Home > Home & Garden > Interior Home Improvement   »   how to insulate a cathedral ceiling in a house

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Dec 2, 2006, 03:54 AM
Karl Haughton
New Member
Karl Haughton is offline
 
Join Date: Dec 2006
Posts: 1
Karl Haughton See this member's comment history on his/her Profile page.
how to insulate a cathedral ceiling in a house

Please tell me how to insulate a catherdral ceiling

Reply With Quote
 
     

Answers
 
 
Old Dec 2, 2006, 06:56 AM   #2  
New Member
TorontoCarpenter is offline
 
Join Date: Dec 2006
Posts: 5
TorontoCarpenter See this member's comment history on his/her Profile page.
Quote:
Originally Posted by Karl Haughton
Please tell me how to insulate a catherdral ceiling
three rules to this answer.

1. air movement between the roof sheeting and roof framing members and the insulation at least 1 1/2 inches of air space for the air to circulate from the soffit ( the inlet ) to the ridge vent ( the outlet)
  Reply With Quote
 
     
 
 
Old Dec 2, 2006, 06:58 AM   #3  
Senior Member
skiberger is offline
 
Join Date: Nov 2005
Location: pennsylvania
Posts: 563
skiberger See this member's comment history on his/her Profile page.
First you need to install rafter vents. These are styrofoam vent section that you will staple to the under side of the roof sheathing from the eave area to the ridge. These are in the insulation area of the home centers.
These vents will allow an air gap so air can flow from the eave vents to the ridge vent.

Then install the the insulation with the paper side toward the living space. R19 to R25 is the standard insulation you'll be able to fit between a 2x6 & 2x8. If your rafters are 2x10 you can increase the insulation to a R30.
  Reply With Quote
 
     
 
 
Old Dec 2, 2006, 07:05 AM   #4  
New Member
TorontoCarpenter is offline
 
Join Date: Dec 2006
Posts: 5
TorontoCarpenter See this member's comment history on his/her Profile page.
R-21 is the minimum which is 5 1/2 inches, R-38 is the max 12 inches. And last thing which is very important 9mm poly, and tape the seems with tyvek tape. keeps moist warm air from getting into the insulation which will breed mold in that area.
  Reply With Quote
 
     
 
 
Old Nov 18, 2007, 01:42 PM   #5  
New Member
sandieft is offline
 
Join Date: Nov 2007
Posts: 1
sandieft See this member's comment history on his/her Profile page.
Quote:
Originally Posted by Karl Haughton
Please tell me how to insulate a catherdral ceiling
What do I do if I don't have a ridge vent because my cathedral ceiling butts up to the wall?
  Reply With Quote
 
     
 
 
Old Nov 18, 2007, 02:01 PM   #6  
New Member
TorontoCarpenter is offline
 
Join Date: Dec 2006
Posts: 5
TorontoCarpenter See this member's comment history on his/her Profile page.
Quote:
Originally Posted by sandieft
What do I do if I don't have a ridge vent because my cathedral ceiling butts up to the wall?
Not to worry, you can still vent out the sides mind you it still has to be close to the top of the roof where the wall and roof meet. You should cross vent the roof out the sides or one side either the left or right side. It's not as good as a ridge vent but it'll do the job just fine. Just remember to measure back off the wall 24 inches or so along the roof slop to install your vent to avoid the wall flashing and vent flashing from over lapping...good luck !
  Reply With Quote
 
     
 
 
Old Nov 21, 2007, 09:04 PM   #7  
Junior Member
TerryB is offline
 
Join Date: Nov 2007
Posts: 53
TerryB See this member's comment history on his/her Profile page.
Or, a false wall to continue the ventalation up to the the next roof.
  Reply With Quote
 
     
 
 
Old Feb 23, 2008, 06:18 AM   #8  
New Member
astrobiker is offline
 
Join Date: Feb 2008
Location: New Hope, PA
Posts: 2
astrobiker See this member's comment history on his/her Profile page.
There is a considerable amount of misinformation on the web about insulation of cathedral ceilings. There is a science to this that must be followed. There is no single, simple answer to this question because it depends on the climate zone you live in.

