Hello,

I have a two-zone forced air system using an oil furnace. A week or so ago, I lost the ability to start the furnace from the downstairs thermostat, which was a standard round Honeywell electro-mechanical. I could start and stop the fan by setting the control to "On" rather than "Auto", but with the other switch set to "Heat" the burner just wouldn't come on.

To diagnose, I shut off the furnace breaker and fan switch and tied the R and W wires together. When I turned the breaker back on, the furnace and fan both started, which I assumed meant the thermostat was bad.

I replaced both thermostats with programmables but continue to have the problem. Once again, after turning the breaker back on, the furnace and fan started, but after 10-15 minutes (not long enough to reach the set to temp) they went off, never to start again from the new downstairs thermostat.
The upstairs zone works fine with the new programmable.

I noticed the downstairs vents appear to be open because running the heat from upstairs also generates hot air downstairs. I'm not familiar with how the vent switching works and don't know if the downstairs was just left open from the initial time it ran after restoring power.

Both thermostats have R, RH, Y, G, and W wires.

Any help would be appreciated.

Thanks,
Frank

Reply With Quote
 
     

Answers
 
 
Old Feb 28, 2006, 04:57 AM   #2  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
Are the vents electrically operated? If there are more than 2 wires running to them, the system may use a switch at the vent to start the heat. Of course that doesn't explain the system running with the red and white connected.

Does the thermostat show the temperature as being below the set point after it shuts off? Do you have the R and RH jumpered at both thermostats?
  Reply With Quote
 
     
 
 
Old Feb 28, 2006, 08:06 AM   #3  
New Member
frankp_93 is offline
 
Join Date: Feb 2006
Posts: 2
frankp_93 See this member's comment history on his/her Profile page.
Labman,

Thanks for the quick response. I removed the R - RH (actually R - RC) jumper from both thermostats as per the instruction book and wired the old R to the new RC and the old RH to the new R.

I assume there's an electric switch for the vents but don't know for sure. There are two boxes above the furnace with slider switches indicating "Auto" and "Man Open", They're both set to "Auto" and I haven't touched them. I don't think the problem is with the vents per se, because I can run the fan from the downstairs thermostat and can feel (unheated) air coming through the downstairs vents.

Thanks,
Frank
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes
Ask your question or search...



Similar Threads
cd-rom unable to read
(3 replies)
Unable to start up the computer
(2 replies)
Furnace blower can not auto start
(23 replies)
Furnace won't start after storm
(1 replies)
unable yo delete
(4 replies)

Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page
Search this Thread

Advanced Search

Bookmarks





Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 12:27 AM.