    Hot water runs out after 5-10 minutes
    Hi,

    Need some assistance: I have a 30 gallon gas hot water heater about 10 yrs old with copper plumbing and after taking the shower for 5-10 minutes, there is no more hot water.

    What are some of the possible causes & fix?

    Thank you,
    Matt
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Feb 23, 2006, 03:07 PM
    Quote Originally Posted by askme1
    Hi,

    Need some assistance: I have a 30 gallon gas hot water heater about 10 yrs old with copper plumbing and after taking the shower for 5-10 minutes, there is no more hot water.

    What are some of the possible causes & fix?

    Thank you,
    Matt
    Hi Matt,
    And 5 or 10 minutes are down from a normal shower of ? This could be caused by a dip tube that fell off, mineral buildup on the floor of the tank or a low thermostat setting. Have you considered changing your shower head for a "water saver" one? Cheers, tom
    askme1's Avatar
    askme1 Posts: 7, Reputation: 1
    New Member
     
    #3

    Feb 27, 2006, 03:09 PM
    Tom,

    The next person would have to wait 30 minutes later to take a shower after the initial 5 or 10 minutes. What is a dip tube? The thermostat is set at almost to the end of "hot" so I would assume it is hot enough? Would some maintanance improve the capacity and what would you recommend? Also, Is the age of the water heater a potential cause?
    Thanks a lot for you help!!

    Matt
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Feb 27, 2006, 03:26 PM
    Hey Matt,
    Your 10 year old heater most likely has mineral build up on the floor of the tank that's acting as a insulator. This would give you the slow recovery that your complaining about. If you had a bad dip tube your hot water would run out right away. My guess is that your heater has to be flushed clear of what's built up down there. For long life and fewer troubles you should keep your heater clear of mineral build-up by flushing on a regular schedule. Let me show you how. Attach a hose to the boiler drain at the bottom of the tank. With the pressure on, open the boiler drain and let it run until the water runs clear. You will see a spurt of red,(rust) followed by white grains,(lime or calcium carbonate). This shouldn't take more then a few minutes. Do this monthly to keep it clear. If you have 10 years of build up you may have to drain the heater and pour a can of C L R into it and let it set over night and then flush it out again. Your only other option would be to replace the heater since the average lifre of a water heater's 8 to 10 years. Good luck. Tom
    Don't forget to flush it out every month. Your heater will thank you for it
    askme1's Avatar
    askme1 Posts: 7, Reputation: 1
    New Member
     
    #5

    Mar 6, 2006, 10:39 AM
    Tom,

    What's the best way to pour the CLR into the tank without unsoldering the pipes?

    Many thanks for all your help,
    Matt
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #6

    Mar 6, 2006, 01:53 PM
    Quote Originally Posted by askme1
    Tom,

    What's the best way to pour the CLR into the tank without unsoldering the pipes?

    Many thanks for all your help,
    Matt
    Hi Matt,
    Drain the heater and remove the T & P valve,( Temperature. Pressure Relief) qnd pour it in there. Let it work overnight and next morning flush the heater out. Regards, tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search


Check out some similar questions!

Inside fan runs, outside fan runs, but air is not cold [ 8 Answers ]

The inside fan runs and runs, the outside fan on the compressor runs and runs, but only hot air comes out. I sprayed the outside compressor coils with the garden hose to clean them and checked the inside filter. Is there something else I could check? Thanks

Water pools around furnace when a/c runs [ 1 Answers ]

A couple of times this summer I have noticed a pool of water around my furnace while my air conditioner is on. I have a central air conditioner and the air is distributed through my house via the furnace blower and conduits. Today, I had some time to poke around a bit and it seems that the pool is...

Page cannot be displayed after 3 minutes [ 2 Answers ]

Win 98se , 256mb, sys rec @ 85% free, cable , router, IE 6.0 version 6.0.2800.1106 When online, after about 5 minutes my browser seems to die. Im still online, outlook will come up and send email successfully, and if I'm playing a game, I can play all night, as long as I don't close it...

Disconnection after 15 minutes [ 2 Answers ]

Hay; From few days I have a disconnection problem I did'nt understand what is the problem in my system let me known the symptoms of a modem failur. I have d815 mother board with 1.2 ghz intel processor And a 56k support modem please answere me.


View more questions Search