    What do five blinking red lights mean on a xe80 trane furnace
    I have a XE80 furnace (installed sept.1995) the light blinks five times. The thermostat is off but a fan motor comes on that can be heard at the return vent.
    kevinl123's Avatar
    kevinl123 Posts: 2, Reputation: 1
    New Member
     
    #2

    Sep 24, 2012, 08:21 PM
    On my unit this is a flame rollout sensor error. Check your rollout sensors there will be a couple in the burner area they are small and round and have two wires going to them, some are resetable and have a small red button. Check for continuity through the sensor with a multi-meter. If they are open push the red button or replace them if they are not resetable. If you trace the wire you will see it is daisy-chained to make the cisrcuit through all the sensors, follow it as there may be other sensors depending on your configuration. You should be able to trace it from the control board in/out of all the sensors and returning to the control board. There may also be one in the fan blower box that will require you to remove the control board and flue vent pipe in order to pull the panel accessing the fan blower.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Trane xe80 internal control board failure, red light on steady [ 1 Answers ]

Trane xe80 internal control board failure, red light on steady

Trane xe80 internal control board failure, red light on steady [ 0 Answers ]

My furnace runs for a while then the flame goes out but the blower keeps running. Control board has solid red light that means internal control board failure (replace)I turn off the power to the unit and then turn back on, it runs for a while then repeats. Seems to get worse the colder it is outside

I have a 3yr old Trane XR90... I'm getting 4 blinking lights... [ 0 Answers ]

I need help... what do I do??

TRANE XE80. Problem Code: 1 long and 4 short blinking lights [ 0 Answers ]

One morning about a month ago, my furnace wouldn't start. The repairman came and replaced the "inducer draft motor and blower assembly". Not cheap! At that time I didn't know enough to record the blinking light code, but looking back I think it was blinking 3 times. Now, a month later, at 6 am...

XE80 Trane Furnace-no ignition of gas [ 1 Answers ]

I have furnace that calls for heat from thermostat, ignition coil(stick) lights up, sometimes I get gas ignition and sometimes not, then the gas shuts down. The blower motor continues to run. I cleaned the temperature sensing rod. The control board lights up with the message "Internal control...