Speedball:

Your new Avatar could use some Crack Spackle. Found some right here:

Long Sleeve Longtail T Crack Spackle - Duluth Trading Company

You just jealous because I have a "cute Tush"!!
  Reply With Quote
 
     
 
 
Old Jul 21, 2009, 08:01 PM   #4  
Full Member
antipode12 is offline
 
Join Date: Jul 2007
Location: Long Island, NY
Posts: 237
antipode12 See this member's comment history on his/her Profile page.
Thanks Speedball, but that's not the problem.

My plumber has the compressor and gauge for the test. (And the bubbles!)

The problem is that have tested 10 joints so far (finding 3 very small leaks) and only have 3 elbow joints left. I am afraid that we will finish and the pressure on the test will still drop.

Is there anywhere else to look for a leak? Do we re-check the joints all over again?

I just want something to suggest when the plumber looks at me and shrugs.

(I'm having a lot of trouble with the techs around here. Seems nobody is thorough or well-equipped. I find myself leading *them* around by the nose.)
  Reply With Quote
 
     
 
 
Old Jul 21, 2009, 08:19 PM   #5  
Engineering & Electronics Expert
KeepItSimpleStupid is offline
 
KeepItSimpleStupid's Avatar
 
Join Date: Aug 2007
Posts: 9,315
KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.
See http://www.askmehelpdesk.com/plumbin...in-142944.html

Electronic detection should be better.

Standing pilots on old ranges don't shut off, so there a source of leaks that are not leaks.
  Reply With Quote
 
     
 
 
Old Jul 22, 2009, 05:33 AM   #6  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,977
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Antipode, What type of joints are you testing? Copper and compression or black iron and threaded joints. As a rule once the gas line's pressured up the plumber won't leave in the middle of the test without testing all the joints. What makes your job different? Regards, Tom
  Reply With Quote
 
     
 
 
Old Jul 22, 2009, 02:06 PM   #7  
Full Member
antipode12 is offline
 
Join Date: Jul 2007
Location: Long Island, NY
Posts: 237
antipode12 See this member's comment history on his/her Profile page.
Quote:
Originally Posted by speedball1 View Post
Antipode, What type of joints are you testing? Copper and compression or black iron and threaded joints. As a rule once the gas line's pressured up the plumber won't leave in the middle of the test without testing all the joints. What makes your job different? Regards, Tom
Black pipe and threaded joints.

The plumber got there at 6pm and stayed through 9. His partner took over this morning. I got hosed. Huge.

What happened was he pressurized the line, sprayed the bubbles, and kept finding the most miniscule leaks. Barely noticeable. Like, I couldn't really see them. They seemed like just the natural popping of tiny bubbles. No big leaks, no big bubbles anywhere. (He did not have the same electronic sniffer the gas company had. He pressurized the line to 4 pounds; the meter says maximum of 5.)

So he unthreaded, cleaned, and re-sealed each joint that he saw a leak on -- 4 or so. But his gauge kept dropping pressure to 3 pounds.

This morning, his partner continues with the remaining 4 joints; same story. Finally with one particularly obstructed T-joint left, he decided to try a new gauge, thinking his original one was broken.

Viola! No pressure drop.

So I said "does that mean the other joints were fine?" He says "no" because teh soap still showed leaks.

This whole experience has me furious. (Not to mention that the original gas company test did NOT show a leak reading, but because we -- not him -- smelled a slight odor, he locked the gas line until a plumber came out.)
  Reply With Quote
 
     
 
 
Old Jul 22, 2009, 02:38 PM   #8  
Junior Member
pelle is offline
 
Join Date: Sep 2006
Posts: 87
pelle See this member's comment history on his/her Profile page.
If the gas meter is on try this .. shut off all appliances at the appliances shut so no pilots are on and nothing con come on. Go to your gas meter there should be a dial called test dial pick the smallest dial ie. 1/2, 1 or 2 foot dial. probably a half on a residential house put a pen mark where the dial is a move away from the gas meter for a while quite a while. The go back and see if there is any movement or rotation. if so go to every joint with soap and water. also any flex lines like for a range or dryer soap them up with your hand bend them and move them a little bit sometimes they get small cracks if they are old.
  Reply With Quote
 
     
 
 
Old Jul 23, 2009, 03:53 AM   #9  
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 5,438
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
Pelle...thanks, but Antipode is all set here as they have indicated that the gauge was broken and the new gauge showed no leaks...

MARK
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
Can't find leak in Gas Pipes
(7 replies)
have roof leak cant find leak
(1 replies)
How to find leak
(4 replies)
Cannot Find Water Leak
(3 replies)
cant seem to find leak from tub
(7 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 12:54 PM.