Old Nov 4, 2009, 10:10 AM
Jack Spratt
New Member
Jack Spratt is offline
 
Join Date: Nov 2009
Posts: 3
Jack Spratt See this member's comment history on his/her Profile page.
DCS PC1832 Programming (Night Zone)

I just had my system installed. I have a numeric keypad only. I am a programmer by trade, but not this systems. I program business systems.

I would like to program some ZONES as Night Zones. So that when I use the Interior Stay mode and press the[*][1] command I would get some additional (Nigth) zones activated.

I have a keypad outside the bedroom door and I would like to activate the basement PIR and main floor PIR, as well as a glass break.

Can someone please guide me step by step to accomplish this programming task.

Many thanks in advance.

Reply With Quote
 
     

Answers
 
 
Old Nov 4, 2009, 10:15 AM   #2  
Über Member
Stratmando is offline
 
Stratmando's Avatar
 
Join Date: May 2007
Location: Florida Keys
Posts: 6,245
Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.
Have to run, I can help in about an hour when I get Back.
Are you using All Zones, and do you have any Expanders?
  Reply With Quote
 
     
 
 
Old Nov 4, 2009, 10:30 AM   #3  
New Member
Jack Spratt is offline
 
Join Date: Nov 2009
Posts: 3
Jack Spratt See this member's comment history on his/her Profile page.
I have an expander and I'm not using all zones. Expander, you mean an additional control pannel box.

I await your assistance, thanks.
  Reply With Quote
 
     
 
 
Old Nov 4, 2009, 12:32 PM   #4  
Über Member
Stratmando is offline
 
Stratmando's Avatar
 
Join Date: May 2007
Location: Florida Keys
Posts: 6,245
Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.
I think easiest way would be might be the *71 or *72 Command.
By default *71 controls PGM Output 1(50ma max current)
The *72 Command controls Programable Output #2(300 ma max).
If you have Smokes, which are usually powered through PGM 2, to allow a Smoke Reset(remove power for 5 seconds),
then use PGM 1 to control a three pole relay to Shunt the 3 zones, if EOL's are used then EOL's will be needed at the relay as well for each zone.
One thought on Glass Breaks, if it is a 24 hour zone, and you don't have Birds, lots of Glass breaking, this way, if an Intruder is in the house during the day, A kid, wife, homeowner could throw an object through a window to trigger a Siren, when a keypad is not in reach.
  Reply With Quote
 
     
 
 
Old Nov 4, 2009, 12:47 PM   #5  
Über Member
Stratmando is offline
 
Stratmando's Avatar
 
Join Date: May 2007
Location: Florida Keys
Posts: 6,245
Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.
Altronix.com has nice Products, an RB 7 is a seven pole double throw, it draw 10 ma for each relay, since you are using 3 of them that will be 30 ma. Don't go over 50ma.
Altronix doesn't make a smaller one, and 2 DPDT relays will exceed the 50 ma.
Here's the module:
Altronix: a leading manufacturer of electronics and high technology components
  Reply With Quote
 
     
 
 
Old Nov 5, 2009, 11:13 AM   #6  
New Member
Jack Spratt is offline
 
Join Date: Nov 2009
Posts: 3
Jack Spratt See this member's comment history on his/her Profile page.
Wow, that's allot of information. I have never programmed these devices before. I need step by step instructions to implement the "Night Zone" functionality. I talked to my installer yesterday and he told me all the zones are Night Zones and I would need to bypass the ones I didn't want on when using that feature. If so,[*][1] should enable all my sensors.

Can someone help me step by step, to read and understand, or better reference material for learning the programming code?
  Reply With Quote
 
     
 
 
Old Nov 5, 2009, 01:59 PM   #7  
Über Member
Stratmando is offline
 
Stratmando's Avatar
 
Join Date: May 2007
Location: Florida Keys
Posts: 6,245
Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.
The 1832 replaces the older PC5010, slight differences/advances with the 1832, I see they have Group Bypassing and is not in the Installers/Programming, which is what I have, I give the Users manual to the customer. I have to go to DSC's site and download the Owners/Operating Manual, you should have that. Read on Group Bypassing, Do you have Smokes, Because if you don't, You could wake in the middle of the night, press reset, and it will toggle those zones in and out, it is 1 button, Bypassing 3 zones usually takes a couple of steps.
I am curious of other answers as well.
  Reply With Quote
 
     
 
 
Old Nov 6, 2009, 06:26 PM   #8  
Über Member
Stratmando is offline
 
Stratmando's Avatar
 
Join Date: May 2007
Location: Florida Keys
Posts: 6,245
Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.Stratmando See this member's comment history on his/her Profile page.
Do you have Owners Manual? If you are satisfied on Group Bypassing method, I Don't want to write out other method needlessly.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
Programming DSC PC1832 alarm
(1 replies)
programming manual dsc pc1832
(2 replies)
programming a DSC PC1832
(2 replies)
2 zone oil heat, 2nd zone runs 1st zone
(1 replies)
programming 3 zone thermostat
(3 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 02:27 PM.