    Broken Concrete trap "Drainage Pipe"
    I recently bought a house with a unfinished basement bath. I have since decided to finish the bathroom but have ran into a bit of a problem. The previous owners set all of the drains up and I have since found a large hole in the trap of a secondary drain that drains into the main. To explain it better the toilet drain was directly tapped into the main and serves as no problem as water flows easily down the drain and the upstaris drains do not clog. The drains for the future sink and shower connect into a floor drain about 2 feet from the main. The floor drain drops abount 16 inches and has a trap that connects back up to the main drain. At the bottom of this trap is where the large hole about 2 inches wide by 2 inches long lays. The pipe is concrete on both sides and I don't know what is the best option for me. I could try and replace the trap or take the trap out and run the drain from the sink straight to the main with the floor drain running into it. So what is my best option and how do I cut the concrete pipe without causing further damage to the rest of the pipe?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Jan 24, 2007, 07:28 AM
    "The drains for the future sink and shower connect into a floor drain about 2 feet from the main."

    Would this be a hard connection or a indirect waste? If , as I suspect, this is a indirect waste terminating above the floor drain then no trap or vent will be necessary. However, if you connect direct to the main you''ll have to trap and vent both fixtures. Please explain. As for the hole in the trap, it should be replaced at once. The hole will drain the trap seal allowing sewer gas to enter your home. Regards, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Fan Blower not working in "ON" or "AUTO" in heat or AC [ 13 Answers ]

Got home from the Brewer game this afternoon and noticed the house was warm(78). Outside was 91. I checked the T-stat and it was set correct. Noticed the air vents weren't blowing anything. Went outside and the condenser and fan was running fine. Then I went downstairs to the furnace unit to see...

Tub to Shower 1.5" pipe to 2"pipe [ 6 Answers ]

Shower uses a 2" pipe. Tub used a 1.5 inch pipe. Bought a 2"pipe coupler... using the coupler to attach the new 2" pipe to the old 1.5 inch joint on the 3" main house drain pipe. The coupler has too much play on the 1.5 inch side... almost like it's an 1/8th of a inch smaller than 1.5. What's...

"approved coating" for LPG pipe fittings? [ 1 Answers ]

Hi: What are "approved coatings" for buried LPG gas pipe black iron fittings. The code only alludes to approved, but doesn't specify. In the Old days, it was 4 layers of 10-mil pipe wrap. but I'm wondering if there is some sort of liquid coating that can be applied (such as alphalt...

Is an "S" trap ever allowed? [ 4 Answers ]

The house we've just moved into has the piping for a full bathroom in the basement floor complete with an ejector pump. My intention is to put a washer\dryer and laundry sink in that area of the basement instead of a bathroom. There are 4 drain pipes running up from the floor. Three of the...


View more questions Search