Ask Me Help Desk

Ask Me Help Desk (https://www.askmehelpdesk.com/forum.php)
-   Plumbing (https://www.askmehelpdesk.com/forumdisplay.php?f=259)
-   -   How do you replace the Symmons temprol diverter (https://www.askmehelpdesk.com/showthread.php?t=354816)

  • May 17, 2009, 10:08 AM
    akchenderson
    How do you replace the Symmons temprol diverter
    How do you replace the temprol diverter in a Symmons single valve shower/tub assembly?
  • May 17, 2009, 04:04 PM
    massplumber2008
    Hi Akchenderson:

    Remove all of the chrome trim parts and then you will need a 5/16" allen wrench to remove the DIVERTER RETAINER and a 5/16" x 3" LAG BOLT to remove the DIVERTER SPINDLE itself. Although the bolt sounds wrong it is exactly what Symmons recommends.

    You will need to screw the 5/16" lag bolt into the spindle and then give a strong YANK to remove the old spindle (hold valve body here). To install the new spindle you will need to grease (silicone grease) the new spindle at the O-RING to insert it into the valve body... push hard to seat it. Then re-install the retainer (be careful not to drop it... ;)) and test all.

    That should get you up and running again...

    MARK