Ask Experts Questions for FREE Help!
  Advanced
Register  |  Log in  
   Ask    
 Answer  
  Help  

Ask QuestionsprogressAnswer QuestionsprogressBuild ReputationprogressBecome an Expert
 
Free Answers in 3 Easy Steps

Register Now
3 Steps

At Ask Me Help Desk you can ask questions in any topic and have them answered for free by our experts. To ask questions or participate in answering them you must register for a free account. By registering you will be able to:
  • Get free answers from experts in any of our 300+ topics.
  • Accept money for answers that you provide.
  • Communicate privately with other members (PM).
  • See fewer ads.

Home > Home & Garden > Plumbing   »   Basement Remodel

 
Thread Tools Display Modes
Question
 
 
#1  
Old Jun 16, 2006, 09:48 PM
badejonge
New Member
badejonge is offline
 
Join Date: Jun 2006
Posts: 1
badejonge See this member's comment history on his/her Profile page.
Basement Remodel

I am in the process of redoing a basement bathroom in which I need to relocate all the drain locations to one extent or another. I would like to reuse the old 4" toilet drain if possible so that all the repaired concrete would get covered by tile. Where the new toilet is going to go is in the SW corner, if I can tie into the old line I would need to run from the new toilet 4' to the NE to the old one and then tie in with a wye/tee (more on that in a bit). From there I can see that the old line ran to the NW. Everything from here is an educated guess based on the direction I can see the drain lines initially heading ( I have the floor removed in an 18" square around them) The old pipe runs to the NW, as I said, 3' or so then ties in with a wye/tee with the sinks 2" line. After tying together they head to the SW 5-6' and then wye/tee with another 2" drain coming from the upstairs kitchen sink which also has a vent. They then head to the West 12 foot the main stack which also has a vent. If you follow all that it would make a big U-turn NE,NW,SW, then W.

Would that matter as long as it has fall?

That first wye/tee that I mentioned is where I would like to tie in a 2" shower drain is that at all possible at that point?

Reply With Quote
 
     

Answers
 
 
Old Jun 17, 2006, 05:27 AM   #2  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 14,873
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
I'm Ok with the big return bend but if you're planing on a 4 X 2" combination wye and eighth bend, ( it's not a wye/tee) to pick up the shower you're going to have to run a vent for it. Code mandates that EVERY trapped fixture shall be vented. It also does not allow a major fixture, such as your toilet, to discharge past a unvented minor one, such as your shower. You may revent the shower vent back into a existing dry vent if you wish.
Good luck, Tom
  Reply With Quote
 
     

Bookmarks


Thread Tools
Display Modes

 
Similar Sponsors

Similar Threads
Question Asker Forum Answers Last Post
basement bathroom remodel stealeyl Plumbing 1 Sep 2, 2006 11:01 AM
Basement bath remodel Dale Roach Plumbing 0 Jul 21, 2006 06:08 AM
remodeling a remodel mch Electrical & Lighting 3 Jun 5, 2006 04:56 AM
Remodel Question speedball1 Plumbing 3 Nov 13, 2005 12:10 PM
Big Bathroom Remodel trbo20 Plumbing 2 Aug 2, 2004 06:50 AM




Copyright ©2003 - 2007, Ask Me Help Desk.