Home > Home & Garden > Heating & Air Conditioning   »   thermostat wiring-- Where does the blue wire go? its HOT out!

 
Thread Tools Search this Thread Display Modes
Question
 
 
Old Jul 28, 2009, 07:27 PM
rutterback
New Member
rutterback is offline
 
Join Date: Jul 2009
Posts: 6
rutterback See this member's comment history on his/her Profile page.
thermostat wiring-- Where does the blue wire go? its HOT out!

i bought a Honeywell rth221b thermostat. I was smart enough NOT to mark the wires when i took off the old one. the wires that come out of the wall are red, green, white, and blue. The thermostat looks like this-

Y-o o-Rh
G-o o-Rc
o-W

Im assuming green to G, red to Rh (Rh and Rc have a jumper between) and white to W. Where in the world does blue go??? my heat worked but not my central air. Im assuming the A/C is the blue wire?

Like a typical guy, i threw away the instructions months ago and never checked to see if the AC worked.... Smart... I know.

Thank you in advance for your help and tips.

Reply With Quote
 
     

Answers
 
 
Old Jul 29, 2009, 07:20 PM   #11  
Home Repair & Remodeling Expert
ballengerb1 is offline
 
ballengerb1's Avatar
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 15,410
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
move the red off the yellow leaving the blue still connected to yellow. Move red to the empty G on the right.

Comments on this post
siberianair disagrees: this will make it so there would be no signal to the condensor unit!
  Reply With Quote
 
     
 
 
Old Jul 29, 2009, 09:34 PM   #12  
Engineering & Electronics Expert
KeepItSimpleStupid is online now
 
KeepItSimpleStupid's Avatar
 
Join Date: Aug 2007
Posts: 9,335
KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.
I think we need to start completely over. This looks way to simple and it should be working. Hah.

I propose - disconnect the thermostat.

We are going to "play thermostat". So before trying things disconnect power. Can I assume that you don't have a voltmeter? Leave the wires attached because they are disconnected at the other end. Just add the jumpers.

Jump R to Y and Gc at the furnace. Turn on furnace. Outside unit and fan should come on. Might have to wait 2-5 minutes. Fan will come on immediately.

Turn off power. Remove these jumpers.

Jump R to W. Turn on power. Furnace should comeon and a short time later, the furnace fan should come on.

Turn off furnace. Remove jumpers.

That checks out the furnace.

DO the tests and report back.
  Reply With Quote
 
     
 
 
Old Jul 30, 2009, 03:55 AM   #13  
Full Member
siberianair is offline
 
siberianair's Avatar
 
Join Date: Jun 2009
Posts: 361
siberianair See this member's comment history on his/her Profile page.
check the fuse near your curcuit board or maybe you blew the transformer.
you did turn the power off before playing with wires on tstat didnt you?
  Reply With Quote
 
     
 
 
Old Aug 12, 2009, 12:58 PM   #14  
New Member
rutterback is offline
 
Join Date: Jul 2009
Posts: 6
rutterback See this member's comment history on his/her Profile page.
nothing is working!! please help!!! its 95 outside!!
  Reply With Quote
 
     
 
 
Old Aug 12, 2009, 01:04 PM   #15  
New Member
rutterback is offline
 
Join Date: Jul 2009
Posts: 6
rutterback See this member's comment history on his/her Profile page.
I never shut the power off like an idiot. i dont know if there is a voltmeter either? im going to try what KISS said... ill report back.. thank you
  Reply With Quote
 
     
 
 
Old Aug 12, 2009, 01:40 PM   #16  
Home Repair & Remodeling Expert
ballengerb1 is offline
 
ballengerb1's Avatar
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 15,410
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
I never did understand siberairs comment and reddie to me. He said I was wrong but never explained further. I have not seen a board on the furnace with 2 wires going to it. The blue/yellow sends the signal, the second red should be jumpered at the stat.
  Reply With Quote
 
     
 
 
Old Aug 13, 2009, 05:09 PM   #17  
Home Repair & Remodeling Expert
ballengerb1 is offline
 
ballengerb1's Avatar
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 15,410
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
This may amuse you but I see that Siberianair has been blocked out as a troll. Maybe skip his suggestions for now.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
Yikes! Does the blue thermostat wire go to the C terminal?
(11 replies)
Is thermostat blue wire needed?
(5 replies)
wiring new thermostat with B wire, also g,and w
(1 replies)
4 wire thermostat wiring
(5 replies)
wiring a 2 wire thermostat to a 4 wire system
(1 replies)