Asked Jun 8, 2008, 12:27 PM — 3 Answers
Just this past fall I had a new furnace installed. I recently just started using the AC and after a couple of days noticed that there is water leaking at the top of the furnace. I have never had any problems with leaking before the new furnace was installed. I have verified that the drain line (from the drip pan) to the condensate pump is NOT clogged and the pump is working. There is some rust on the drain pan but does not look like it is rusted through. I saw another post that speaks about the drain pan being level.
I am being told that I should replace the coil/drain section and probably my ac unit also because of the make and age.

Just wanted some thoughts as to whether the new furnace install is most likely the reason for the leaking and if I should replace my ac unit.

Thanks
FE

3 Answers
hvac1000's Avatar
hvac1000 Posts: 14,539, Reputation: 2381
Heating & Air Conditioning Expert
 
#2

Jun 8, 2008, 03:24 PM


Probably the drain pan is rusted. A qualified installer can patch or change the drain pan. If you got the $$ go with a new unit. You will save big $$$ on your energy bill.
Helpful
fa5teddie's Avatar
fa5teddie Posts: 2, Reputation: 1
New Member
 
#3

Jun 8, 2008, 06:10 PM
Just verified, opened the side panel and stuck my head in and with a bright light I can see some rusted through holes in the drain pan.
You are right, because the coil/drain section isn't going to be available after this year, I guess because of the age, I would have to replace both the ac unit and the coil/drain section(again) if anything happened to the ac unit. So in the long run better to replace both now and be done with it. Also refrigerant is low.

Thanks for the quick response and advice.
Helpful
hvac1000's Avatar
hvac1000 Posts: 14,539, Reputation: 2381
Heating & Air Conditioning Expert
 
#4

Jun 8, 2008, 06:45 PM


Glad you figured it out.
Helpful

Not your question? Ask your question View similar questions

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search

Add your answer here.

Remove Text Formatting

Undo
Redo
 
Decrease Size
Increase Size
Bold
Italic
Underline
Align Left
Align Center
Align Right
Ordered List
Unordered List
Decrease Indent
Increase Indent
Insert Email Link
Wrap [QUOTE] tags around selected text
Wrap [CODE] tags around selected text
Wrap [HTML] tags around selected text
Wrap [PHP] tags around selected text
Wrap [YOUTUBE] tags around selected text
Notification Type:



Check out some similar questions!

Water leaking from furnace [ 11 Answers ]

I have a York Affinity furnace with a Honeywell humidifier. It is three years old and this season I have noticed that there is watwer leaking down from the top and leaking in the midle and pooling at the bottom. I had reduced the air flow on the by pass and reduced the water flow by adjusting the...

Water leaking from furnace [ 4 Answers ]

I have water leaking out from under my furnace. It has gone under the wall and into my daughters bedroom and soaked her carpet. Please advise

( AC) Furnace is leaking water in the pan . [ 3 Answers ]

Hello, My (AC) unit Furnace is leaking water in the pan when I run AC unit when the Florida weather is hot outside. Almost on monthly basis I am vaccuming out water accumulated in the pipe that is connected to the furnace to let out water. Now, the pan is rusted and leaking and water is...

Why is my furnace leaking water? [ 2 Answers ]

Why is my furnace leaking water?

Water leaking from gas furnace [ 2 Answers ]

I found water, or liquid leaking from my gas furnace. What can this be? Recently we had a repair man come, he replaced an igniotor. The furnace is 7 years old. HELP!


View more Heating & Air Conditioning questions Search