Home > Home & Garden > Plumbing   »   hesitation about Fernco Neoprene Coupling hidden in wall...

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Aug 29, 2005, 04:10 AM
atticguy
Junior Member
atticguy is offline
 
Join Date: Aug 2005
Location: milwaukee, wisconsin
Posts: 36
atticguy See this member's comment history on his/her Profile page.
hesitation about Fernco Neoprene Coupling hidden in wall...

hello again, (you guys rock)

i am converting my cast stack to pvc and am concerned about the transition point. i was hoping to use a PVC NO-Hub band 'donut' at the a particular cast hub but it doesn't look like that's possible. my question is:

are those couplings reliable enough to install inside of a wall and just forget about it?

please keep in mind that i will be discharging a half bath past the transition. i understand that i should leave as small a gap as possble (with nice clean straight cuts) between the cast and pvc within the band and then tighten to a particular torque, to minimize complications. but i'm just so darn nervous about not having access to this joint. am i being unreasonably anal?...

thanks again,

louie

Reply With Quote
 
     

Answers
 
 
Old Aug 29, 2005, 06:15 AM   #2  
Über Member
RickJ is offline
 
RickJ's Avatar
 
Join Date: Aug 2005
Location: The Bogs at Windover
Posts: 7,363
RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.
I've got literally dozens of Fernco's No Hubs buried in walls...some many many years old.

I've never had a problem with any of them.

Heck, the No-Hubs are more reliable than the old cast
  Reply With Quote
 
     
 
 
Old Aug 29, 2005, 06:57 AM   #3  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,992
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by atticguy
hello again, (you guys rock)

i am converting my cast stack to pvc and am concerned about the transition point. i was hoping to use a PVC NO-Hub band 'donut' at the a particular cast hub but it doesn't look like that's possible. my question is:

are those couplings reliable enough to install inside of a wall and just forget about it?

please keep in mind that i will be discharging a half bath past the transition. i understand that i should leave as small a gap as possble (with nice clean straight cuts) between the cast and pvc within the band and then tighten to a particular torque, to minimize complications. but i'm just so darn nervous about not having access to this joint. am i being unreasonably anal?...
thanks again,
louie
Hey Louie,

You are correct to be concerned using a Fernco Neoprene Coupling on a vertical stack unless the two pipes butt together and are strapped securely.
However since you can't use a Fernco Coupling on a cast iron hub,( you must have two male ends to couple to) it's a moot question. You have only two choices to convert to PVC from a cast iron hub. One is to pour a lead and oakum joint and the other is to use a "doughnut". If it's impossible to use a doughnut, (and I don't see why not) and if you're leery about pouring a lead joint it's possible to use lead wool and caulk that in place of molted lead.
Let me know what you decide. Tom
  Reply With Quote
 
     
 
 
Old Aug 29, 2005, 07:38 AM   #4  
Junior Member
atticguy is offline
 
Join Date: Aug 2005
Location: milwaukee, wisconsin
Posts: 36
atticguy See this member's comment history on his/her Profile page.
"i was hoping to use a PVC NO-Hub band 'donut' at the a particular cast hub but it doesn't look like that's possible"

i should have said, "i was hoping to use a 'donut' at the next particular cast hub but it doesn't look like that's likely, it isn't possible (ie cost/time effective) to get at the next hub. there is a LOT of stuff/utilities in the way. i will be cutting the cast iron. therefor, i will only have 2 male ends. the cast and the pvc"

my question still remains the same however,

are those couplings reliable enough to install inside of a wall and just forget about it?

sorry about the mix-up.
  Reply With Quote
 
     
 
 
Old Aug 29, 2005, 07:51 AM   #5  
Über Member
RickJ is offline
 
RickJ's Avatar
 
Join Date: Aug 2005
Location: The Bogs at Windover
Posts: 7,363
RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.
For applications where I've been able to find the right one - and have plenty of room to get it on right - we've never had a problem with it afterwards.
  Reply With Quote
 
     
 
 
Old Aug 29, 2005, 09:21 AM   #6  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,992
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by atticguy
"i was hoping to use a PVC NO-Hub band 'donut' at the a particular cast hub but it doesn't look like that's possible"

i should have said, "i was hoping to use a 'donut' at the next particular cast hub but it doesn't look like that's likely, it isn't possible (ie cost/time effective) to get at the next hub. there is a LOT of stuff/utilities in the way. i will be cutting the cast iron. therefor, i will only have 2 male ends. the cast and the pvc"

my question still remains the same however,

are those couplings reliable enough to install inside of a wall and just forget about it?

sorry about the mix-up.
If I had a choice I would go for a cast iron to PVC NO-Hub Band Coupling since it's much more ridgid then a Fernco Neoprene coupling. But a Fernco's acceptable if the pipes butt together and you strap both pipes securely so they can't move. Rick's right. If the Fernco is installed correctly you should have no problems since neoprene won't deteriorate over the years.
Good luck, Tom
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
How do I install the motor coupling for my washer?
(0 replies)
hidden programs in xp
(1 replies)
Hidden electric showers
(1 replies)
Pontiac grand am 98 se 2.4 engine hesitation
(7 replies)
Fernco under slab - sround with Concrete?
(1 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 07:03 PM.