Home > Home & Garden > Plumbing   »   Exterior Plumbing Vent, should there be a visible pipe?

 
Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Mar 7, 2008, 10:05 AM
suzieperfect
New Member
suzieperfect is offline
 
Join Date: Mar 2008
Posts: 1
suzieperfect See this member's comment history on his/her Profile page.
Exterior Plumbing Vent, should there be a visible pipe?

We recently had a half bath installed on the first floor of our home. For a variety of reasons, we asked that the vent be put through the exterior wall as opposed to going up through 3 floors and through a slate roof. My question: our contractor says that the vent is there, but all I see is a VERY small hole in the siding of our house that goes to the bathroom wall and presumably connects somehow to the plumbing. Should there be some sort of exterior pipe connecting through this small hole to the plumbing? Is this pipe supposed to run above our roof line?
We had many contractors come in for estimates and most of them cautioned us that an exterior plumbing vent would look ugly (I thought because it was going to run up the side of our house). We opted for it because it was far less expensive than the alternative of running it through 3 floors/slate roof, etc.
The contractor is demanding his final payment and I am very uncomfortable with this vent. THanks for any information!

Reply With Quote
 
     

Answers
 
 
Old Mar 7, 2008, 12:01 PM   #2  
speedball1
Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 13,188
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
My question: our contractor says that the vent is there, but all I see is a VERY small hole in the siding of our house that goes to the bathroom wall and presumably connects somehow to the plumbing.
Call the contractor back and have him finish the vent, Terminating a vent with a hole in the wall is a code violation. My Code, ( Standard Plumbing Code Chapter14, section 1404.4 and .5) will NOT allow him to terminate a outside building vent beneath any window, ventilating system or within 10 feet of any such opening. Once outside the house the vent shall be turned upwards and screened to prevent critters from entering. This vent should be approved by the plumbing inspector before installation. ( a little late for that isn't it?) Good luck and keep me informed. Tom

Comments on this post
suzieperfect agrees: Very helpful. Thank you, I will discuss with our contractor.
  Reply With Quote
 
     
 
 
Old Mar 7, 2008, 03:29 PM   #3  
Eric D
Junior Member
Eric D is offline
 
Join Date: Jan 2008
Location: Southern Michigan
Posts: 93
Eric D See this member's comment history on his/her Profile page.
While on the question of plumbing vents, are the units in this LINK legal?

Eric D
  Reply With Quote
 
     
 
 
Old Mar 7, 2008, 03:41 PM   #4  
massplumber2008
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 2,614
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
Hi Eric...checked the site....what UNITS are you talking about?
  Reply With Quote
 
     
 
 
Old Mar 7, 2008, 04:08 PM   #5  
Eric D
Junior Member
Eric D is offline
 
Join Date: Jan 2008
Location: Southern Michigan
Posts: 93
Eric D See this member's comment history on his/her Profile page.
Quote:
Originally Posted by massplumber2008
Hi Eric...checked the site....what UNITS are you talking about?

If you scroll down a little in the link you will see a photo of the vent. This type of vent is said to be allowed in an attic or inside a wall or even under a sink. There is also a pdf in the site with more details as well. I have seen these in the big box home stores as well. I was wondering if they would meet local codes in place of a through the roof or wall vent system.

This is from the Link in my first posting:

AAVs are accepted by major model building and plumbing codes, including IRC 2003, for single or multi family residential construction, and by American Society of Sanitation Engineers (ASSE). However, some local code authorities may be unfamiliar with Air Admittance Valves or reluctant to accept them despite code listing. Prior to using an AAV, an installer should contact the local building code official for specific approval status. In the United States, one open-air plumbing vent per structure is required.

Eric D
  Reply With Quote
 
     
 
 
Old Mar 8, 2008, 05:34 AM   #6  
speedball1
Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 13,188
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
In my area we have used AAV's in remodels, (never in new construction) they may only be installed if the plumbing inspector OK's it. The reason that this is on a case by case basie is that a AAV is a spring loaded mechanical device that is subject to fail over time. With a regular vent through the roof you do not have these concerns. It is also strongly recommended that if you install a AAV that it not be installed inside a wall and if it is a access service panel MUST be installed so it can be serviced or replaced. regards, Tom
  Reply With Quote
 
     
 
 
Old Jun 25, 2008, 04:48 PM   #7  
westnlas
Full Member
westnlas is offline
 
westnlas's Avatar
 
Join Date: Jun 2008
Posts: 322
westnlas See this member's comment history on his/her Profile page.
Evidently the contractor didn't obtain the permits for the work ? If permits are required for this work where you live, why was this allowed to proceed illegally ? Unfortunately, saving a few bucks on property taxes cost many thousands in resales. Most states have laws against a contractor doing un permitted work when one is required. I don't think you should pay him anything until this matter is resolved first. Just say that you will give him a cashier's check when he provides you with proof that the job has been done legally and passed inspection.

He may not be able to do this.

Before I retired, I made a lot of money tearing out patios, illegal room additions and modifications to return the properties to a legal status. Most lenders will not (or then anyway) loan on "as is" sales without thorough inspections. At that time everything needed to be brought to code.
  Reply With Quote
 
     
 
 
Old Jun 25, 2008, 08:36 PM   #8  
Milo Dolezal
Senior Member
Milo Dolezal is offline
 
Join Date: Jun 2008
Location: So. California
Posts: 708
Milo Dolezal See this member's comment history on his/her Profile page.
Every plumbing fixture has to be vented. Vent should terminate 12" above the roof line and 10' from operable skylights. It can be install on the inside of the wall or on the exterior of the house. Alternative would be to install so called "ProVent" - as it is called in my region - which is legal in some states. "ProVent" is used in applications where it is impossible to run vent through the roof. If your contractor terminated your vent inside the wall area than your sewer will vent into the wall.
  Reply With Quote
 
     
 
 
Old Jun 26, 2008, 02:49 AM   #9  
massplumber2008
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 2,614
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
Milo:

Vents terminate at between 18 and 24 inches above roof in my area....You must be in a warmer climate...??

Further, so future posters are clear, in my code book (Massachusetts, Uniform State Plumbing Code, 93), "No vent terminal shall be located directly BENEATH any door, window, or other ventilating opening of the building or of an adjacent building NOR shall any such vent terminal be within TEN FEET horizontally of such an opening unless it is at least TWO FEET above the top of such opening"...

All the different code books across this country drive me crazy sometimes. Here, when it comes to numbers, I've learned to temper almost everything I suggest with...IN MY CODEBOOK.....or IN MY AREA....or I will in fact state that the asker needs to check the code requirement or call the plumbing inspector in their area.

Not required by any means...Just FYI... Have a good day!

And ERIC...a provent is the same thing as the AAV You and Tom already discussed in great detail...just so you know...

Mark
  Reply With Quote
 
     
 
 
Old Jun 27, 2008, 05:15 AM   #10  
speedball1
Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 13,188
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Here in the Tampa Bay Area we terminate our vents 6 to 8 inchers above the roof line. Regards, Tom
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
exterior plumbing stack vents ccorriher Plumbing 7 May 12, 2008 03:30 PM
vent pipe turned into drain pipe and drain pipe into vent pipe chad278 Plumbing 3 Nov 6, 2007 06:29 PM
Plumbing Vent Gorenh Plumbing 3 Sep 13, 2007 04:01 PM
How do I cut through exterior wall to add second bathroom sink plumbing? kristinchase Plumbing 1 May 2, 2007 01:57 PM
Soil Stack Vent Pipe/Stench Pipe ( Smelly Drains ) midboy Plumbing 3 Sep 28, 2006 11:34 AM