Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Nov 26, 2007, 03:45 PM
mtetter
New Member
mtetter is offline
 
Join Date: Nov 2007
Posts: 6
mtetter See this member's comment history on his/her Profile page.
Connecting a tankless water heater and seperate hot water heater

What I have is this. An oil fired boiler that generates hot water for my house baseboard heating system. Contained within the boiler is a tankless heater that is heated by way of the firebox in the boiler. The tankless heater is used only for domestic hot water. It has a seperate CW supply to the heater and is not in any way connected to the house baseboard heating system. The hot water exits the tankless heater and into a mixing valve and thence to the house plumbing fixtures. This is the only hot water source for the house and therefore the boiler has to run 365 days/year. I would like to install a NEW electric hot water heater and pipe it into the existing cold water supply and the existing domestic hot water to provide hot water during the summer months and turn off the boiler, thereby avoiding the $800.00 fuel oil bill that I incurr for the summer. I can pipe the EWH into the existing system with values to bypass the boiler tankless heater. What I need help in doing is how to pipe the system and still use the boiler tankless heater as well as the EWH during the winter months. I invision a HW pipe from the tankless heater into the CW supply of the EWH. Would I need a check valve to prevent HW from back feeding into the CW system? Your help in resolving this situation would be appreciated.

mtetter

Reply With Quote
 
     

Answers
 
 
Old Nov 26, 2007, 05:01 PM   #2  
ballengerb1
Home Repair & Remodeling Expert
ballengerb1 is offline
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 8,142
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
You just need to create a loop after the boiler where you install the new heater. The CW always flows to the boiler and in the winter its heat, in summer it isn't. When the water leaves the boiler you should install a three valve manifold like the ones used for a water softner. In the summer the horizontal valved is closed and the two verticles open to allow CW to enter the heater and the exit. In the winetr the horizontal is open and the verticles closed, no need for a check valve.
  Reply With Quote
 
     
 
 
Old Nov 27, 2007, 04:52 AM   #3  
mtetter
New Member
mtetter is offline
 
Join Date: Nov 2007
Posts: 6
mtetter See this member's comment history on his/her Profile page.
ballengerb1

I'm not familiar with the 3 valve manifold. How is it piped?

mtetter
  Reply With Quote
 
     
 
 
Old Nov 27, 2007, 05:14 AM   #4  
speedball1
Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 12,717
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by mtetter
ballengerb1

I'm not familiar with the 3 valve manifold. How is it piped?

mtetter
I think what Bal is referring to is a three valve bypass,(see image) and not a manifold. This will allow you to cut in or cut out the new water heater. Good luck, Tom
Attached Images
File Type: pdf Softener Bypass.pdf (225.7 KB, 39 views)
  Reply With Quote
 
     
 
 
Old Nov 27, 2007, 07:33 AM   #5  
ballengerb1
Home Repair & Remodeling Expert
ballengerb1 is offline
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 8,142
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
Tom, thanks for the graphics. Do you think my ideas will meet his needs?
  Reply With Quote
 
     
 
 
Old Nov 27, 2007, 10:19 AM   #6  
mtetter
New Member
mtetter is offline
 
Join Date: Nov 2007
Posts: 6
mtetter See this member's comment history on his/her Profile page.
ballengerb1

The graphic does not really help. I do understand that connection.

I want the EWH to be in the circuit with the boiler tankless heater in the winter months and the boiler tankless heater out of the circuit in the summer months. I want to use the HW from the tankless heater in the winter since the boiler will be running for the house B/B heat. I invision a couple of check valves where the HW from the tankless heater would tie into the CW supply of the EWH and also a check valve at the tankless heater to prevent CW from back feeding into the tankless heater in the winter time. What do you think?

mtetter
  Reply With Quote
 
     
 
 
Old Nov 28, 2007, 06:46 AM   #7  
ballengerb1
Home Repair & Remodeling Expert
ballengerb1 is offline
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 8,142
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
Tom gave a hand drawn view of a soft water by-pass valve and this should work. The valve would be above your tankless heater. By operating the valves the way I mentioned in my earlier post you will have you two isolation loops. The check valves are not neccessary since the water will simply flow through the shut down bolier without no significant problems at all.
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
tankless water heater Desert Runner Plumbing 5 Nov 9, 2007 09:04 AM
tankless water heater pnguyen Plumbing 7 Nov 3, 2007 06:22 PM
Tankless water heater Georgia23 Appliances 2 Apr 24, 2007 07:12 PM
tankless water heater havana Plumbing 2 Dec 14, 2006 06:51 AM
tankless water heater vs. regular water heater happybisaya Plumbing 9 Jan 11, 2006 10:32 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 08:47 PM.

Content Relevant URLs by vBSEO 3.0.0 RC6 © 2006, Crawlability, Inc.