Question
 
 
#1  
Old Apr 9, 2008, 05:14 PM
zjclucky
New Member
zjclucky is offline
 
Join Date: Apr 2008
Posts: 8
zjclucky See this member's comment history on his/her Profile page.
Compression Union Leakage

I have a Compression Union, which connects two pieces of pipes. One joint leaked, because nut loosed. I unscrewed the loosed nut, applied “pipe thread sealant”, then tightened the nut very tightly. The leak stopped about half an hour. Then leakage started again and water came out from the nut, although the leakage was much slower than before.

Any idea of how to fix this problem? Why the new leakage did not start immediately after I tightened the nut?

Thanks a lot.

Reply With Quote
 
     

Answers
 
 
Old Apr 9, 2008, 05:36 PM   #2  
KeepItSimpleStupid
Engineering & Electronics Expert
KeepItSimpleStupid is offline
 
KeepItSimpleStupid's Avatar
 
Join Date: Aug 2007
Posts: 3,784
KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.
Inspect the union very carefully for a hairline thread crack.

Pipe thread sealer should not be used on compression fittings. The sealing surface is not on the threads.
  Reply With Quote
 
     
 
 
Old Apr 9, 2008, 07:34 PM   #3  
zjclucky
New Member
zjclucky is offline
 
Join Date: Apr 2008
Posts: 8
zjclucky See this member's comment history on his/her Profile page.
Thank you very much.

Will the Compression Ring crack if I tighten the Compression nut too tightly?

Can the crack of Compression ring cause the leakage?
  Reply With Quote
 
     
 
 
Old Apr 9, 2008, 07:51 PM   #4  
Flying Blue Eagle
Senior Member
Flying Blue Eagle is offline
 
Join Date: Aug 2007
Location: TENNESSEE
Posts: 846
Flying Blue Eagle See this member's comment history on his/her Profile page.Flying Blue Eagle See this member's comment history on his/her Profile page.
Zjclucky - Yes if you tighten it to far, you can also be putting a small kink in the pipe is why you are not getting a good seal . You did not say ( WHAT KIND OF PIPE YOU ARE WORKING WITH????????) .That would help us alot to know, If its copper and is not real stright where you are putting the compression fitting then that could be the causeand you could have tightened the fitting so tight that it cracked the copper pipe . SO TELL US WHAT KIND OF PIPE YOU ARE WORKING WITH ?????? GOOD Luck & GOD BLESS .::: Hello Kiss
  Reply With Quote
 
     
 
 
Old Apr 9, 2008, 08:58 PM   #5  
zjclucky
New Member
zjclucky is offline
 
Join Date: Apr 2008
Posts: 8
zjclucky See this member's comment history on his/her Profile page.
Thank you very much. Yes, it is copper pipe and not straight.

But if I had cracked the pipe, a lot of water should have rushed out right away. Actually now the leakage is very slow.

What really confused me is that after I tightened the nut following the first big leakage, the leakage STOPPED FOR ABOUT HALF AN HOUR before it started again, although the second leakage was much slower than before. Why the second slow leakage did not happen immediately after I tightened the nut?
  Reply With Quote
 
     
 
 
Old Apr 10, 2008, 02:00 AM   #6  
KeepItSimpleStupid
Engineering & Electronics Expert
KeepItSimpleStupid is offline
 
KeepItSimpleStupid's Avatar
 
Join Date: Aug 2007
Posts: 3,784
KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.
Quote:
Originally Posted by zjclucky
But if I had cracked the pipe, a lot of water should have rushed out right away.

Not necessarily true. Had one suddenly gush water about a month later. It's called stress.
Water flow and temperature changes cause minute movements.

How big is the pipe?

Compression fitting - Wikipedia, the free encyclopedia

Compression Fittings
  Reply With Quote
 
     
 
 
Old Apr 10, 2008, 06:49 AM   #7  
zjclucky
New Member
zjclucky is offline
 
Join Date: Apr 2008
Posts: 8
zjclucky See this member's comment history on his/her Profile page.
Thank you very much.

1/2" inch copper pipe.
  Reply With Quote
 
     
 
 
Old Apr 10, 2008, 07:17 AM   #8  
KeepItSimpleStupid
Engineering & Electronics Expert
KeepItSimpleStupid is offline
 
KeepItSimpleStupid's Avatar
 
Join Date: Aug 2007
Posts: 3,784
KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.
Actually, the "copper pipe" used in the home is really "copper tubing" and I purposely used your terms. It comes in K, L or M grades which is the wall thickness and intended use.

The outside diameter of pipe and tubing are very different. It's somewhat complex. It's Schedule rating determines the wall thickness. Schedule 40 is the most common.

It's very important to get compression right the first time. Square (both the end of the tubing and the intended final position), burr free, clean and fitted tightly in the fitting before tightening the nut. Don't overtighten.
  Reply With Quote
 
     
 
 
Old Apr 10, 2008, 08:19 AM   #9  
zjclucky
New Member
zjclucky is offline
 
Join Date: Apr 2008
Posts: 8
zjclucky See this member's comment history on his/her Profile page.
Thank you very mcuh.
  Reply With Quote
 
     
 
 
Old Apr 10, 2008, 08:55 AM   #10  
speedball1
Plumbing Expert
speedball1 is online now
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 12,706
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
it is copper pipe and not straight.
To form, a perfect fit the pipes should be in line with oneanother. If they are cocked the connection won't be completely together leaving a small gap. Line the two pieces up and try again. good luck, Tom
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Coolent leakage veronv Cars & Trucks 14 Oct 22, 2007 09:44 AM
AC leakage austinz Heating & Air Conditioning 1 Jun 28, 2007 01:03 PM
breast leakage sexykatasha Women's Health 3 Jun 23, 2007 08:44 AM
Shower leakage mrcdraph Interior Home Improvement 1 May 24, 2007 07:18 AM
Union and non-Union works Trunkdk Labor Unions 2 Sep 25, 2005 06:46 PM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 09:54 AM.

Content Relevant URLs by vBSEO 3.0.0 RC6 © 2006, Crawlability, Inc.