    How do you remove the broken closet flange from a cast iron drain pipe?
    I have a broken cast iron pipe and want to remove the broken section to replace it but it is sealed with something, lead I think. I am worried that doing so might break the good pipe. How can this be done with out damaging the good pipe?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Jul 24, 2012, 09:42 AM
    Quote Originally Posted by Mowhaw View Post
    I have a broken cast iron pipe and want to remove the broken section to replace it but it is sealed with something, lead I think. I am worried that doing so might break the good pipe. How can this be done with out damaging the good pipe?
    You have a lead and oakum caulked joint that first must be remogved.

    To remove a poured lead and oakum joint take a 3/8" drill bit and drill a few holes down past the lead and into the oakum.. Push a screwdriver under the lead ring and lever it up. Once it's free you can began to peel the lead ring out. Now pick out the oakum and you can pull the joint apart. You may now pull the flange up and out. Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Offset Closet Flange for Cast Iron? [ 6 Answers ]

Hi, My cast iron waste pipe centerline is 11 inches from the finished wall. It worked with my old toilet (since disposed of) but won't work for my new Kohler. Is there an offset for cast iron that is easy to install? BTW, the floor was tiled and the old closet flange had an extra flange as a...

How can I remove a Brass/Copper fitting on a cast iron drain pipe [ 1 Answers ]

After removing a copper drain pipe there is a fitting on the cast iron drain pipe where the copper pipe was sweated to. I can see threads and I heated it with a torch but it is very stubborn and does not want to move. How can I remove this more heat? Or should I look for a copper connector with...

How do I seal pvc toilet flange to cast iron drain pipe [ 1 Answers ]

Just bought a house with damaged toilet. Existing plumbing is pvc toilet flange inserted into cast iron drain line. The flange is loose and needs to be refastened to the floor, subfloor condition permitting . How do I seal the pvc toilet flange to cast iron drain pipe to ensure no sewer gas leak?

Raise closet flange on cast iron pipe [ 3 Answers ]

I am installing a new hardwood floor in my bathroom and a new wc. The waste line is cast iron. What is the simplest way to raise the flange the 3/4" (I think) to accommodate the new floor? Thanks Steve

Can you connect a cast iron closet flange to an ABS Pipe? [ 9 Answers ]

I have to move my toilet over an inch from the wall per inspector's request. I have searched the internet and have not found an ABS offset closet flange that would work for me. I did however find a cast iron flange that measures 4" x 2" (Jones Stephens Corp. Model # C44-420). Is it at all...


View more questions Search