Ask Experts Questions for FREE Help!
Ask    ||    Answer
 
  Advanced  
 

Ask QuestionsprogressAnswer QuestionsprogressBuild ReputationprogressBecome an Expert
 
Free Answers in 3 Easy Steps

Register Now
3 Steps

At Ask Me Help Desk you can ask questions in any topic and have them answered for free by our experts. To ask questions or participate in answering them you must register for a free account. By registering you will be able to:
  • Get free answers from experts in any of our 300+ topics.
  • Accept money for answers that you provide.
  • Communicate privately with other members (PM).
  • See fewer ads.

Home > Home & Garden > Plumbing   »   Do I need to worry about a Lead Bend?

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Jun 19, 2008, 01:02 PM
charlieboston
New Member
charlieboston is offline
 
Join Date: Jun 2008
Posts: 3
charlieboston See this member's comment history on his/her Profile page.
Do I need to worry about a Lead Bend?

I have a slow running shower drain in my condo and my plumber wants to open the ceiling of the condo below me to replace the pipe. I've heard that there are lead bends and things in the pipes that make it dangerous to use a snake because they could damage the plumbing. Do I need to worry about this? As far as I can tell from internet searches, lead bends are for joining toilets to soil pipes.

Also, is it reasonable to open a ceiling to replace a pipe where we're not even sure that's where the clog is? Aren't there cameras for this kind of thing?

Thanks!

Reply With Quote
 
     

Answers
 
 
Old Jun 19, 2008, 01:51 PM   #2  
Home Improvement & Construction Expert
hkstroud is offline
 
Join Date: Jan 2008
Location: Alex, VA
Posts: 4,071
hkstroud See this member's comment history on his/her Profile page.hkstroud See this member's comment history on his/her Profile page.hkstroud See this member's comment history on his/her Profile page.hkstroud See this member's comment history on his/her Profile page.
First I would try one of these gadgets. A shower drain is one place where it should work. Next i would call a drain or sewer specilist i.e Rotor rooter. A shower drain should be 2" piping and a small snake should go thru the trap. Next I would read the master deed to the condo. This piping is probably part of the "limited common elements" once it leaves the plane of the top surface of the floor. If that is true, the piping belongs to the condo association. That means it's the association's problem. That doesn't mean that they will be anxious to fix it though.
  Reply With Quote
 
     
 
 
Old Jun 19, 2008, 02:04 PM   #3  
New Member
charlieboston is offline
 
Join Date: Jun 2008
Posts: 3
charlieboston See this member's comment history on his/her Profile page.
Which gadgets are you referring to? The snake?

Am I safe from lead bends in my shower?
  Reply With Quote
 
     
 
 
Old Jun 19, 2008, 03:18 PM   #4  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,873
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by charlieboston
I have a slow running shower drain in my condo and my plumber wants to open the ceiling of the condo below me to replace the pipe. I've heard that there are lead bends and things in the pipes that make it dangerous to use a snake because they could damage the plumbing. Do I need to worry about this? As far as I can tell from internet searches, lead bends are for joining toilets to soil pipes.

Also, is it reasonable to open a ceiling to replace a pipe where we're not even sure that's where the clog is? Aren't there cameras for this kind of thing?

Thanks!
If your condo has been built in the last 40 years I doubt very much if you have lead plunbing in your system.
Quote:
I have a slow running shower drain in my condo and my plumber wants to open the ceiling of the condo below me to replace the pipe.
And he wants to do this without snaking the drain first? Outrageous!! This should be a sinple 1 hour job the remove the strainer and snake the line. While it's true that lead closet bends used to be used years ago, (how old is your building) I haven't seen any of those foir a long time. As a matter of fact I don't know of any of the tounger plumbers that have lead working experience. The last time I panned out a custom tile shower in lead was back iun 1978. Ask for a different plumber. this one's either incompetent or is attempting to puff the job. Let me know what your decision is. Good luck, Tom
  Reply With Quote
 
     
 
 
Old Jun 19, 2008, 08:37 PM   #5  
New Member
charlieboston is offline
 
Join Date: Jun 2008
Posts: 3
charlieboston See this member's comment history on his/her Profile page.
Thanks for the information, speedball. The building was built in 1930, so there is definitely lead under the toilets, but I was not sure if I should worry about lead pipes or bends under the bathtub.

If it is the case that there is lead to worry about under the shower, how can I safely clear the clog without accidentally poking a hole in the lead?
  Reply With Quote
 
     
 
 
Old Jun 20, 2008, 04:55 AM   #6  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,873
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by charlieboston
Thanks for the information, speedball. The building was built in 1930, so there is definitely lead under the toilets, but I was not sure if I should worry about lead pipes or bends under the bathtub.
If it is the case that there is lead to worry about under the shower, how can I safely clear the clog without accidentally poking a hole in the lead?
Chances are you won't find lead drainage in the shower. more then likely the shower drain's either copper or cast iron. To tell, remove the strainer and check. If the metal's soft then you have a lead trap but I was around when lead closet bends were being used and can't remember any bathtubs having lead plumbing. However, back in those days we installed drum traps on bathtubs,(see image) and those won't let a snake by. For showers, in my area, we used a Cast iron "P" trap. Good luck, Tom
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
Lead closet bend flared over unsecured brass flange
(3 replies)
ok to use rotor rooter if toilet has lead bend?
(3 replies)
Should I replace lead bend of toilet?
(1 replies)
Lead Bend Toilet Flange
(4 replies)
lead bend
(7 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 01:38 AM.