    Thermostat wire location
    Sheetrock was put up on both sides of a wall where our thermostat wires were located.
    Is there anyway that we can locate the end of this wire without cutting into the sheetrock at various places? The wire is curled up in the wall where the thermostat was to be located.
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #2

    Nov 14, 2006, 10:42 AM
    Can you localize it to one wall cavity by seeing where it goes up through the floor? If so, I would cut a hole about 4' up the wall just small enough to hide with the thermostat you intend to install. Fish around inside with a coat hanger wire or something, and maybe you will be lucky enough to snag it. If not, try a mirror and a flashlight.

    You could also try top locate it with a stud detector or with the power on, a voltage detector*. Once you know where to fish, it may work better. Either may help if you don't know which wall cavity.

    *To do simple checks like this you do need some tools. A test light, a meter, or a voltage detector might be the best place to start with. I came across the niftiest gadget for trouble shooting, a voltage detector. They work through the insulation of wires. There are several brands. I have a GB Instruments GVD-505A, less than $15 at Home Depot. Touch it to a hot wire, and the end glows red. Find the doodad that lights it on one side, and not the other, and you have the culprit. You do not have to open up housings and expose electrical contacts. You are looking at where your hand is, not where the meter is. Most people are capable of doing repairs and will get it going and not get hurt if they use a little sense. The voltage detector makes it even easier.
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #3

    Nov 14, 2006, 04:39 PM
    Apply 24 volts to any one of the wires at the furnace and use a tick tracer, about 30 dollars at Lowe's. But it will show you all live wires, 120 and low voltage.
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #4

    Nov 14, 2006, 04:40 PM
    Quote Originally Posted by labman
    Can you localize it to one wall cavity by seeing where it goes up through the floor? If so, I would cut a hole about 4' up the wall just small enough to hide with the thermostat you intend to install. Fish around inside with a coat hanger wire or something, and maybe you will be lucky enough to snag it. If not, try a mirror and a flashlight.

    You could also try top locate it with a stud detector or with the power on, a voltage detector*. Once you know where to fish, it may work better. Either may help if you don't know which wall cavity.

    *To do simple checks like this you do need some tools. A test light, a meter, or a voltage detector might be the best place to start with. I came across the niftiest gadget for trouble shooting, a voltage detector. They work through the insulation of wires. There are several brands. I have a GB Instruments GVD-505A, less than $15 at Home Depot. Touch it to a hot wire, and the end glows red. Find the doodad that lights it on one side, and not the other, and you have the culprit. You do not have to open up housings and expose electrical contacts. You are looking at where your hand is, not where the meter is. Most people are capable of doing repairs and will get it going and not get hurt if they use a little sense. The voltage detector makes it even easier.
    Yes, I also posted to this, I like the better tracer with a sensitivity adjustment. Makes low voltage wires easier to find.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Furnace thermostat needs 24 v wire [ 6 Answers ]

My new White Rogers programmable furnace stat says it needs 24 v dc to run it. I installed it and am using the 2 AA batteries to power it, but I have 4 wires coming in now. I have A/C. The stat is running OK now but if I take the batteries out the display goes dead. I don't know how to run 24 v...

6 wire AC/Heater to 5 Wire thermostat [ 4 Answers ]

Hi, I have a Coleman BRCS0301BB AC and a gas based heting unit. I see 6 wires coming up to the thermosat - Red Blue White Yellow Green Brown

3 wire thermostat [ 3 Answers ]

I am trying replace my old honeywell 3 wire thermostat with a programmable honey well RTH6300B. I am unable to match the wires. The wire coming out of the wall are stripped red , stripped blue and white. The old set up is R- Red White - Y Blue - W. The heating system is gas with steam....

5-wire thermostat - LOST a few wire labels. HELP! [ 2 Answers ]

I am installing a programmable thermostat (upgrading from a previous programmable that wasn't to our liking. When taking the old thermostat off, I noticed 4 of the 5 wires were labelled. That's a good thing. HOWEVER, when I took the old baseplate off, 2 of the labels fell off (not sure from...

Wiring a 2 wire thermostat to a 4 wire system [ 1 Answers ]

I have a gas furnace equipped with central air.The compressor is shot in the AC unit,and I needed to replace the thermostat so I bought a heating only thermostat.I have the blower and the w wires together on the w terminal designation and the rh on the r terminal designation, and I have the y wire...


View more questions Search