#1  
Old Oct 13, 2006, 06:21 AM
cbella
New Member
cbella is offline
 
Join Date: Oct 2006
Posts: 4
cbella See this member's comment history on his/her Profile page.
Whalen Heat Pump - no heat!

Hi,

I live in a condo and have a Whalen Heat Pump. I changed the thermostat to a Noma digital programmable model (model # 52-255808) in the summer time. The A/C works well and the fan works well, but I did not test for heat as it was summer when I installed it.

Well, now that the weather is getting cold, I am not getting any heat! I am wondering maybe I did not wire the thermostat properly.

There are 4 wires: Red, Green, Yellow and Blue.

So, I connected them as follows:

Red - RH (RC and RH has a jumper on it)
Green - G (it says Fan Relay on the diagram)
Yellow - Y (it says Cooling Relay on the diagram)
Blue - W (it says Heating Relay on the diagram)

I shorted the Red and Green wire and the fan does come on. I did the same for the Red and Yellow wire and the air comes on. But when I shorted Red and Blue I hear a click but nothing else happens.

Please help. It's freezing in my unit.

Thanks in advance!

Reply With Quote
 
     

Answers
 
 
Old Oct 13, 2006, 11:52 AM   #2  
cbella
New Member
cbella is offline
 
Join Date: Oct 2006
Posts: 4
cbella See this member's comment history on his/her Profile page.
Can someone confirm that the Blue wire should be connected to the 'W' terminal?

I'm thinking maybe the Blue wire should not go to the 'W' terminal.

Thanks!
  Reply With Quote
 
     
 
 
Old Oct 13, 2006, 12:00 PM   #3  
tkrussell
Electrical & Lighting Expert
tkrussell is offline
 
Join Date: Jan 2005
Posts: 4,555
tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.tkrussell See this member's comment history on his/her Profile page.
Process of elimination means the blue is for the heat, and should get connected to the W terminal. When you shorted the blue to red, and something clicked, it may take a few minutes for your heat to actually start.

Let it run a while, if the heat stll does not start, then there is a problem with the heating unit.
  Reply With Quote
 
     
 
 
Old Oct 13, 2006, 06:45 PM   #4  
Kender
Junior Member
Kender is offline
 
Join Date: Sep 2006
Location: Biloxi, MS
Posts: 62
Kender See this member's comment history on his/her Profile page.
Are you sure that it is a heat pump? if so try connecting all four wires together. R-power, G to turn on the fan, Y to turn on the compressor, and B for the revercing valve to reverce the flow of freon. If that works then that t-stat will not work on heat pumps.

if it is not a heat pump then your wiring is correct. try turning the fan to ON then turning on the heat. some systems will not turn on the heat with out the fan being "ON" like Trane air handlers not sure about whalen. if that works than there should be a gas elect switch that needs to be changed on the t-stat.
  Reply With Quote
 
     
 
 
Old Oct 14, 2006, 09:06 AM   #5  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Quote:
Originally Posted by cbella
Hi,

I live in a condo and have a Whalen Heat Pump. I changed the thermostat to a Noma digital programmable model (model # 52-255808) in the summer time. The A/C works well and the fan works well, but I did not test for heat as it was summer when I installed it.

Well, now that the weather is getting cold, I am not getting any heat! I am wondering maybe I did not wire the thermostat properly.

There are 4 wires: Red, Green, Yellow and Blue.

So, I connected them as follows:

Red - RH (RC and RH has a jumper on it)
Green - G (it says Fan Relay on the diagram)
Yellow - Y (it says Cooling Relay on the diagram)
Blue - W (it says Heating Relay on the diagram)

I shorted the Red and Green wire and the fan does come on. I did the same for the Red and Yellow wire and the air comes on. But when I shorted Red and Blue I hear a click but nothing else happens.

Please help. It's freezing in my unit.

Thanks in advance!
I've never seen a heatpump that operates on just 4 wires. But after 20 years of service work I've never heard of a Whalen either. or a Nora. Look in the installer set-up book for the thermostat. You will need to get into the program mode and tell it that it is a heat pump, and weather the reversing valve is actuated on cooling or heat. Do you live in a very warm climate where an emergency heat source is unnecessary?
  Reply With Quote
 
     
 
 
Old Oct 15, 2006, 07:29 AM   #6  
cbella
New Member
cbella is offline
 
Join Date: Oct 2006
Posts: 4
cbella See this member's comment history on his/her Profile page.
Thanks to everyone who responded. The issue is now resolved and here's what we did to resolve it:

Blue wire connects to 'B' terminal
Yellow wire connects to 'Y' terminal
Green wire connects to 'G' terminal
Red wire connects to 'RH' terminal

By default, there is a jumper on RH and RC, leave that as is.
There is also a jumper on HG, leave that as is.

To add:
Get a very short wire to create a jumper on 'Y' and 'W' terminal.

Turn thermostat on to Heat and it works!

Comments on this post
labman agrees: Letting us know what works is the best way of helping others and encouraging people to help.
  Reply With Quote
 
     
 
 
Old Oct 15, 2006, 07:38 AM   #7  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Glad to hear you got it figured out. The blue wire must be for the reversing valve. Did you check and see that the A/C also works correctly?
  Reply With Quote
 
     
 
 
Old Oct 18, 2006, 07:19 AM   #8  
cbella
New Member
cbella is offline
 
Join Date: Oct 2006
Posts: 4
cbella See this member's comment history on his/her Profile page.
Yes, I've confirmed that a/c works as well!

Thanks!
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Heat Pump - Payne peterblair Heating & Air Conditioning 0 Aug 6, 2006 07:37 AM
Heat pump question mgfarmer Heating & Air Conditioning 1 Jul 6, 2006 04:40 PM
heat pump installation paulb073 Pools - Spas & Saunas 0 May 28, 2006 11:01 PM
Heat Pump?? extreme42583 Heating & Air Conditioning 2 Feb 19, 2006 06:30 AM
Heat Pump GoneFishin Heating & Air Conditioning 7 Oct 5, 2005 10:59 AM