Ask Experts Questions for FREE Help !
Ask
    rector's Avatar
    rector Posts: 1, Reputation: 1
    New Member
     
    #1

    Mar 22, 2010, 05:11 PM
    Wiring a four wire air condenser fan motor
    I am replacing an old GE motor, fan blade, and capacitor, three wires. The new motor is a AO Smith. With four wires. Tan, tan-white, yellow, and black. I am going to wire up as a three wire connection, as follows, tan-white to the capacitor, (two prong) then, the yellow to the capacitor, ( four prong), then the black, to the contactor.

    Does this appear to be right? Also, I forgot to check fan rotation, prior to removal. The motor is seen from the top of our unit, fan blade is under that. Should the fan rotation be CW or CCW. I understand that the fan should be pulling air up through the sides of the unit and air should be coming up from the unit, a piece of thread should be blowing upward. Please make a comment...
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #2

    Mar 22, 2010, 08:51 PM
    There's a lable pasted on the side of the motor,, directions for wiring, follow them closely,and yes the air should be blowing up through the top, not being there this is about all that can be said, as for direction, clockwise or counter-clockwise,a lot if motors can be changed by switching a couple wires
    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #3

    Mar 23, 2010, 05:09 AM

    If you don't have a thread, I think a rope would work. Swapping 2 wires as mentioned to reverse direction is usual, Air should be blowing out the top.
    Do you have a number for the motor?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

How do I wire up my new AC condenser fan motor? [ 7 Answers ]

My new AC condenser fan motor has an extra wire. What do I do with it? AC is a 1996 SEER 12 Rheem. New motor is an A.O. Smith 1/8 HP 208 RPM 208-230 volt. Old motor has 3 wires, black, brown, and orange. New motor has 4. Black, brown, orange, and brown with a white stripe. Does anybody...

How do I wire a new condenser fan motor [ 5 Answers ]

I have a Trane unit with GE condenser fan motor number 5kcp39fg. New condennser fan motor is A.O. Smith number F48k92A01. My question is on the old fan motor there were only 3 wires two for cap and looks like 1 for motor line and the new motor has a brown and brown/white for cap a black for line...

Emerson motor condenser wiring replacing 3 wire motor with 5 wire. [ 5 Answers ]

Any recommendations? New motor apparently is capable of running in either direction by switching brown and purple wires going to the capacitor. Looks like then either the remaining brown or purple is spliced to or hooked up to the same terminal as the yellow. Thanks.

How do I wire up a new condenser fan motor [ 5 Answers ]

The old condenser fan motor (EMERSON model # is K48HXFCN-3727,HP-1/8,v 208-230,rpm 1075with 3mfd 370vac dual capacitor) is making a noise.When I got a new one (EMERSON model#is K48HXTMG-4003 HP-1/8,v208-230,rpm1075 come with 5.0mfd 370vac capacitor). I am confused, I need help trying to do the...

Where to land the yellow wire off condenser fan motor? [ 1 Answers ]