Ask Experts Questions for FREE Help!
  Advanced
Register  |  Log in  
   Ask    
 Answer  
  Help  

Ask QuestionsprogressAnswer QuestionsprogressBuild ReputationprogressBecome an Expert
 
Free Answers in 3 Easy Steps

Register Now
3 Steps

At Ask Me Help Desk you can ask questions in any topic and have them answered for free by our experts. To ask questions or participate in answering them you must register for a free account. By registering you will be able to:
  • Get free answers from experts in any of our 300+ topics.
  • Accept money for answers that you provide.
  • Communicate privately with other members (PM).
  • See fewer ads.

Home > Home & Garden > Plumbing   »   exterior plumbing stack vents

 
Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Oct 2, 2007, 07:06 PM
ccorriher
New Member
ccorriher is offline
 
Join Date: Oct 2007
Posts: 6
ccorriher See this member's comment history on his/her Profile page.
exterior plumbing stack vents

How far from above operable doors and windows should exterior plumbing stack vents be?

Reply With Quote
 
     

Answers
 
 
Old Oct 2, 2007, 07:13 PM   #2  
CaptainRich
Cars & Trucks Expert
CaptainRich is offline
 
CaptainRich's Avatar
 
Join Date: Apr 2007
Location: Pale Blue Dot
Posts: 4,426
CaptainRich See this member's comment history on his/her Profile page.CaptainRich See this member's comment history on his/her Profile page.CaptainRich See this member's comment history on his/her Profile page.CaptainRich See this member's comment history on his/her Profile page.
Quote:
Originally Posted by ccorriher
How far from above operable doors and windows should exterior plumbing stack vents be?
http://www.askmehelpdesk.com/other-s...board-b-u.html

Comments on this post
ccorriher disagrees: Did not answer at all.
labman agrees: Sounds like a great answer to me. I hope you can't be certified as a home inspector based on a take home test.
KBC agrees: This is right on!!!
  Reply With Quote
 
     
 
 
Old Oct 2, 2007, 07:24 PM   #3  
CaptainRich
Cars & Trucks Expert
CaptainRich is offline
 
CaptainRich's Avatar
 
Join Date: Apr 2007
Location: Pale Blue Dot
Posts: 4,426
CaptainRich See this member's comment history on his/her Profile page.CaptainRich See this member's comment history on his/her Profile page.CaptainRich See this member's comment history on his/her Profile page.CaptainRich See this member's comment history on his/her Profile page.
ccorriher disagrees: Did not answer at all
You aren't doing your own homework!!!

Comments on this post
speedball1 agrees: Rich. What makes you think this was a homework question? i've gone through his posts band he sounds like s DIY selfer to me
  Reply With Quote
 
     
 
 
Old Oct 2, 2007, 09:48 PM   #4  
KBC
Senior Member
KBC is offline
 
KBC's Avatar
 
Join Date: Sep 2007
Location: Illinois
Posts: 913
KBC See this member's comment history on his/her Profile page.
Send a message via Yahoo to KBC
How do you think all these people got their answers,ccorriher?

We all worked,studied,and have done the due diligence ON OUR OWN!!!

Please,If you are going to be a productive member of society,do your part and learn like we did.
Honestly,sincerely yours,
KBC
  Reply With Quote
 
     
 
 
Old Oct 3, 2007, 07:46 AM   #5  
speedball1
Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 12,717
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by ccorriher
How far from above operable doors and windows should exterior plumbing stack vents be?
Chapter 14,section 1404.4 (Location of vent terminal) Of the Standard Plumbing Code reads," No vent terminal from a drainage system shall be located directly beneath any, door, window, or any other ventilating opening of the building or of a adjacent building, nor shall any such vent terminal be within 10 feet horizontally of such opening unless it is at least 2-feet above the top of such opening." This should answer your question. Good luck, Tom
  Reply With Quote
 
     
 
 
Old May 12, 2008, 05:05 AM   #6  
WDMsales
New Member
WDMsales is offline
 
Join Date: May 2008
Posts: 2
WDMsales See this member's comment history on his/her Profile page.
Exterior plumbing stack vents should be how far above operable doors & windows?

Comments on this post
speedball1 disagrees: what part of my above awswer do you not understand
  Reply With Quote
 
     
 
 
Old May 12, 2008, 10:17 AM   #7  
speedball1
Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 12,717
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
For the benefit of WDMsale, who seemed to have completely missed the above post, here it is again.
Quote:
Originally Posted by ccorriher
How far from above operable doors and windows should exterior plumbing stack vents be?

Chapter 14,section 1404.4 (Location of vent terminal) Of the Standard Plumbing Code reads," No vent terminal from a drainage system shall be located directly beneath any, door, window, or any other ventilating opening of the building or of a adjacent building, nor shall any such vent terminal be within 10 feet horizontally of such opening unless it is at least 2-feet above the top of such opening." This should answer your question.
  Reply With Quote
 
     
 
 
Old May 12, 2008, 03:30 PM   #8  
speedball1
Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 12,717
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
I attempt to be polite when answering questions but sometimers it's not all that easy when the feedback sounds like this.
Quote:
Private Message: ANSW to vent stack
Today, 06:06 PM
WDMsales
New Member Join Date: May 2008
Posts: 2


ANSW to vent stack

--------------------------------------------------------------------------------

I asked for the answer to a legitimate question. I DIDN'T ask for your attitude. What part of that do YOU not understand?
I can't DUMB this down any more then I have already. I posted the regulations direct from my code book twice already and here you are again, asking the same question. I'll do it one last time;
Chapter 14,section 1404.4 (Location of vent terminal) Of the Standard Plumbing Code reads," No vent terminal from a drainage system shall be located directly beneath any, door, window, or any other ventilating opening of the building or of a adjacent building, nor shall any such vent terminal be within 10 feet horizontally of such opening unless it is at least 2-feet above the top of such opening."
Now if that doesn't make sense perhaps you can get a fith grader to explain it to you. This should conclude our discourse. Tom
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Frozen Plumbing Vents in the Arctic Hudineker Plumbing 4 Feb 4, 2008 07:21 AM
Exterior Cast Iron Waste Stack rojo43 Plumbing 2 Sep 13, 2007 07:43 AM
Plumbing vents mikasa Plumbing 9 May 26, 2007 06:37 AM
How do I cut through exterior wall to add second bathroom sink plumbing? kristinchase Plumbing 1 May 2, 2007 01:57 PM
Plumbing vent stack requirements kwood Plumbing 2 Aug 28, 2006 05:58 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 08:54 PM.

Content Relevant URLs by vBSEO 3.0.0 RC6 © 2006, Crawlability, Inc.