Question
 
 
#1  
Old Apr 16, 2006, 05:34 PM
Tommyp!972
Full Member
Tommyp!972 is offline
 
Join Date: Feb 2006
Posts: 300
Tommyp!972 See this member's comment history on his/her Profile page.
Drilled well pump question

i have a drilled well with the pump feeding a pressure tank(wx-202)...the pressures are set at 30/50psi...but when the well pump kicks in there are air bubbles that make my faucets sputter and spit...i suspected there was a air leak in the well pump to pressure tank line but wouldn't i hear a sucking sound if there is?...when the tank is under pressure there are no leaks that i can see...any clue folks...any advice will be appreciated...thanks..

Reply With Quote
 
     

Answers
 
 
Old Apr 17, 2006, 06:24 AM   #2  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,973
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Hi Tommy,

Your 20 gallon bladder tank should show a reading of 28 PSI with the pump shut off and the pressure bled down. ( I just thought I'd toss that in.) If there were a leak in the suction line from the well point up to t6he surface you wouldn't hear a thing. Air can only get sucked in the system from the suction line. Everything else from the pump to the rest of the system's pressure and you would see water from the leak. You need a pump man out there to check your lines. good luck. Tom
  Reply With Quote
 
     
 
 
Old Apr 17, 2006, 05:48 PM   #3  
Full Member
Tommyp!972 is offline
 
Join Date: Feb 2006
Posts: 300
Tommyp!972 See this member's comment history on his/her Profile page.
so what i should do is bleed the pressure tank of water and read the pressure...should be around 28psi..ok....is that the precharged pressure from the factory?if its lower than 28psi would that mean there is a leak in the bladder bag?its a brand new pressure tank not even 1 month old so i know its still covered under warranty in case i need it returned...thanks for any help
  Reply With Quote
 
     
 
 
Old Apr 18, 2006, 05:13 AM   #4  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,973
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Hi Tommy,
"so what i should do is bleed the pressure tank of water and read the pressure...should be around 28psi..ok....is that the precharged pressure from the factory?"
"The bladder tank precharge pressure should be set 2 pounds lower then the cut-in pressutr on your control box. In your case 28 PSI.

"if its lower than 28psi would that mean there is a leak in the bladder bag?"
No, you must reset the bladder pressure to the control box at the time of installation.

Om another note i'm going to put up a image of a shallow well system. Notice the larger suction pipe. If you have a leak anywhere in the line you would lose pressure and see bubbles in the water. good luck, Tom
  Reply With Quote
 
     
 
 
Old Apr 26, 2006, 12:11 AM   #5  
Full Member
Tommyp!972 is offline
 
Join Date: Feb 2006
Posts: 300
Tommyp!972 See this member's comment history on his/her Profile page.
Bad Check Valve in Well???

was trying to troubleshoot air bubbles being pumped by my well and came across this answer...the check valve in my drilled well pump may have gone bad....any truth to that?will that cause air bubbles to be drawn into my piping?thanks for any help...i would really like to get this fixed asap because i have a softner system ready to go and im worried the air bubbles will mess up the worikings of the softner..
  Reply With Quote
 
     
 
 
Old Apr 26, 2006, 10:18 AM   #6  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,973
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by Tommyp!972
was trying to troubleshoot air bubbles being pumped by my well and came across this answer...the check valve in my drilled well pump may have gone bad....any truth to that?will that cause air bubbles to be drawn into my piping?thanks for any help...i would really like to get this fixed asap because i have a softner system ready to go and im worried the air bubbles will mess up the worikings of the softner..


Hey Tommy,
If the check valve were bad this wouldn't interject bubbles in your water. If the check valve were bad you would lose prime evey time the pump built up the pressure and shut down and the pump would start right back up again.
I think the leak is in the suction line. Regards, Tom
  Reply With Quote
 
     
 
 
Old Apr 27, 2006, 07:29 PM   #7  
Full Member
Tommyp!972 is offline
 
Join Date: Feb 2006
Posts: 300
Tommyp!972 See this member's comment history on his/her Profile page.
would i have to pull the entire pump from the casing to check?
  Reply With Quote
 
     
 
 
Old Apr 28, 2006, 05:34 AM   #8  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,973
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Pumps are a separate trade in my area. All we have are sprinkler systems. However I've been exposed to pumps a bit. I believe there is a method where they pressure up the suction line to check for leaks or a faulty foot valve. This way the pipe will not have to be pulled out. Check with your local pump service man. Good luck, Tom
  Reply With Quote
 
     
 
 
Old Apr 28, 2006, 06:41 AM   #9  
Full Member
Tommyp!972 is offline
 
Join Date: Feb 2006
Posts: 300
Tommyp!972 See this member's comment history on his/her Profile page.
will do thanks
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
well pump/jet pump
(0 replies)
Heat pump question
(1 replies)
well pump
(2 replies)
Well pump Question
(2 replies)
Drilled Wire
(1 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 10:30 PM.