    Connector for NPT connection on shower, slip fitting or not?
    I'm installing the shower valve. Is it better to use a threaded slip fitting, or just a standard non-slip type? My worry is if I don't tighten the non-slip type enough, it will leak and I won't be able to tight anymore without undoing all the plumbing.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Oct 29, 2007, 01:10 PM
    We're going to hafta get together on terms. To me a threaded slip fitting is a adapter with male or female threads on one end and the other is a open end that slips onto a copper pipe where it it will be soldered. I think you may be referring to a compression fitting. I have never advised,( and some local codes forbid) installing compression fittings inside the wall line. We use 1/2" MIP to slip copper adapters. These will screw into the shower valve inlets and solder on to the coppere supplies. Good luck, Tom
    mtnbkr's Avatar
    mtnbkr Posts: 83, Reputation: 2
    Junior Member
     
    #3

    Oct 29, 2007, 03:21 PM
    Quote Originally Posted by speedball1
    We're gonna hafta get together on terms. To me a threaded slip fitting is a adapter with male or female threads on one end and the other is a open end that slips onto a copper pipe where it it will be soldered. I think you may be referring to a compression fitting. I have never advised,( and some local codes forbid) installing compression fittings inside the wall line. We use 1/2" MIP to slip copper adapters. These will screw into the shower valve inlets and solder on to the coppere supplies. Good luck, Tom

    I'm using CPVC if that matters. The adapters I need will be threaded on one end, and then solvent weld-able to CPVC on the other. The two types I'm referring to are slip, which allow for tightening of the threaded side, after solvent welding. And the other type is non-slip, where the threads are fixed to the solvent weld end.

    Sorry if this doesn't make sense. For either adapter, they have the same connections at the end.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Oct 30, 2007, 07:37 AM
    The two types I'm referring to are slip, which allow for tightening of the threaded side, after solvent welding. And the other type is non-slip, where the threads are fixed to the solvent weld end.
    Your slip fitting sounds a lot like a compression fitting to me. For CPVC we thread the adapter into the shower valve and glue the raiser to it. So I guess you would use the non-slip type. Good luck, Tom
    mtnbkr's Avatar
    mtnbkr Posts: 83, Reputation: 2
    Junior Member
     
    #5

    Oct 30, 2007, 08:54 AM
    How do you ensure that you've tightened the adapter enough? I'm worried that once I've tightened that, then glued, I won't be able to tighten since it will rotate the riser.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #6

    Oct 30, 2007, 09:50 AM
    Any plumber knows when to stop cranking down on threads. Wrap a few turns of Teflon tape around the threads and crank them down until you can't tighten any more. I'd trust the threads to hold pressure over time a lot more then I would a compression joint. Remember, this is pressure we're speaking of. For pressure I prefer a solid connection. For drainage I use both a solid and compression fitting. Regards, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Compression fitting in wall and water heater connection [ 11 Answers ]

So from what I gather, it sounds like it's not recommended for in wall application. I guess I don't really need it to be in wall, and can just leave it unfinished. Just trying to hear what people think. Any code problems in Maryland? Now for the water heater. What I'm trying to do is move my...

Shower push-in connector problem [ 2 Answers ]

Hi, I'm trying to install a new electric shower unit, it has a type of connector to the mains water called a 'push-in' connector. No matter what I try this seems to leak. The instructions just skip over it, and don't give any more instruction than how to disconnect it. I can see how it's...

Leaded fitting in shower [ 3 Answers ]

I'm replacing a shower.. the old pan drain is leaded to the drain pipe. How do I remove the lead? What is the easiest way to proceed? Can I do this myself, or do I need a plumber? Thanks for your help.

Ips vs. Npt [ 1 Answers ]

Are NPT and IPS the same standard in thread sizing?

Shower Drain Connection [ 4 Answers ]

I'm looking for feedback on replacing my exixting shower drain. SHOWER - 1 piece fiberglass STUBUP - 2" ABS CURRENT CONNECTION- Brass hub w/Oakum and lead (Leaking) ALIGNMENT ISSUE- The stubup is likely slightly out of plumb in relation to the drain as the trap is butted right against the...


View more questions Search