Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Jan 31, 2007, 12:12 PM
brokenpipes
New Member
brokenpipes is offline
 
Join Date: Jan 2007
Posts: 3
brokenpipes See this member's comment history on his/her Profile page.
hot water pipe touching fire sprinker pipe

I discovered why the water pressure in my fire prinkler system kept rising. It's because the hot water pipe is right up against the sprinkler pipe causing it to heat which then increases the pressure. Now can I wrap the pipe with insulation. Would this be a good fix? If so, should I wrap the hot water pipe or the sprinkler pipe to keep it cool? The house is 13 yrs old. Have the pipes started to sink down or what?

Reply With Quote
 
     

Answers
 
 
Old Jan 31, 2007, 01:28 PM   #2  
letmetellu
Ultra Member
letmetellu is offline
 
Join Date: Dec 2005
Location: Texas
Posts: 1,753
letmetellu See this member's comment history on his/her Profile page.letmetellu See this member's comment history on his/her Profile page.
If you have room put a piece of insulation on each one of the pipes. And yes the house may have settled a little over the years.
  Reply With Quote
 
     
 
 
Old Jan 31, 2007, 01:53 PM   #3  
speedball1
Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 12,671
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Go down to your local plumbing shop and pick up some Armo-Flex Insulation. Insulate both pipes. Good luck, tom
  Reply With Quote
 
     
 
 
Old Jun 3, 2007, 09:41 PM   #4  
soundman
New Member
soundman is offline
 
Join Date: Jun 2007
Posts: 3
soundman See this member's comment history on his/her Profile page.
If it's a single hot water pipe touching the sprinkler pipe, I don't really think that's your problem. There's not enough heat transfer there to change your water pressure in your sprinkler system. What I think you're seeing is a surge from the city water system. Happens all the time. BTW, I install fire sprinkler systems.
  Reply With Quote
 
     
 
 
Old Jun 4, 2007, 08:50 AM   #5  
speedball1
Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 12,671
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
If soundman's correct then a PRV(pressure regulator valve) would solve the problem. Good luck, Tom
  Reply With Quote
 
     
 
 
Old Jul 15, 2007, 06:15 PM   #6  
Turbopro25
New Member
Turbopro25 is offline
 
Join Date: Jul 2007
Location: Brick, NJ
Posts: 16
Turbopro25 See this member's comment history on his/her Profile page.
I install Fire Sprinkler Systems for a living as well and agree. That would not be enough to cause the rise. Typically the rise would be from extreme changes in air temperature or a boost from the city pressure over night. Typically surges will happen over night and push more pressure into the system. You probably have a backflow, or check valve on the system that keeps the pressure in. I test all my sprinkler systems at 210 lbs pressure for all my inspections, so the pipes are capable of holding that type of pressure. Is there a drain valve you can crack open slowly to drain the pressure? If so do that before you go to sleep if the pressure is back up high in the morning it may be surges. Do this again in the morning and check later in the afternoon.
  Reply With Quote
 
     
 
 
Old Jul 15, 2007, 06:17 PM   #7  
Turbopro25
New Member
Turbopro25 is offline
 
Join Date: Jul 2007
Location: Brick, NJ
Posts: 16
Turbopro25 See this member's comment history on his/her Profile page.
By the way if you have alarms wired to the system do not open or close any valves without notifying the alarm companies and local authorities. You don't want to set off a flow switch or Tamper alarm. You may want to insulate those to pipes touching anyway, so the copper does rot away.
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Hot water pipe blockage rattyvulcan Plumbing 10 Jan 26, 2007 01:19 AM
No Hot water to one pipe and rattling/squealing pandy Plumbing 4 Nov 5, 2006 02:12 PM
natural gas pipe in bsmt is touching gas pipe brent Heating & Air Conditioning 2 Aug 11, 2006 06:02 PM
blocked central heating hot water pipe shark Heating & Air Conditioning 2 Mar 30, 2005 09:55 AM
How to plan gas pipe job to hook-up tankless hot water heaters MIademarco Plumbing 7 Jan 6, 2005 05:27 AM