    White-Rodgers Thermostat & Payne Furnace - wiring - blown fuses
    Over the summer my mechanical thermostat broke and I replaced it with a White-Rogers 1F78 (digital). I thought this was going to be easy, but in a long process of trial and error the furnace fuse blew several times. Finally we got the heater to work, but when we'd turn on the A/C, the fuse would blow. Eventually we got the A/C working, but then turning on the heater would blow the fuse... very frustrating... we stuck with the A/C since that's what we needed at the time.

    Well it's winter now, and we really need the Heater instead. Having both the heater and A/C wired correctly would be great :) I can't figure out where I'm going wrong with the wiring. I've checked the manuals for both the heater and the A/C. At this point, I can't even be sure if it's the wiring on the furnace end, the thermostat end, or both, that's screwed up. Here are some pictures of both the furnace end wiring and the thermostat end wiring. Any help?

    Thermostat Manual
    Installation Manual Part 1
    Installation Manual Part 2

    I know the PCB labels are tough to read. So I've tried to clarify them where needed with purple text.

    FURNACE END WIRING
    On the picture of the Furnace end, the white and red wires at the top connect to a pump for removing condensation (I believe).

    The purple 3-amp fuse to the right is the one I've blown many many times.



    THERMOSTAT END WIRING
    Notice how RH and RC are jumpered together by the manufacturer. I don't know why that is.

    KC13's Avatar
    KC13 Posts: 2,556, Reputation: 99
    Ultra Member
     
    #2

    Dec 22, 2008, 08:54 AM

    Rc-Rh jumper is needed for single transformer systems, can be removed for 2 transformer systems. Confirm which you have, but based on what I see it looks like 1. The connections look right with one exception: remove the blue wire from the "com" terminal at the furnace and the "B" terminal at the thermostat. This circuit is causing the fuse to blow.
    justincaseme's Avatar
    justincaseme Posts: 62, Reputation: 1
    Junior Member
     
    #3

    Dec 22, 2008, 05:21 PM
    Quote Originally Posted by KC13 View Post
    Rc-Rh jumper is needed for single transformer systems, can be removed for 2 transformer systems. Confirm which you have, but based on what I see it looks like 1. The connections look right with one exception: remove the blue wire from the "com" terminal at the furnace and the "B" terminal at the thermostat. This circuit is causing the fuse to blow.

    It worked! Thank-you! BTW, if you happen to check this again, maybe you can answer one other quick questions about the setup.

    * Are the red and white wires to the condensation pump hooked up correctly? My understanding is that a float ball inside the pump-tank rises with the water level and trips the pump as needed. What are these red and white wires doing then? Are they even needed?

    Thanks
    KC13's Avatar
    KC13 Posts: 2,556, Reputation: 99
    Ultra Member
     
    #4

    Dec 22, 2008, 05:38 PM

    Post a pic. It is probably an auxiliary float switch that can be used to disable the system or activate an alarm if the pump malfunctions and the reservoir is over-filling. I encounter a lot of these that are not hooked up. Pity...

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Changed over from White Rodgers Thermostat to Honeywell thermostat [ 3 Answers ]

I have a White Rodgers 2 stage heat/1 cool model 1F58-58 heat pump thermostat that I have changed over to a Honeywell programmable thermostat model RTH7400. Did all the correct wiring as stated in the books but when set to cool, the heater kicks on instead of the central air conditioning. What...

Changing over from White Rodgers Thermostat to Honeywell thermostat [ 3 Answers ]

I have a White Rodgers 2 stage heat/1 cool model 1F58-58 heat pump thermostat that I want to change over to a Honeywell programmable thermostat model RTH7400. I need help in trying to figure out the wiring part of this whole thing. Can someone out there please help. I would certainly appreciate...

Need Wiring help for a White-Rodgers Thermostat [ 2 Answers ]

I have 2 wire (red & White) heat only system. It is steam heat run by gas. Currently I have Honeywell thermostat which uses 3 AA batteries. Thermostat has R, RC, O, W, Y, G terminals. R and RC terminals are connected by a jumper cable. I have Red wire connected to terminal R and white wire...

Wiring info - older Weathertron thermostat with White Rodgers [ 1 Answers ]

Looking for wiring instructions in replacing older bulb type Weathertron thermostat model 3AAT80A101 with wiring as follow: G - black Y - white X2 - white looped with - W - terminal B - black O - white R - red Unidentified contact - red

White-Rodgers to new Hunter Thermostat (Wiring Help Please) [ 4 Answers ]

Hello, I have a new home, built in 2003, with Central Heat and Air. It's all run off electricity and is using a Lennox Model CB29M-41-1P heat pump. The WHITE ROGERS DIGITAL HEAT PUMP THERMOSTAT 1F89-211 used the following wires: White Red Brown Orange Yellow


View more questions Search