First, for the most complete answer, go to buildingscience.com and search. They give a full treatise on this topic.

The abbreviated answer is that the underside of the roof sheathing needs to be protected from moisture and condensation. However, many of the commonly accepted practices only answer part of the question or lead to unsatisfactory, partial solutions.

If you are venting under the sheathing
:
The purpose of venting is to allow a clear air flow to every cavity. In order for this to occur, you need: a) a clear passageway under the sheathing, preferably 2". 1" is too small even though it is often recommended; b) sufficient venting at soffit and ridge. Sufficient is defined as the area of the room below divided by 150 to 300 depending on the conditions. Safest is to shoot for 150. That is: room area / 150 equals square feet of venting.
So, for example, if you have a 500 square foot room, then you need approximately 3 square feet of venting area at the soffit and the roof. Many soffit and ridge vent systems are inadequate in this regard, providing vastly less area than this. See Cor-a-vent's website for details of venting. They have excellent documents describing proper venting.
Note that this precludes the "side venting" suggested by another poster unless you can figure out how to get 3 square feet of venting out the sides. Most people use those little 3" vent plugs that might have a square inch of air space, if you're lucky.

Note that this is NOT the case of "I can't do it completely, I'll do it partially". If you don't have enough area, then the air flow will be inadequate.
Also, another problem is that most cathedral ceilings have skylights. These are blocked areas that cannot be vented without cleverness.

If you are NOT venting under sheathing

Contrary to popular opinion, venting is not necessary, and can do more harm than good if not implemented properly. Remember, the key is to keep the roof sheathing from getting wet. Most moisture is carried by air movement. For example, a recessed light installed in a cathedral ceiling is roof rot ready made.
The best solution is to apply closed cell polyurethane spray foam directly to the underside of the roof sheathing. 2-3" is necessary in most climates, but see the Building Science literature for details. Closed cell polyurethane is a very effective vapor retarder when applied to these thicknesses. If moisture cannot reach the roof deck, you're in good shape (as long as the roofing above it is in good shape).
The advantage to this solution, as noted, is that internal warm humid air can't even touch the sheathing, so it will never condense. This air seals and insulated. So, if you install recessed lights in the sheetrock below, you're still protected. Every other solution fails when you have ceiling penetrations, especially if you place a vapor barrier like plastic sheeting in the ceiling. Since the vast majority of moisture movement is at penetrations. If you install plastic sheeting, the electrician will cut a big hole in it where the recessed light pokes through. Since all such fixtures leak, unless extremely carefully detailed (never done), the air will leak into the cavity. With normal insulation (fiberglass), this moisture then gets trapped in the cavity by the plastic, rotting out your roof unless you have ample air flow to carry the moisture away.

Another solution is to use dense packed cellulose. This is defined as ~3.5 pounds per cubic foot. Studies on thousands of homes (see Applegate insulation's website) have shown that fully filling the cathedral ceiling cavity minimizes air infiltration and provides a long lasting roof with good insulation. The key is that it has to be dense packed cellulose and there must be no venting into this space.

This just touches on a couple key considerations. To summarize:
If you're going to ventilate, you have to do it right
If you use fiberglass, you have to ventilate
If you use spray foam, you should not ventilate, nor should you use any other vapor barrier.
If you use dense packed cellulose, do not ventilate or use vapor barriers.

Comments on this post
TerryB agrees: Nicely Said
igloo98 agrees: Nicely detailed info. 40 years in Alaska ai have seen a lot of moisture damage!
  Reply With Quote
 
     
 
 
Old Dec 19, 2008, 10:23 AM   #9  
New Member
Dave in SV is offline
 
Join Date: Dec 2008
Posts: 1
Dave in SV See this member's comment history on his/her Profile page.
I want to insulate the roofline of my pole barn (steel roof). Any suggestions on how to do that? I am thionking of following the top chord of the trusses.
Quote:
Originally Posted by astrobiker View Post
There is a considerable amount of misinformation on the web about insulation of cathedral ceilings. There is a science to this that must be followed. There is no single, simple answer to this question because it depends on the climate zone you live in.

