Question
 
 
#1  
Old Mar 9, 2006, 01:55 PM
camperpop
New Member
camperpop is offline
 
Join Date: Mar 2006
Posts: 2
camperpop See this member's comment history on his/her Profile page.
2nd floor bathroom

Wanted to add a 2nd floor bathroom. I have a 4" DWV from roof to first floor bath. The whole house is on a slab. Needed to know if I can tie into the 4" pipe for the toilet,sink and shower on the 2nd floor. The 2nd floor toilet is right above the first floor toilet. I here stories that when I flush the 2nd floor toilet that it will cause a vacum in the first floor toilet. Others say it will work fine being a 4" pipe.

Reply With Quote
 
     

Answers
 
 
Old Mar 9, 2006, 02:48 PM   #2  
Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 13,785
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by camperpop
Wanted to add a 2nd floor bathroom. I have a 4" DWV from roof to first floor bath. The whole house is on a slab. Needed to know if I can tie into the 4" pipe for the toilet,sink and shower on the 2nd floor. The 2nd floor toilet is right above the first floor toilet. I here stories that when I flush the 2nd floor toilet that it will cause a vacum in the first floor toilet. Others say it will work fine being a 4" pipe.
You should be fine if you vent the lavatory and wet vent the tub/shower drain back to the lavatory drain. The second floor toilet should present no vacume on the first floor bathroom group as it will be well vented by both the main stack vent and the lavatory vent. You may revent the lavatory vent back to the main stack vent instead of running it out the roof if you wish.
regards, tom

Comments on this post
camperpop agrees: Thanks for the help to clear up my question. Thanks, Iam Tom too.
  Reply With Quote
 
     


Thread Tools
Display Modes

 
Similar Sponsors

Similar Threads
Question Asker Forum Answers Last Post
2nd floor bathroom leaked torrock81770 Plumbing 1 Aug 19, 2006 05:33 AM
Puddle on Bathroom Floor uglowgirl Plumbing 6 Jul 14, 2006 11:34 AM
Tile Bathroom Floor Cgirl Interior Home Improvement 4 May 5, 2006 06:38 AM
laying bathroom floor ki ki Interior Home Improvement 1 Apr 18, 2006 03:42 AM
2nd Floor Bathroom mikeposthumus Plumbing 3 Jan 20, 2006 10:09 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 05:54 PM.