Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Jul 5, 2007, 06:17 PM
Jeff Biskup
New Member
Jeff Biskup is offline
 
Join Date: Jul 2007
Posts: 5
Jeff Biskup See this member's comment history on his/her Profile page.
fan direction reversed by power surge

I have a condenser fan on an existing Janitrol ckj36-1b condensing unit. The fan seems to have reversed direction, most likely from a power surge. There was a strong electrical storm last night and the fan is now blowing back down thru the condenser, rather than drawing the air thru the condenser.

The adjacent condensing unit is running fine.

Has anyone experienced this problem? Any recommendations for solution?

Reply With Quote
 
     

Answers
 
 
Old Jul 5, 2007, 06:34 PM   #2  
letmetellu
Ultra Member
letmetellu is offline
 
Join Date: Dec 2005
Location: Texas
Posts: 1,787
letmetellu See this member's comment history on his/her Profile page.letmetellu See this member's comment history on his/her Profile page.
It is possible that you have a blown capacitor and the motor started in the wrong direction because of it. That is one thing. Does the motor seem to be running at full speed? And I will ask, knowing that you probably have tried several times to see if it starts in the same direction each time.? There is a trick you can try to see if it might be the capacitor. Use a small stick and turn the fan in the right direction with the stick at the same instant start the condensing unit. Let me know what you find out.

Comments on this post
esquire1 agrees: Good way to check
  Reply With Quote
 
     
 
 
Old Jul 5, 2007, 07:43 PM   #3  
Jeff Biskup
New Member
Jeff Biskup is offline
 
Join Date: Jul 2007
Posts: 5
Jeff Biskup See this member's comment history on his/her Profile page.
The motor runs full speed and starts consistently the wrong direction. I tried pre-spinning the blade, but it pulls back the wrong direction.

Also checked the motor rotation, and it is runner the opposite direction of what is written on the motor.
  Reply With Quote
 
     
 
 
Old Jul 5, 2007, 07:51 PM   #4  
hvac1000
Heating & Air Conditioning Expert
hvac1000 is offline
 
hvac1000's Avatar
 
Join Date: Aug 2005
Location: Ohio
Posts: 5,001
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
Some motors have a plug and some you have to change the wiring but usually you can change the rotation of the motor.

One of my old tricks with motors that did not have the capability to change directions was to take the motor apart and change the shaft to the other end. This way the magnet and armature are reversed and it will spin in the opposite direction. I do not recommend doing this if you do not know what you are doing.

Comments on this post
acetc disagrees: Since when can a storm reverse a plug or change wires? only split phase motors can the reversed by changing the armature. LOL
  Reply With Quote
 
     
 
 
Old Jul 5, 2007, 08:04 PM   #5  
Jeff Biskup
New Member
Jeff Biskup is offline
 
Join Date: Jul 2007
Posts: 5
Jeff Biskup See this member's comment history on his/her Profile page.
Have you ever seen a motor change running direction like this?

I don't have the equipment to test the capacitor. But I suppose I should pull it and have it tested, and be prepared to by a replacement motor if the capacitor is good.
  Reply With Quote
 
     
 
 
Old Jul 5, 2007, 08:24 PM   #6  
Jeff Biskup
New Member
Jeff Biskup is offline
 
Join Date: Jul 2007
Posts: 5
Jeff Biskup See this member's comment history on his/her Profile page.
HVAC1000,

"Some motors have a plug." What does the plug look like? Does it have a cover that pops or twists off? Do you pull it and rotate it to switch polarity.

By the way. This IS a single phase application.

Thanks to all for your help.

Jeff
  Reply With Quote
 
     
 
 
Old Jul 5, 2007, 08:24 PM   #7  
hvac1000
Heating & Air Conditioning Expert
hvac1000 is offline
 
hvac1000's Avatar
 
Join Date: Aug 2005
Location: Ohio
Posts: 5,001
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
Not without some kind of a phase change. Might try a capacitor but do not old your breath.
  Reply With Quote
 
     
 
 
Old Jul 5, 2007, 08:25 PM   #8  
hvac1000
Heating & Air Conditioning Expert
hvac1000 is offline
 
hvac1000's Avatar
 
Join Date: Aug 2005
Location: Ohio
Posts: 5,001
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
The plug is just a two sided piece pluged in. You unplug and rotate 180 degrees and plug back in.
  Reply With Quote
 
     
 
 
Old Jul 6, 2007, 06:18 PM   #9  
letmetellu
Ultra Member
letmetellu is offline
 
Join Date: Dec 2005
Location: Texas
Posts: 1,787
letmetellu See this member's comment history on his/her Profile page.letmetellu See this member's comment history on his/her Profile page.
Some motors have a polarity changing ability that has four short wires coming out of the motor and two each of these wires are connected to change rotation you switch the wires . This is not the right colors but I am just using this to give you and idea. You may have a purple connected to an orange and a yellow connected to a pink. To change connect the pink to the purple and the orange to the yellow. Like I said this is not the right colors for you to use just an idea of how it works. The colors you should use is or may be printed on the side of the motor.
  Reply With Quote
 
     
 
 
Old Jul 6, 2007, 06:24 PM   #10  
letmetellu
Ultra Member
letmetellu is offline
 
Join Date: Dec 2005
Location: Texas
Posts: 1,787
letmetellu See this member's comment history on his/her Profile page.letmetellu See this member's comment history on his/her Profile page.
I meant to mention that I have never seen a single phase motor change directions like you have described unless the Run, Start and Common connectors had been connected wrong, and if this did happen your motor would not run for very long without over heating and probably burning out.
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
power surge in kitchen ukgarrison Electrical & Lighting 3 Feb 6, 2007 07:15 AM
Ceiling Fan Direction esquire1 Heating & Air Conditioning 2 Oct 29, 2006 03:30 PM
How do I reverse ceiling fan direction? Hogue6 Electrical & Lighting 2 Sep 4, 2005 11:33 PM
Ceiling fan direction: Summer vs. Winter Ferdball Electrical & Lighting 1 Aug 22, 2005 02:11 AM
TV power surge Hunter1 Electrical & Lighting 2 Feb 27, 2005 06:17 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 04:19 AM.