First, for the most complete answer, go to buildingscience.com and search. They give a full treatise on this topic.

The abbreviated answer is that the underside of the roof sheathing needs to be protected from moisture and condensation. However, many of the commonly accepted practices only answer part of the question or lead to unsatisfactory, partial solutions.

If you are venting under the sheathing
:
The purpose of venting is to allow a clear air flow to every cavity. In order for this to occur, you need: a) a clear passageway under the sheathing, preferably 2". 1" is too small even though it is often recommended; b) sufficient venting at soffit and ridge. Sufficient is defined as the area of the room below divided by 150 to 300 depending on the conditions. Safest is to shoot for 150. That is: room area / 150 equals square feet of venting.
So, for example, if you have a 500 square foot room, then you need approximately 3 square feet of venting area at the soffit and the roof. Many soffit and ridge vent systems are inadequate in this regard, providing vastly less area than this. See Cor-a-vent's website for details of venting. They have excellent documents describing proper venting.
Note that this precludes the "side venting" suggested by another poster unless you can figure out how to get 3 square feet of venting out the sides. Most people use those little 3" vent plugs that might have a square inch of air space, if you're lucky.

Note that this is NOT the case of "I can't do it completely, I'll do it partially". If you don't have enough area, then the air flow will be inadequate.
Also, another problem is that most cathedral ceilings have skylights. These are blocked areas that cannot be vented without cleverness.

If you are NOT venting under sheathing

Contrary to popular opinion, venting is not necessary, and can do more harm than good if not implemented properly. Remember, the key is to keep the roof sheathing from getting wet. Most moisture is carried by air movement. For example, a recessed light installed in a cathedral ceiling is roof rot ready made.
The best solution is to apply closed cell polyurethane spray foam directly to the underside of the roof sheathing. 2-3" is necessary in most climates, but see the Building Science literature for details. Closed cell polyurethane is a very effective vapor retarder when applied to these thicknesses. If moisture cannot reach the roof deck, you're in good shape (as long as the roofing above it is in good shape).
The advantage to this solution, as noted, is that internal warm humid air can't even touch the sheathing, so it will never condense. This air seals and insulated. So, if you install recessed lights in the sheetrock below, you're still protected. Every other solution fails when you have ceiling penetrations, especially if you place a vapor barrier like plastic sheeting in the ceiling. Since the vast majority of moisture movement is at penetrations. If you install plastic sheeting, the electrician will cut a big hole in it where the recessed light pokes through. Since all such fixtures leak, unless extremely carefully detailed (never done), the air will leak into the cavity. With normal insulation (fiberglass), this moisture then gets trapped in the cavity by the plastic, rotting out your roof unless you have ample air flow to carry the moisture away.

Another solution is to use dense packed cellulose. This is defined as ~3.5 pounds per cubic foot. Studies on thousands of homes (see Applegate insulation's website) have shown that fully filling the cathedral ceiling cavity minimizes air infiltration and provides a long lasting roof with good insulation. The key is that it has to be dense packed cellulose and there must be no venting into this space.

This just touches on a couple key considerations. To summarize:
If you're going to ventilate, you have to do it right
If you use fiberglass, you have to ventilate
If you use spray foam, you should not ventilate, nor should you use any other vapor barrier.
If you use dense packed cellulose, do not ventilate or use vapor barriers.
  Reply With Quote
 
     
 
 
Old Dec 19, 2008, 10:34 AM   #10  
New Member
astrobiker is offline
 
Join Date: Feb 2008
Location: New Hope, PA
Posts: 2
astrobiker See this member's comment history on his/her Profile page.
Many people spray closed cell foam directly against the underside of the metal roof or roof deck. It's not the cheapest solution but it has many advantage - it gets in all the cracks, reduces noise, provides rigidity, keeps moisture from condensing on the roof deck etc.

There are also a number of discussions about metal roofs here
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
cathedral ceilings in a ranch
(3 replies)
Attempting to install ceiling fan in older house
(6 replies)
Ceiling fan / house wiring
(1 replies)
Hanging ceiling fan from vaulted ceiling peak
(2 replies)
mice in ceiling of semi-detached house
(1 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 11:32 PM.