    Can you replace a 4 inch cast iron soil stack with 3 inch pvc?
    I recently purchased a home built (I'm guessing) in the early 1900's. I noticed a leak in my basement coming from the old 4 inch cast iron soil stack running from my second floor bathroom to the basement. There is water dripping down the pipe to the basement. Three plumbers have come out to diagnose the problem. The first plumber removed the commode and cut a bigger hole in the floor to try and find where the pipes begin and end. There was also a hole cut in the floor on the other side of the wall (in the closet in the hall around the corner from the bathroom) to follow the pipes from the bathroom leading to the soil stack which then travels down through my kitchen/dining room wall to the basement. There is a lot of deterioration in my pipe at the second floor level (several holes are visible) but that is not where the leak is. Several of the plumbers believe the cast iron is cracked in the kitchen/dining room wall. The entire pipe needs to be replaced/upgraded. The plumber is thinking of putting 3 inch pvc instead of 4 inch because the 4 inch (fittings-I'm not sure?) will be a difficult fit. Is that okay to do?
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #2

    Jul 15, 2010, 05:38 PM
    There is always a way to connect 4" PVC to 4" Cast Iron and we do exactly that on everyday basis. If you post a photo of the proposed PVC to C.I. connection, I will tell you exactly what fitting to use.

    Back to you... Milo
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Jul 17, 2010, 06:53 AM

    I am replacing all the old cast iron with PVC. The cast iron is 4 inch, but the PVC that will be replacing it is only 3 inch. I just wanted to make sure there wasn't any plumbing code that says it should be at least 4 inch.
    Check with your Building Department. Different areas have different restrictions, Example!
    Then county I live in allows 3' above the pour and a 3" toilet branch under the slab connecting to a 4" house main but while the county just south of me mandates toilet branches under the slab be 4" to the main. I think you'll be OK with 3" above the slab but if you're replacing anything under the slab I'd check first. Good luck, tom
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #4

    Jul 17, 2010, 07:16 AM

    Hi all...

    In my area if you start 4" in the basement you MUST continue that 4" up and through to the roof.

    Your plumber isn't suggesting sticking 3" pipe inbetween the 4" headed to the basement and the 4" that goes up through the roof is he? If so, I am sure the plumbing code would not allow that... OK?

    As Tom said, talk to your local plumbing inspector... he'll have most accurate answer for you!

    Mark

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Outside cast iron stack in PA Want to replace with PVC [ 6 Answers ]

I just bought a house and it was build in the 1920s. The drainage stack is outside the house and it is starting to leak. I am trying to decide if I should just patch the leaks or replace it with PVC. I am not even sure if that would work. Any suggestions as to where I should start? Thanks

How do I connect a 2 inch cast iron pipe to PVC [ 1 Answers ]

I am converting a bath tub into a shower and I have to move the drain away from the wall. After cutting the cast iron pipe, I need to connect it to a PVC trap and extend it vertically for the next step. How do I do the connection? Thanks, Jalal

Converting from cast iron to pvc 4 inch [ 2 Answers ]

Hi I was wondering I have a 4 in cast iron that has a hole in it and I need to replace with pvc what would I do to replace I know some what about plumbing I just don't know anything about cast iron

Crack in Cast Iron Main soil stack [ 3 Answers ]

:confused: I just moved into a Bi-level house approx. 40-50 years old. It has a Cast Iron Main soil stack (main vertical sewer line). On the lower level I noticed that it has a crack that is approx 5"-6" long about 1/4" thick. Now I bought a new pluming book because of some other repairs I had...

Cast iron soil stack to pvc [ 15 Answers ]

the plumbing in our house is from 1936. We noticed a large stain in the ceiling, tore it out to reveal the cast iron soil stack (runs from the upstairs bathroom turns a corner then runs straight to the basement) and found the leak was around (very bad leak) the lead joint. My husband finally got...


View more questions Search