Ask Experts Questions for FREE Help !
Ask
    SThumm's Avatar
    SThumm Posts: 1, Reputation: 1
    New Member
     
    #1

    Nov 5, 2007, 06:52 PM
    Thermostat Changeout: from Aprilaire 8346 to a LUX TX9000TS (Wiring trouble)
    I would like to change from an Aprilaire 8346 Digital t-stat to a LUX TX9000TS but am having a bit a trouble determining whether they're compatible.

    The Aprilaire wiring scheme is as follows:

    C W2 R G Y O/B where in this application the O/B is an O.

    What wires (if possible) would go to what contacts on the LUX?

    The LUX wiring scheme is as follows:

    W Y G B O RC RH C (the RC and RH are jumpered out of the box)

    My system is to the best of my knowledge NOT multistage, I think in this application the W2 is for an E-Heat function.

    NOw to my Problem...

    Im not sure where to go from here knowing what little I know about my system... is it just a simple swap out from letter to letter. If so everything swaps nicely except the R to RC/RH, which contact should I connect the wire that was previously connected to an R contact.

    Any help that you folks could give would be appreciated. Thanks.

    Shawn
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Nov 6, 2007, 05:31 PM
    Just jumper RH and RC together

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Wiring Aprilaire 700 Humidifier [ 6 Answers ]

I am installing a Aprilaire 700 Humidifier on a Goodman GMNT gas furnace the Furnace control board is a white rogers 50T 35-730 it has separate hum 24v Terminal and hum 120v terminal the Aprilaire 700 Humidifier includes a built in 110v to 24v transformer which one should I connect it to and also...

NO HEAT! Janitrol heat pump and AC system. Changing to Lux Thermostat. Wiring issue. [ 11 Answers ]

I have a Janitrol A/C and heat pump system. I replaced the thermostat with a Lux T9000LC The A/C works fine, but the heater does not. I have it wired as follows: G - Green Y - Yellow W - White RH - Pink B -

Honeywell wiring different from old thermostat wiring [ 2 Answers ]

I purchased a non-programmable digital thermostat to replace an analog thermostat with wiring red, white yellow and black. How do I match the wiring? HELP!!

Lux TX9000TX Thermostat - heater blower won't come on [ 2 Answers ]

I recently changed from a manual-digital thermostat to a Lux TX9000TS electronic thermostat. All functions (Air, Heat & Fan) worked with the old thermostat. With the TX9000TS the air works fine and the fan blows in fan only mode. In the heat mode the Gibson air handler in the basement clicks and...

Aprilaire Communicating Thermostat vs Lennox GHR32V Furnace [ 8 Answers ]

Lennox furnace doesn't work after changing out thermostat to an Aprilaire model 8870 communicating thermostat. Have triple checked the most obvious and wiring at both ends. Furnace powers up but will not ignite. Have changed out the new Aprilaire for another exact model. Still no luck! ...