Question
 
 
#1  
Old Sep 7, 2008, 01:31 PM
Ghanouni
New Member
Ghanouni is offline
 
Join Date: Sep 2008
Posts: 1
Ghanouni See this member's comment history on his/her Profile page.
How to change a PRV?

My PRESSURE CONTROL VALVE on my home water line no longer controls the water pressure and the pressure is up to 150PSI when measured. It appears that the PCR is shot. I discovered that because the water heater started leaking through pressure relief valve. I chanaged the PRV twice and the leaks continues.... I understand that I need to install an expansion tank and intend to do it. Please answer the following two questions:
1- Is the PCR bad?
2- Is it easy to replace it? I have copper pluming. Thanks

Reply With Quote
 
     

Answers
 
 
Old Sep 7, 2008, 03:23 PM   #2  
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 5,476
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
The temperature and pressure relief valve should indeed have blown off as it is designed to blow off at 210F or 150 PSI..so good that valve is doing its job.

With that in mind, certainly sounds like the pressure regulator is shot...

Most pressure regulators have a union on one side. If this is case with your regulator then you should only need to shut the water main off at the water meter, open some faucets in the house and then release the union fitting by using two wrenches or pliers and then simply remove the pressure regulator by loosening valve counterclockwise. Then apply teflon tape 6-7 wraps clockwise and install a new pressure regulator, etc...

If your pressure regulator doesn't have a union then you will need to shut the water off to the house as above and you will need to cut into the copper tubing say 6 inches PAST the pressure regulator (i.e., on the reduced pressure side) and then remove the old regulator using two wrenches as above and reinstall new one using teflon tape, etc., again as posted above. Then you will need a SHARKBITE type copper tubing coupling (see picture below)...this will simply push onto one side of the copper tubing and then you will push the other end of the copper tubing deep into the fitting and you will be finished installing the unit(available at all home supply stores today). Using this fitting will keep you from having to solder any pipes!

Then you want close any faucets you opened, then open the water meter shutoff, and then open the nearest laundry faucet or outside faucet to purge any sediment/air from the system that was disturbed via working on the main line. Then you will open all faucets and fiunish purging air from lines.

Finally, you need to take a reading on the pressure and see what pressure the regulator is set too...anywhere between 45 and 60 psi is acceptable range. Anything above or below will require you to make adjustments to the knob on top of unit to finish this job.

Always a good idea to have an expansion tank...come back when time to install this and we'll be glad to walk you through.

Let us know if you have any questions...

MARK
Attached Images
 
  Reply With Quote
 
     
 
 
Old Sep 7, 2008, 05:50 PM   #3  
Ultra Member
afaroo is offline
 
Join Date: Aug 2007
Location: California
Posts: 1,881
afaroo See this member's comment history on his/her Profile page.
I would like the following just for info as mark says you need to check the pressure you would need a water pressure gauge see the images below, good luck.

John
Attached Images
  
  Reply With Quote
 
     
 
 
Old Sep 7, 2008, 06:01 PM   #4  
Home Repair & Remodeling Expert
ballengerb1 is offline
 
ballengerb1's Avatar
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 15,449
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
Got losts of terms here, PRV and PCR. You are talking about a pressure reducing valve (PRV) but you say you replaced it twice?? I'm confused. Did you replace it twice or adjust it twice?
  Reply With Quote
 
     
 
 
Old Sep 7, 2008, 07:08 PM   #5  
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 5,476
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
Here's how I read it Bob...

Ghanouni wants to change his PRV (pressure relief valve) because the pressure control valve is shot. He appears to have changed the PRV twice and I can't be 100% sure but he seems to be calling the pressure control valve a PCR... Of course, to complicate things it's actually a pressure regulator (PR) or a pressure reducing valve (PRV) as posted by John...which really complicates things because there is just too many PTMMGHT (Ps that make me go hmmm, too)!!

I will only barely mention the fact that you added to fun here by calling a pressure relief valve a PRT...and ghanouni never even mentioned a PRT...

Let us know what's up Ghanouni...


MARK
  Reply With Quote
 
     
 
 
Old Sep 7, 2008, 09:29 PM   #6  
Engineering & Electronics Expert
KeepItSimpleStupid is online now
 
KeepItSimpleStupid's Avatar
 
Join Date: Aug 2007
Posts: 9,351
KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.
The thingy on the water heater will leak if the thingy (1) on the water main is broken or adjusted improperly. The thingy (2) on the water heater may or may not have to be replaced even if it leaked.

An expansion tank should only be necessary if someone installed yet another thingy (Check valve, backflow preventer) on the main.

It should all be clear once the technical terms are defined.

1. Something that regulates pressure and is usually adjustable
2. A pressure and temperature relief valve. Failures are USUALLY non-destructive.
  Reply With Quote
 
     
 
 
Old Sep 8, 2008, 07:44 AM   #7  
Home Repair & Remodeling Expert
ballengerb1 is offline
 
ballengerb1's Avatar
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 15,449
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
Mark, if I'm going to quote a guy I guess I should do it right, made the correction. I don't think we will get anywhere until Ghanouni returns to straighten this out but I think he is confusing the names and functions of the PRV and the P&T.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes
Ask your question or search...



Similar Threads
would the NPV change if the cost of capital change and why?
(1 replies)
Minor Name Change/Birth Certificate Change
(2 replies)
Name change
(1 replies)