    Fixed Pipe but still no water
    We had a leaky pipe from our water main.

    We turned off the water fixed the pipe and let it sit over night to make sure it was set. We turned the water back on at the main this morning be we aren't getting any water back in the house. What happened? What can we check? Should we have had something in the "on" position when we turned the water back on? The Pipe is PVC.. The Small leak was shortly after the water main. We dug down to the pipe.. Cut out the broken part and glued in new pipe. We can get a small trickle of water.. but that's it and eventually it will run dry. I have tried turn off the main.. opening all the faucets and slowling trying to turn the water back on at the main but it doesn't seem to make a difference. I have turned it back off at the main since it would appear there is pressure building there (I assume that is a pressure gauage on the water meter)..
    queens's Avatar
    queens Posts: 6, Reputation: 1
    New Member
     
    #2

    Dec 14, 2007, 05:34 AM
    Hi, first check the place that you have fixed, most of the pipe leakage is from the joint, I'm afrait you have wrongly installed the fitting, or else, your house piping system has air locked. Try to release air from the pipe line.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Dec 14, 2007, 06:43 AM
    Forget the air lock. That's not the problem. If you had air in your lines all you would have to do is open a faucet and bleed it off. We are talking about the water service from the meter4 aren't we? Exactly where was the leak that you repaired? What fitting was leaking and how did you repair it? What material are the pipe and was it in a trench when you worked on it? In short, we need more details. Regards, Tom
    mesaaz's Avatar
    mesaaz Posts: 2, Reputation: 1
    New Member
     
    #4

    Dec 14, 2007, 09:17 AM
    The Pipe is PVC.. The Small leak was shortly after the water main. We dug down to the pipe.. Cut out the broken part and glued in new pipe. We can get a small trickle of water.. but that's it and eventually it will run dry. I have tried turn off the main.. opening all the faucets and slowling trying to turn the water back on at the main but it doesn't seem to make a difference. I have turned it back off at the main since it would appear there is pressure building there (I assume that is a pressure gauage on the water meter)..
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #5

    Dec 14, 2007, 10:49 AM
    Not like Tom to ask for the details you already gave. He may be the best member we have. Maybe the suggestion of an air lock distracted him.

    I would break the line again even if you have to saw it in two. Couplings are cheap. Crack the valve and see if you get any water. If not, cautiously open the valve look at the valve. Remove the pipe to get a good look at it if you need to. If all you can see or feel is a solid metal disk, you may have a crappy old gate valve that the stem has come loose from the gate. That requires help from the city. If the valve is open, and you see crud on the other side, you could poke it with a screwdriver being ready to close the valve quickly.

    You didn't give any clue where you are. Unless you are in Sunny Florida with Tom, what a fun time to be doing plumbing outside. My pump recently got some debris in the check valve. I was able to clean it out, and it is working fine now. It would have been a much easier job if the pump wasn't at the lower end of 40' of pipe. Of course, that is starting 3' under the ground. The whole time I had the well open, I had to bail to keep to the surface water from getting into the well.

    Next time, could I just install a check valve between my pressure tank and where the pipe goes out the foundation? It is warm and dry in my crawl space and more room than in the hole I dug down to the well.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Teflon or Pipe Dope for 1 1/4" Water Pipe [ 7 Answers ]

I am building a project that uses several joints of 1 1/4 " galvanized pipe, including elbows and Tee's. The unit will be plumbed into my 50 psi water system. What is the best way to seal the pipe joints? I have assembled the unit and tested using teflon pipe dope and had several leaks.

Trickling or No Water in Cold Water Pipe in 1 Bathroom [ 1 Answers ]

The cold water in the sink and toilet tank in our basement bathroom comes out either as a trickle or not at all. The cold water works fine in all the other bathrooms (2), the kitchen and laundry room. The toilet water connection is turned on all the way, as is the sink. The hot water in the sink...

Hot water pipe touching fire sprinker pipe [ 6 Answers ]

I discovered why the water pressure in my fire prinkler system kept rising. It's because the hot water pipe is right up against the sprinkler pipe causing it to heat which then increases the pressure. Now can I wrap the pipe with insulation. Would this be a good fix? If so, should I wrap the hot...

Fixed PB tubing/copper pipe union [ 1 Answers ]

Re Polybutylene tubing, threaded transition union. Thx speedball for your help. I have cut out 4" of the leaking union and replaced it with 2 5/8" compression unions attached to a 4" 1/2" copper pipe. The PB tubing also incorporated a copper insert with the compression fitting. I know you...


View more questions Search