Home > Home & Garden > Plumbing   »   Basement Rough in---Brian

 
Thread Tools Display Modes
Question
 
 
#1  
Old Dec 2, 2005, 12:35 PM
speedball1's Avatar
speedball1
Plumbing Expert
speedball1 is offline
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 13,776
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Call speedball1 via Skype™
Basement Rough in---Brian

Hey Tom/speedball,

I saw you had answered a question online regarding some basement plumbing and I had a few questions myself.

I dug a trench and hole for my basement as the image will show. I was curious as to what I will need to do to ensure things are properly vented and sized. I wanna say the main line is 3" but maybe 4" regardless here goes....

Shower - What size is doable? Should this use a buried or sub foundation level P-Trap? Is there a danger in buring this P-Trap to far? A scenerio in which water weight couldn't force the water out?

Sink - Seems pretty standard as it's above ground.

Toilet - Is there such a thing as a directional Tee?
Seems from what I've seen the Tees curve in a certain direction.
Is this what I should use to prevent flow in the wrong direction?
Is there such a thing as a check valve like set-up I should put in the main prior to the toilet connection?
Doesn't the toilet have it's own built in P-Trap?

Do you see any problems in my drawing there?

Any help would be fantastic!!!!!!

Cheers
-brian-

Reply With Quote
 
     

Answers
 
 
Old Dec 2, 2005, 01:51 PM   #2  
Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 13,776
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Hi Brian,


(1) Shower--What size is doable? Should this use a buried or sub foundation level P-Trap?

2" pipe and "P" trap. trap's buried underthe cement and a 2" raiser brought up through the cement to pick up the shower drain. The shower drain wi8ll connect to the lavatory drain and be wet vented.

(2)Sink - Seems pretty standard as it's above ground.

Except you will run a vent to the roof off the 2 X 1 1/2" tee you pick it up with.

(3)"Toilet - Is there such a thing as a directional Tee?
Seems from what I've seen the Tees curve in a certain direction.
Is this what I should use to prevent flow in the wrong direction?
Is there such a thing as a check valve like set-up I should put in the main prior to the toilet connection?
Doesn't the toilet have it's own built in P-Trap?"

All drainage fittings direct the flow. You will be using DWV fittings.
No check valve's are needed in the drainage system.
The "P" trap's built into the toilet.
The slope is 1/4" to the foot.

You do realize that you're getting into major surgery here don't you? You'll need plumbing skills and knowledge to add a bathroom group from scratch.
You may want to pay a plumber to come in and lay the job out and give you a material list. Lots of luck, Tom
  Reply With Quote
 
     


Thread Tools
Display Modes

 
Similar Sponsors

Similar Threads
Question Asker Forum Answers Last Post
Basement rough in BigDen Plumbing 5 Jun 26, 2007 07:15 PM
Basement rough-in swb001 Plumbing 3 Jan 27, 2006 03:51 AM
Basement rough-in: dap out armaraas Plumbing 12 Jan 5, 2006 02:51 PM
Basement rough in mblok Plumbing 3 Dec 28, 2005 02:41 PM
Basement rough in vz2d1k Plumbing 1 Nov 22, 2004 04:55 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 11:49 PM.