Question
 | |  | | | 
Jun 27, 2009, 11:24 AM
| | New Member | | Join Date: Jun 2009
Posts: 7
| | | Electric Water Heater Shutting Off My electric water heater occasionally shuts off, I wake up in the morning and there is no hot water. It has not tripped the breaker, but when I shut the breaker off and turn it on again, after awhile there is hot water again. It had happened only a few times over the past three years, but has happened now three times in the past week.
I don't know if it is an issue with the heater or some wiring issue, so I don't know how to go about telling the landlord what type of service person I need.
thanks for your thoughts. | | | | | | |
Answers
 | |  | | |
Jun 27, 2009, 11:49 AM
|
#2
| | | Senior Plumbing Expert
Join Date: Jan 2003 Location: Sarasota, Fl.
Posts: 18,995
Pay to call speedball1 for advice ($.95/min) | What's the temperature setting? it should be close to 120F. There's another breaker on the upper thermostat. It's located behind the upper inspection panel. The next time you heater shuts off open the panel up and press the red button. Did that turn the heater back on? Let me know, Tom |
| | | | | | |  | |  | | |
Jun 27, 2009, 12:56 PM
|
#3
| | New Member
Join Date: Jun 2009
Posts: 7
| Quote:
Originally Posted by speedball1 What's the temperature setting? it should be close to 120F. There's another breaker on the upper thermostat. It's located behind the upper inspection panel. The next time you heater shuts off open the panel up and press the red button. Did that turn the heater back on? Let me know, Tom | hi tom
i don't know where the temperature setting is..there are two panels on the heater, one high and one low. just to clarify, the way i have been resetting is from the main breaker, not from the heater itself. it is a john wood pro series electric heater. i have been trying to ascertain the age of the heater, i suspect it is old. the canadian registration number OG18935C doesn't indicate a date.
when it goes off again i will try the reset you suggest and get back to you. |
| | | | | | |  | |  | | |
Jun 27, 2009, 02:58 PM
|
#4
| | | Senior Plumbing Expert
Join Date: Jan 2003 Location: Sarasota, Fl.
Posts: 18,995
Pay to call speedball1 for advice ($.95/min) | Open both panels and check the settings. Has your water been too hot lately? |
| | | | | | |  | |  | | |
Jun 27, 2009, 03:14 PM
|
#5
| | New Member
Join Date: Jun 2009
Posts: 7
| Quote:
Originally Posted by speedball1 Open both panels and check the settings. Has your water been too hot lately? | hi, i checked the settings, apparently the factory setting for this heater is 140, and that is where it is set. i haven't notice the water being hotter, but it has always been hot.
your message has something about clicking "on the scales" to comment, i don't see that anywhere as an option but my comment is that you are being very helpful to walk me through this. thank you. |
| | | | | | |  | |  | | |
Jun 27, 2009, 08:56 PM
|
#6
| | Ultra Member
Join Date: Jun 2008 Location: So. California
Posts: 3,736
| You may have 1 or 2 thermostats, one under each plate. Also, there is a large red reset button. |
| | | | | | |  | |  | | |
Jun 28, 2009, 04:12 AM
|
#7
| | | Senior Plumbing Expert
Join Date: Jan 2003 Location: Sarasota, Fl.
Posts: 18,995
Pay to call speedball1 for advice ($.95/min) | Quote: |
apparently the factory setting for this heater is 140,
| The factory setting for a new water heater is 120F. However, a setting of 140 shouldn't trip the breaker. If I were on the job the first thing I would do is take my Amp Probe and check the amperage on the elements . With a 4500 Watt element you should be pulling about 19 Amps. If they check OK the next thing I would check is the breaker itself. You're gonna find the problem at one of three places.
1) the elements
2) the thermostats
3) the breaker
Good luck, Tom |
| | | | | | |  | |  | | |
Jun 28, 2009, 05:18 AM
|
#8
| | Home Improvement & Construction Expert
Join Date: Jan 2008 Location: Alex, VA
Posts: 4,124
| If resetting the breaker gets you hot water, I would say that you have a weak breaker.
Some breakers move sufficiently to be obvious when tripped. Some hardly move at all. This type feels spongy when pressed toward the on position.
While it is not all that common, a breaker can be defective or become weak over a period of time and trip even though there is no over current.
From you description I wold say that you have a weak breaker. Replace. |
| | | | | | |  | |  | | |
Jun 28, 2009, 01:03 PM
|
#9
| | New Member
Join Date: Jun 2009
Posts: 7
| Quote:
Originally Posted by Milo Dolezal You may have 1 or 2 thermostats, one under each plate. Also, there is a large red reset button. | thanks for your info there seem to be two saw the reset button also |
| | | | | | |  | |  | | |
Jun 28, 2009, 01:07 PM
|
#10
| | New Member
Join Date: Jun 2009
Posts: 7
| Quote:
Originally Posted by speedball1 The factory setting for a new water heater is 120F. However, a setting of 140 shouldn't trip the breaker. If I were on the job the first thing I would do is take my Amp Probe and check the amperage on the elements . With a 4500 Watt element you should be pulling about 19 Amps. If they check OK the next thing I would check is the breaker itself. You're gonna find the problem at one of three places.
1) the elements
2) the thermostats
3) the breaker
Good luck, Tom | thank you tom
since i started asking about this the heater is working normally, i will try the reset button on the heater itself next time it goes off and see what happens. i'll see if i can find somebody to come over and check the element, thermostats and breaker. |
| | | | | | | |
Search this Thread |