Question
 
 
#1  
Old Dec 27, 2007, 01:21 PM
Socrbob
New Member
Socrbob is offline
 
Join Date: Dec 2007
Posts: 2
Socrbob See this member's comment history on his/her Profile page.
hot water heater valve

What do you think is wrong with a relief valve that does not leak when the electric is turned off, but leaks when the electric is turned back on and mild(100 degrees or so) hot water comes from the faucets.

Reply With Quote
 
     

Answers
 
 
Old Dec 27, 2007, 01:29 PM   #2  
Home Repair & Remodeling Expert
ballengerb1 is online now
 
ballengerb1's Avatar
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 15,446
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
Replace it. When you shut off the power your water begins to slowly contract so there is a slight drop in pressure. When the power is on the water heats and expands, with all faucets closed, the pressure builds up a bit. Your PRV is right at the point of failing and should be replaced.

Comments on this post
Socrbob agrees: You are correct, when I replaced the valve it was stuck open with a chunk of buildup. Thank you.
  Reply With Quote
 
     
 
 
Old Dec 27, 2007, 02:33 PM   #3  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,992
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
If you have a sprinkler system with a backflow preventer installed next to the meter you MUST have a expansion tank installed on the cold water inlet to the heater. Do you have such a set up without a expansion tank? If so all the new T&P valves in the world won't stop the leak. Regards, Tom

Comments on this post
Socrbob agrees: If you take out the part about the sprinkler system which was not mentioned in the question the answer is correct. The value needed to be replaced. Thank you.
  Reply With Quote
 
     
 
 
Old Dec 27, 2007, 06:04 PM   #4  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
Tom is right. You may not even need a new PRV. It is just doing its job. Unfortunately, often once they open, they get crud on the seat and always leak then.

Comments on this post
Socrbob agrees: You are correct, when I replaced the valve it was stuck open with a chunk of buildup. I will remember not to open it to flush it as the tag suggests.Thank you.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
surging water pressure & leaking water heater relief valve
(13 replies)
Pressure relief valve / water heater