Ask Experts Questions for FREE Help !
Ask
    Jdubb4981's Avatar
    Jdubb4981 Posts: 1, Reputation: 1
    New Member
     
    #1

    Apr 18, 2014, 10:32 AM
    Trouble wiring a Goodman 2 ton package unit outside cooling fan.
    Ive had to go behind someone's work. Im trying to figure out how to wire a cooling fan. Coming from the unit is 3 wires. Two of the wires one brown the other purple are coming from the capacitor. The 3rd is black coming from the contactor. Coming from the fan is a black, white, brown and brown and white. Also the old fan was disconnected while the power was on. Sometime from the disconnection t my arrival the wires have made contact and the board has 3 burnt connections. Ive already replaced the capacitor because it was swelled. The contactor is clean and emitting the proper voltage. Before I replace the board Im going to check the compressor for continuity. But the fan is the biggest problem for me right now. Any advice is appreciated. Thanks

Check out some similar questions!

Condenser Fan Motor Wiring for Goodman AC Heat Pump 3 Ton [ 5 Answers ]

Condenser Fan Motor Wiring for Goodman 3 Ton -------------------------------------------------------------------------------- Hello Everyone, I have a GOODMAN A/C Heat Pump Model# CPLE 36-1 installed 3 years ago. Last week I turned the unit on, the compressor hums (not run)about 3-5...

New York 5 ton package unit flashing code #8 (flame loss) sometimes only [ 0 Answers ]

I had my ex-brother in law who works for a York dealer convert my old furnace/swamp cooler over. He did a terrible job doing the install so we had a falling out because of it. He also lost the receipt for the unit so I don't know how to get the warranty work done on it by anyone else. I don't want...

Goodman 2 1/2 ton unit [ 8 Answers ]

My Landlady just bought a new goodman outside unit. It worked for about a week then cut off. The Installer said it could have been anything and needs a new compressor. She has spent about as much as she did for the upstairs unit (a payne) that works fine after 12 yrs of operation. What's the deal...

I have a Goodman heat pump, I think about 5 ton unit. The fan keeps stopping [ 2 Answers ]

The fan will stop after aprox 5 - 10 minutes. The motor was replaced, same issue. Then the tech bypassed the defrost relay, same issue. Then he wired straight to the contactor with same issue.


View more questions Search
 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.