#1  
Old Aug 5, 2009, 02:04 PM
jimbo902
New Member
jimbo902 is offline
 
Join Date: Aug 2009
Posts: 4
jimbo902 See this member's comment history on his/her Profile page.
hot water in cold tap

I added a shower to my place and now I got hot water coming out of my cold taps for the first 15 seconds or so. All I changed from before was to add 2 tees into the line, one from the hot and one from the cold water lines. What's happening? thx.

Reply With Quote
 
     

Answers
 
 
Old Aug 5, 2009, 03:58 PM   #2  
Ultra Member
mygirlsdad77 is offline
 
Join Date: Aug 2008
Posts: 2,663
mygirlsdad77 See this member's comment history on his/her Profile page.mygirlsdad77 See this member's comment history on his/her Profile page.
do you have a hot water recirc pump on your system? If you do, make sure you didnt tie into the recirc line instead of the hot water feed line. Also, how close to the water heater are the tees you installed?
  Reply With Quote
 
     
 
 
Old Aug 6, 2009, 10:31 AM   #3  
New Member
jimbo902 is offline
 
Join Date: Aug 2009
Posts: 4
jimbo902 See this member's comment history on his/her Profile page.
I have no pump and the tees are about a foot and a half from the hot water tank.
  Reply With Quote
 
     
 
 
Old Aug 6, 2009, 06:45 PM   #4  
Heating and Air Conditioning Expert
letmetellu is online now
 
Join Date: Dec 2005
Location: Texas
Posts: 2,847
letmetellu See this member's comment history on his/her Profile page.letmetellu See this member's comment history on his/her Profile page.letmetellu See this member's comment history on his/her Profile page.
This might explain your problem. When the water in the water heater is not used for a while the heated water in the tank will expand and go backwards into the cold line, also the law of phisics applies here that hot rises and cold falls, therefore again you have hot water rising into the hot water line. Since your tee's are so close to the water heater some of the hot is backed up in the cold line that furnishes your new tee and until the hot is flushed out you will get the small amount of hot water out of the cold line.

If you have some one to help you check this you check the heat in the cold water inlet at the heater and see if it is real warm and when someone turns on the cold in the shower it gets cool.

Comments on this post
ballengerb1 agrees: I can go with this too
mygirlsdad77 agrees: yep, i agree too. Sounds like this is exactly what is happening.
Milo Dolezal agrees: Good answer...!
  Reply With Quote
 
     
 
 
Old Aug 7, 2009, 03:22 PM   #5  
Ultra Member
mygirlsdad77 is offline
 
Join Date: Aug 2008
Posts: 2,663
mygirlsdad77 See this member's comment history on his/her Profile page.mygirlsdad77 See this member's comment history on his/her Profile page.
If this is the case, nothing to worry about really. If you just cant stand it. you can install a either a heat trap, or a heat trap nipple off the top of the cold inlet side of water heater. If you do go the heat trap route, make sure that the trap is between the water heater and any other colds that come off the cold water heater supply
Attached Images
  
  Reply With Quote
 
     
 
 
Old Aug 7, 2009, 07:19 PM   #6  
New Member
jimbo902 is offline
 
Join Date: Aug 2009
Posts: 4
jimbo902 See this member's comment history on his/her Profile page.
I installed a check valve at the hot water heater and that fixed the problem totally. Thx to everyone for their info.
  Reply With Quote
 
     
 
 
Old Aug 7, 2009, 07:23 PM   #7  
Ultra Member
Milo Dolezal is offline
 
Milo Dolezal's Avatar
 
Join Date: Jun 2008
Location: So. California
Posts: 3,735
Milo Dolezal See this member's comment history on his/her Profile page.Milo Dolezal See this member's comment history on his/her Profile page.Milo Dolezal See this member's comment history on his/her Profile page.
Quote:
Originally Posted by jimbo902 View Post
I installed a check valve at thhe hot water heater and that fixed the problem totally. Thx to everyone for their info.
Congratulations...Milo
  Reply With Quote
 
     
 
 
Old Aug 7, 2009, 07:29 PM   #8  
Heating and Air Conditioning Expert
letmetellu is online now
 
Join Date: Dec 2005
Location: Texas
Posts: 2,847
letmetellu See this member's comment history on his/her Profile page.letmetellu See this member's comment history on his/her Profile page.letmetellu See this member's comment history on his/her Profile page.
Quote:
Originally Posted by jimbo902 View Post
I installed a check valve at the hot water heater and that fixed the problem totally. Thx to everyone for their info.
Putting a check valve in the incoming line to a water heater is not a good idea. The reason being that in a case where the gas to the burner fails to cut off you do not have a one hundered percent safty that steam will not build up in your heater and create a bomb.

And yes I know that you have a pop-off valve for such emergencies, and you have a cut off build into the thermostat to protect against this sort of problem. But none of them are one hundred percent postive protection.
  Reply With Quote
 
     
 
 
Old Aug 8, 2009, 07:24 AM   #9  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,992
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
I can see LetmetellU s point about the check on the cold water supply but if there's already a backflow preventer install the system's closed already. I didn't think of that in my reply. Thinking it over I think you're absolutely correct Lee.
A check valve and expansion tank it is. Cheers, Tom
Attached Images
 
  Reply With Quote
 
     
 
 
Old Aug 9, 2009, 02:43 PM   #10  
Ultra Member
mygirlsdad77 is offline
 
Join Date: Aug 2008
Posts: 2,663
mygirlsdad77 See this member's comment history on his/her Profile page.mygirlsdad77 See this member's comment history on his/her Profile page.
I think you will be just fine with the check valve, but you will need to add an exansion tank on the water heater side of check valve. Many areas require a check valve on home incoming water anyways, so installing one on the cold supply of water heater makes no difference.(except to cure your problem of hot water in cold line) The reason for the expansion tank is so that when the water in the water heater heats up and expands, it wont blow off your temp/ pressure relief valve. I personally would have like to see you use the heat trap nipples, but a check valve will work just fine to.. Just make sure to get that expansion tank install asap. With a check valve installed right before water heater, it wouldnt hurt to manually pop off your pressure relief vavle now and again just to make sure it is not stuck. 'The only problem with this is,,, once you pop them off manually, they tend to drip, so i would have a spare one on hand just in case you cant get it to shut down completely.

Tom, just wondering how an expansion tank will take the place of a check valve. I dont think an expansion tank will keep the heat from radiating up the cold side. But i have been wrong before, and i promise i will be wrong again(most likely many times..)
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
bathroom water pressure vey poor from cold water storage tank
(1 replies)
New hot water heater installed, but no hot water pressure. Plenty of cold water?
(8 replies)
Hot water only - no cold water - soft water system
(4 replies)
Cold water coming out of hot water tap in bathroom but Really hot water in kitchen
(6 replies)
Brand new water heater: Starts off hot, then water gets cold after few seconds
(1 replies)

Search this Thread